Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

473 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
Dynamic Risk Estimation of Adverse Events in Ambulatory LVAD Patients: A MOMENTUM 3 Analysis.
Shah P, Sayer G, Sinha SS, Kanwar MK, Cowger JA, Pagani FD, Nayak A, Mehra MR, Cleveland JC Jr, Psotka MA, Singh R, Desai SS, Lu Q, Hu Y, Connolly A, Kormos RL, Uriel N. Shah P, et al. Among authors: uriel n. JACC Heart Fail. 2024 Nov;12(11):1898-1912. doi: 10.1016/j.jchf.2024.05.018. Epub 2024 Jul 24. JACC Heart Fail. 2024. PMID: 39066758
Left Ventricular Decompression During Speed Optimization Ramps in Patients Supported by Continuous-Flow Left Ventricular Assist Devices: Device-Specific Performance Characteristics and Impact on Diagnostic Algorithms.
Uriel N, Levin AP, Sayer GT, Mody KP, Thomas SS, Adatya S, Yuzefpolskaya M, Garan AR, Breskin A, Takayama H, Colombo PC, Naka Y, Burkhoff D, Jorde UP. Uriel N, et al. J Card Fail. 2015 Oct;21(10):785-91. doi: 10.1016/j.cardfail.2015.06.010. Epub 2015 Jun 25. J Card Fail. 2015. PMID: 26117282
Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System: A Novel Approach Using Log File Analysis.
Jorde UP, Aaronson KD, Najjar SS, Pagani FD, Hayward C, Zimpfer D, Schlöglhofer T, Pham DT, Goldstein DJ, Leadley K, Chow MJ, Brown MC, Uriel N. Jorde UP, et al. Among authors: uriel n. JACC Heart Fail. 2015 Nov;3(11):849-56. doi: 10.1016/j.jchf.2015.06.015. Epub 2015 Oct 7. JACC Heart Fail. 2015. PMID: 26454842 Free article.
Hemodynamics of Mechanical Circulatory Support.
Burkhoff D, Sayer G, Doshi D, Uriel N. Burkhoff D, et al. Among authors: uriel n. J Am Coll Cardiol. 2015 Dec 15;66(23):2663-2674. doi: 10.1016/j.jacc.2015.10.017. J Am Coll Cardiol. 2015. PMID: 26670067 Free article. Review.
Accurate Quantification Methods for Aortic Insufficiency Severity in Patients With LVAD: Role of Diastolic Flow Acceleration and Systolic-to-Diastolic Peak Velocity Ratio of Outflow Cannula.
Grinstein J, Kruse E, Sayer G, Fedson S, Kim GH, Jorde UP, Juricek C, Ota T, Jeevanandam V, Lang RM, Uriel N. Grinstein J, et al. Among authors: uriel n. JACC Cardiovasc Imaging. 2016 Jun;9(6):641-51. doi: 10.1016/j.jcmg.2015.06.020. Epub 2015 Dec 9. JACC Cardiovasc Imaging. 2016. PMID: 26684975 Free article.
Hemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices.
Uriel N, Sayer G, Addetia K, Fedson S, Kim GH, Rodgers D, Kruse E, Collins K, Adatya S, Sarswat N, Jorde UP, Juricek C, Ota T, Jeevanandam V, Burkhoff D, Lang RM. Uriel N, et al. JACC Heart Fail. 2016 Mar;4(3):208-17. doi: 10.1016/j.jchf.2015.10.001. Epub 2015 Dec 30. JACC Heart Fail. 2016. PMID: 26746378 Free article.
Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol.
Heatley G, Sood P, Goldstein D, Uriel N, Cleveland J, Middlebrook D, Mehra MR; MOMENTUM 3 Investigators. Heatley G, et al. Among authors: uriel n. J Heart Lung Transplant. 2016 Apr;35(4):528-36. doi: 10.1016/j.healun.2016.01.021. Epub 2016 Jan 30. J Heart Lung Transplant. 2016. PMID: 27044532 Free article. Review.
473 results