Zum Hauptinhalt springen

Showing 1–9 of 9 results for author: Alyari, M

.
  1. arXiv:2406.11937  [pdf, other

    physics.ins-det hep-ex physics.data-an

    Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

    Authors: M. Aamir, B. Acar, G. Adamov, T. Adams, C. Adloff, S. Afanasiev, C. Agrawal, C. Agrawal, A. Ahmad, H. A. Ahmed, S. Akbar, N. Akchurin, B. Akgul, B. Akgun, R. O. Akpinar, E. Aktas, A. AlKadhim, V. Alexakhin, J. Alimena, J. Alison, A. Alpana, W. Alshehri, P. Alvarez Dominguez, M. Alyari, C. Amendola , et al. (550 additional authors not shown)

    Abstract: A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr… ▽ More

    Submitted 30 June, 2024; v1 submitted 17 June, 2024; originally announced June 2024.

    Comments: Prepared for submission to JINST

  2. arXiv:2211.04740  [pdf, other

    physics.ins-det

    Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A. Alpana, M. Alyari, I. Andreev, U. Aras, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Banerjee, P. DeBarbaro, P. Bargassa, D. Barney, F. Beaudette , et al. (435 additional authors not shown)

    Abstract: The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med… ▽ More

    Submitted 27 May, 2023; v1 submitted 9 November, 2022; originally announced November 2022.

    Comments: Accepted for publication by JINST

  3. arXiv:2111.06855  [pdf, other

    physics.ins-det hep-ex

    Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, F. Alam Khan, M. Alhusseini, J. Alison, A. Alpana, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Bannerjee, P. Bargassa, D. Barney, F. Beaudette , et al. (364 additional authors not shown)

    Abstract: The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu… ▽ More

    Submitted 31 March, 2022; v1 submitted 12 November, 2021; originally announced November 2021.

  4. arXiv:2012.06336  [pdf, other

    physics.ins-det hep-ex

    Construction and commissioning of CMS CE prototype silicon modules

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul… ▽ More

    Submitted 10 December, 2020; originally announced December 2020.

    Comments: 35 pages, submitted to JINST

  5. arXiv:2012.03876  [pdf, other

    physics.ins-det hep-ex

    The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca… ▽ More

    Submitted 8 December, 2020; v1 submitted 7 December, 2020; originally announced December 2020.

  6. arXiv:2006.04888  [pdf, other

    physics.ins-det hep-ex

    200 mm Sensor Development Using Bonded Wafers

    Authors: M. Alyari, R. Bradford, M. Campanella, P. Camporeale, R. Demina, J. Everts, Z. Gecse, R. Halenza, U. Heintz, S. Holland, S. Hong, S. Korjenevski, A. Lampis, R. Lipton, R. Patti, J. Segal, K. W. Shin

    Abstract: Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to $\> 200\ m^2$ for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than $200\ m^2$ of silicon and the CMS Hi… ▽ More

    Submitted 2 September, 2020; v1 submitted 8 June, 2020; originally announced June 2020.

    Comments: 11 pages

    Report number: FERMILAB-PUB-20-223-CMS-E

  7. Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

    Authors: N. Akchurin, P. Almeida, G. Altopp, M. Alyari, T. Bergauer, E. Brondolin, B. Burkle, W. D. Frey, Z. Gecse, U. Heintz, N. Hinton, V. Kuryatkov, R. Lipton, M. Mannelli, T. Mengke, P. Paulitsch, T. Peltola, F. Pitters, E. Sicking, E. Spencer, M. Tripathi, M. Vicente Barreto Pinto, J. Voelker, Z. Wang, R. Yohay

    Abstract: The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, an… ▽ More

    Submitted 4 August, 2020; v1 submitted 16 May, 2020; originally announced May 2020.

    Comments: 36 pages, 34 figures

  8. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  9. Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023