-
Electric Fields in Liquid Water Irradiated with Protons at Ultrahigh Dose Rates
Authors:
F. Gobet,
P. Barberet,
M. -H. Delville,
G. Devès,
T. Guérin,
R. Liénard,
H. N. Tran,
C. Vecco-Garda,
A. Würger,
S. Zein,
H. Seznec
Abstract:
We study the effects of irradiating water with 3 MeV protons at high doses by observing the motion of charged polystyrene beads outside the proton beam. By single-particle tracking, we measure a radial velocity of the order of microns per second. Combining electrokinetic theory with simulations of the beam-generated reaction products and their outward diffusion, we find that the bead motion is due…
▽ More
We study the effects of irradiating water with 3 MeV protons at high doses by observing the motion of charged polystyrene beads outside the proton beam. By single-particle tracking, we measure a radial velocity of the order of microns per second. Combining electrokinetic theory with simulations of the beam-generated reaction products and their outward diffusion, we find that the bead motion is due to electrophoresis in the electric field induced by the mobility contrast of cations and anions. This work sheds light on the perturbation of biological systems by high-dose radiations and paves the way for the manipulation of colloid or macromolecular dispersions by radiation-induced diffusiophoresis.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
X-ray photons produced from a plasma-cathode electron beam for radiation biology applications
Authors:
F. Gobet,
P. Barberet,
L. Courtois,
G. Deves,
J. Gardelle,
S. Leblanc,
L. Plawinski,
H. Seznec
Abstract:
A compact low-energy and high-intensity X-ray source for radiation biology applications is presented. A laser-induced plasma moves inside a 30 kV diode and produces a beam of 10$^{14}$ electrons at the anode location. An aluminum foil converts a part of the energy of these electrons into X-ray photons which are characterized using filtered imaging plates. The dose that would be deposited by these…
▽ More
A compact low-energy and high-intensity X-ray source for radiation biology applications is presented. A laser-induced plasma moves inside a 30 kV diode and produces a beam of 10$^{14}$ electrons at the anode location. An aluminum foil converts a part of the energy of these electrons into X-ray photons which are characterized using filtered imaging plates. The dose that would be deposited by these X-ray photons in C. elegans larvae is calculated from Geant4 simulations. It can be set to a value ranging between 10 $μ$Gy and 10 mGy per laser shot by simply changing the aluminum foil thickness and the diode voltage. Therefore, this versatile and compact X-ray source opens a new path to explore the radiation effects induced by dose rates varying over several orders of magnitude.
△ Less
Submitted 30 January, 2021;
originally announced February 2021.
-
Simulation of cellular irradiation with the CENBG microbeam line using GEANT4
Authors:
S. Incerti,
Ph. Barberet,
R. Villeneuve,
P. Aguer,
E. Gontier,
C. Michelet-Habchi,
Ph. Moretto,
D. T. Nguyen,
T. Pouthier,
R. W. Smith
Abstract:
Light-ion microbeams provide a unique opportunity to irradiate biological samples at the cellular level and to investigate radiobiological effects at low doses of high LET ionising radiation. Since 1998 a single-ion irradiation facility has been developed on the focused horizontal microbeam line of the CENBG 3.5 MV Van de Graaff accelerator. This setup delivers in air single protons and alpha pa…
▽ More
Light-ion microbeams provide a unique opportunity to irradiate biological samples at the cellular level and to investigate radiobiological effects at low doses of high LET ionising radiation. Since 1998 a single-ion irradiation facility has been developed on the focused horizontal microbeam line of the CENBG 3.5 MV Van de Graaff accelerator. This setup delivers in air single protons and alpha particles of a few MeV onto cultured cells, with a spatial resolution of a few microns, allowing subcellular targeting. In this paper, we present results from the use of the GEANT4 toolkit to simulate cellular irradiation with the CENBG microbeam line, from the entrance to the microprobe up to the cellular medium.
△ Less
Submitted 25 October, 2003;
originally announced October 2003.