-
MicroBundlePillarTrack: A Python package for automated segmentation, tracking, and analysis of pillar deflection in cardiac microbundles
Authors:
Hiba Kobeissi,
Xining Gao,
Samuel J. DePalma,
Jourdan K. Ewoldt,
Miranda C. Wang,
Shoshana L. Das,
Javiera Jilberto,
David Nordsletten,
Brendon M. Baker,
Christopher S. Chen,
Emma Lejeune
Abstract:
Movies of human induced pluripotent stem cell (hiPSC)-derived engineered cardiac tissue (microbundles) contain abundant information about structural and functional maturity. However, extracting these data in a reproducible and high-throughput manner remains a major challenge. Furthermore, it is not straightforward to make direct quantitative comparisons across the multiple in vitro experimental pl…
▽ More
Movies of human induced pluripotent stem cell (hiPSC)-derived engineered cardiac tissue (microbundles) contain abundant information about structural and functional maturity. However, extracting these data in a reproducible and high-throughput manner remains a major challenge. Furthermore, it is not straightforward to make direct quantitative comparisons across the multiple in vitro experimental platforms employed to fabricate these tissues. Here, we present "MicroBundlePillarTrack," an open-source optical flow-based package developed in Python to track the deflection of pillars in cardiac microbundles grown on experimental platforms with two different pillar designs ("Type 1" and "Type 2" design). Our software is able to automatically segment the pillars, track their displacements, and output time-dependent metrics for contractility analysis, including beating amplitude and rate, contractile force, and tissue stress. Because this software is fully automated, it will allow for both faster and more reproducible analyses of larger datasets and it will enable more reliable cross-platform comparisons as compared to existing approaches that require manual steps and are tailored to a specific experimental platform. To complement this open-source software, we share a dataset of 1,540 brightfield example movies on which we have tested our software. Through sharing this data and software, our goal is to directly enable quantitative comparisons across labs, and facilitate future collective progress via the biomedical engineering open-source data and software ecosystem.
△ Less
Submitted 15 August, 2024; v1 submitted 17 May, 2024;
originally announced May 2024.
-
MicroBundleCompute: Automated segmentation, tracking, and analysis of subdomain deformation in cardiac microbundles
Authors:
Hiba Kobeissi,
Javiera Jilberto,
M. Çağatay Karakan,
Xining Gao,
Samuel J. DePalma,
Shoshana L. Das,
Lani Quach,
Jonathan Urquia,
Brendon M. Baker,
Christopher S. Chen,
David Nordsletten,
Emma Lejeune
Abstract:
Advancing human induced pluripotent stem cell derived cardiomyocyte (hiPSC-CM) technology will lead to significant progress ranging from disease modeling, to drug discovery, to regenerative tissue engineering. Yet, alongside these potential opportunities comes a critical challenge: attaining mature hiPSC-CM tissues. At present, there are multiple techniques to promote maturity of hiPSC-CMs includi…
▽ More
Advancing human induced pluripotent stem cell derived cardiomyocyte (hiPSC-CM) technology will lead to significant progress ranging from disease modeling, to drug discovery, to regenerative tissue engineering. Yet, alongside these potential opportunities comes a critical challenge: attaining mature hiPSC-CM tissues. At present, there are multiple techniques to promote maturity of hiPSC-CMs including physical platforms and cell culture protocols. However, when it comes to making quantitative comparisons of functional behavior, there are limited options for reliably and reproducibly computing functional metrics that are suitable for direct cross-system comparison. In addition, the current standard functional metrics obtained from time-lapse images of cardiac microbundle contraction reported in the field (i.e., post forces, average tissue stress) do not take full advantage of the available information present in these data (i.e., full-field tissue displacements and strains). Thus, we present "MicroBundleCompute," a computational framework for automatic quantification of morphology-based mechanical metrics from movies of cardiac microbundles. Briefly, this computational framework offers tools for automatic tissue segmentation, tracking, and analysis of brightfield and phase contrast movies of beating cardiac microbundles. It is straightforward to implement, requires little to no parameter tuning, and runs quickly on a personal computer. In this paper, we describe the methods underlying this computational framework, show the results of our extensive validation studies, and demonstrate the utility of exploring heterogeneous tissue deformations and strains as functional metrics. With this manuscript, we disseminate "MicroBundleCompute" as an open-source computational tool with the aim of making automated quantitative analysis of beating cardiac microbundles more accessible to the community.
△ Less
Submitted 20 February, 2024; v1 submitted 8 August, 2023;
originally announced August 2023.
-
Models for membrane curvature sensing of curvature generating proteins
Authors:
T. V. Sachin Krishnan,
Sovan L. Das,
P. B. Sunil Kumar
Abstract:
The curvature sensitive localization of proteins on membranes is vital for many cell biological processes. Coarse-grained models are routinely employed to study the curvature sensing phenomena and membrane morphology at the length scale of few micrometers. Two prevalent phenomenological models exist for modeling experimental observations of curvature sensing, (1) the spontaneous curvature model an…
▽ More
The curvature sensitive localization of proteins on membranes is vital for many cell biological processes. Coarse-grained models are routinely employed to study the curvature sensing phenomena and membrane morphology at the length scale of few micrometers. Two prevalent phenomenological models exist for modeling experimental observations of curvature sensing, (1) the spontaneous curvature model and (2) the curvature mismatch model, which differ in their treatment of the change in elastic energy due to the binding of proteins on the membrane. In this work, the prediction of sensing and generation behaviour, by these two models, are investigated using analytical calculations as well as Dynamic Triangulation Monte Carlo simulations of quasi-spherical vesicles. While the spontaneous curvature model yields a monotonically decreasing sensing curve as a function of vesicle radius, the curvature mismatch model results in a non-monotonic sensing curve. We highlight the main differences in the interpretation of the protein-related parameters in the two models. We further propose that the spontaneous curvature model is appropriate for modeling peripheral proteins employing the hydrophobic insertion mechanism, with minimal modification of membrane rigidity, while the curvature mismatch model is appropriate for modeling curvature generation using scaffolding mechanism where there is significant stiffening of the membrane due to protein binding.
△ Less
Submitted 21 October, 2019;
originally announced October 2019.