-
A Biomechatronic Approach to Evaluating the Security of Wearable Devices in the Internet of Medical Things
Authors:
Yas Vaseghi,
Behnaz Behara,
Mehdi Delrobaei
Abstract:
The Internet of Medical Things (IoMT) has the potential to revolutionize healthcare by reducing human error and improving patient health. For instance, wearable smart infusion pumps can accurately administer medication and integrate with electronic health records. These pumps can alert healthcare professionals or remote servers when an operation fails, preventing distressing incidents. However, as…
▽ More
The Internet of Medical Things (IoMT) has the potential to revolutionize healthcare by reducing human error and improving patient health. For instance, wearable smart infusion pumps can accurately administer medication and integrate with electronic health records. These pumps can alert healthcare professionals or remote servers when an operation fails, preventing distressing incidents. However, as the number of connected medical devices increases, so does the risk of cyber threats. Wearable medication devices based on IoT attached to patients' bodies are particularly vulnerable to significant cyber threats. Since they are connected to the internet, these devices can be exposed to potential harm, which can disrupt or degrade device performance and harm patients. Therefore, it is crucial to establish secure data authentication for internet-connected medical devices to ensure patient safety and well-being. It is also important to note that the wearability option of such devices might downgrade the computational resources, making them more susceptible to security risks. We propose implementing a security approach for a wearable infusion pump to mitigate cyber threats. We evaluated the proposed architecture with 20, 50, and 100 users for 10 minutes and repeated the evaluation 10 times with two infusion settings, each repeated five times. The desired volumes and rates for the two settings were 2 ml and 4 ml/hr and 5 ml and 5 ml/hr, respectively. The maximum error in infusion rate was measured to be 2.5%. We discuss the practical challenges of implementing such a security-enabled device and suggest initial solutions.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
A Review on Recent Energy Harvesting Methods for Increasing Battery Efficiency in WBANs
Authors:
Hossein Yektamoghadam,
Amirhossein Nikoofard,
Fatemeh Pourhanifeh Doust,
Mehdi Delrobaei
Abstract:
Today, technology development has led humans to employ wearable and implantable devices for biomedical applications. An important research issue in this field is the wireless body area networks (WBANs), which focus on such devices. In WBAN, using batteries as the only energy supply is a significant challenge, especially in medical applications. Charging the batteries is a problem for patients who…
▽ More
Today, technology development has led humans to employ wearable and implantable devices for biomedical applications. An important research issue in this field is the wireless body area networks (WBANs), which focus on such devices. In WBAN, using batteries as the only energy supply is a significant challenge, especially in medical applications. Charging the batteries is a problem for patients who use WBAN. Replacing the battery is not very difficult for wearable devices, but implantable devices have different conditions. The use of batteries in implantable devices has many problems, including pain and costs due to surgery, mental stress, and lack of comfort. Batteries' life depends on their type, operation, the patient's medical condition, and other factors. This paper reviews recent energy harvesting methods for battery recharge in WBAN's sensors. Moreover, we provide future research directions on energy harvesting methods in WBANs. Therefore, active research fields such as reinforcement learning (RL) and distributed optimization in WBAN applications were investigated. We strongly believe that these insights will aid in studying and developing a new generation of rechargeable sensors in WBANs for fellow researchers.
△ Less
Submitted 12 January, 2024;
originally announced February 2024.
-
Towards Cognitive Load Assessment Using Electrooculography Measures
Authors:
Arash Abbasi Larki,
Akram Shojaei,
Mehdi Delrobaei
Abstract:
Cognitive load assessment is crucial for understanding human performance in various domains. This study investigates the impact of different task conditions and time constraints on cognitive load using multiple measures, including subjective evaluations, performance metrics, and physiological eye-tracking data. Fifteen participants completed a series of primary and secondary tasks with different t…
▽ More
Cognitive load assessment is crucial for understanding human performance in various domains. This study investigates the impact of different task conditions and time constraints on cognitive load using multiple measures, including subjective evaluations, performance metrics, and physiological eye-tracking data. Fifteen participants completed a series of primary and secondary tasks with different time limits. The NASA-TLX questionnaire, reaction time, inverse efficiency score, and eye-related features (blink, saccade, and fixation frequency) were utilized to assess cognitive load. The study results show significant differences in the level of cognitive load required for different tasks and when under time constraints. The study also found that there was a positive correlation (r = 0.331, p = 0.014) between how often participants blinked their eyes and the level of cognitive load required but a negative correlation (r = -0.290, p = 0.032) between how often participants made quick eye movements (saccades) and the level of cognitive load required. Additionally, the analysis revealed a significant negative correlation (r = -0.347, p = 0.009) and (r = -0.370, p = 0.005) between fixation and saccade frequencies under time constraints.
△ Less
Submitted 18 December, 2023;
originally announced December 2023.
-
Preliminary Guidelines for Electrode Positioning in Noninvasive Deep Brain Stimulation via Temporally Interfering Electric Fields
Authors:
Mobina Zibandepour,
Akram Shojaei,
Arash Abbasi Larki,
Mehdi Delrobaei
Abstract:
Advancements in neurosurgical robotics have improved medical procedures, particularly deep brain stimulation, where robots combine human and machine intelligence to precisely implant electrodes in the brain. While effective, this procedure carries risks and side effects. Noninvasive deep brain stimulation (NIDBS) offers promise by making brain stimulation safer, more affordable, and accessible. Ho…
▽ More
Advancements in neurosurgical robotics have improved medical procedures, particularly deep brain stimulation, where robots combine human and machine intelligence to precisely implant electrodes in the brain. While effective, this procedure carries risks and side effects. Noninvasive deep brain stimulation (NIDBS) offers promise by making brain stimulation safer, more affordable, and accessible. However, NIDBS lacks guidelines for electrode placement. This study explores adapting robotic principles to enhance the accuracy of NIDBS targeting and provides preliminary guidelines for transcranial electrode placement. Safety is also emphasized, ensuring a balance between therapeutic effectiveness and patient safety by maintaining electric fields within safe limits.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Towards Evaluating the Security of Wearable Devices in the Internet of Medical Things
Authors:
Yas Vaseghi,
Behnaz Behara,
Mehdi Delrobaei
Abstract:
The Internet of Medical Things (IoMT) offers a promising solution to improve patient health and reduce human error. Wearable smart infusion pumps that accurately administer medication and integrate with electronic health records are an example of technology that can improve healthcare. They can even alert healthcare professionals or remote servers during operational failure, preventing distressing…
▽ More
The Internet of Medical Things (IoMT) offers a promising solution to improve patient health and reduce human error. Wearable smart infusion pumps that accurately administer medication and integrate with electronic health records are an example of technology that can improve healthcare. They can even alert healthcare professionals or remote servers during operational failure, preventing distressing incidents. However, as the number of connected medical devices increases, the risk of cyber threats also increases. Wearable medication devices based on IoT attached to patients' bodies are prone to significant cyber threats. Being connected to the Internet exposes these devices to potential harm, which could disrupt or degrade device performance and harm patients. To ensure patient safety and well-being, it is crucial to establish secure data authentication for internet-connected medical devices. It is also important to note that the wearability option of such devices might downgrade the computational resources, making them more susceptible to security risks. This paper implements a security approach to a wearable infusion pump. We discuss practical challenges in implementing security-enabled devices and propose initial solutions to mitigate cyber threats.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Overcoming Cognitive Distraction and Measurement Noise: Strategies for Humans and Engineering Systems
Authors:
Mehdi Delrobaei
Abstract:
Cognitive distraction and measurement noise are two distinct factors that significantly impact the performance of humans and engineering systems. Cognitive distraction occurs when an individual's attention is diverted from a task, while measurement noise refers to the random variation that can occur in system measurements. Although humans and engineering systems employ different methods to overcom…
▽ More
Cognitive distraction and measurement noise are two distinct factors that significantly impact the performance of humans and engineering systems. Cognitive distraction occurs when an individual's attention is diverted from a task, while measurement noise refers to the random variation that can occur in system measurements. Although humans and engineering systems employ different methods to overcome these obstacles, the ultimate goal is to achieve optimal performance. An intriguing question arises: what are the similarities and differences between using the term "noise" in engineering and cognitive psychology? Additionally, it is worthwhile to explore whether the human brain and engineering control systems use similar or different approaches to attenuate noise. While this article does not provide a definitive answer, it emphasizes the importance of addressing this question and encourages further investigation.
△ Less
Submitted 11 December, 2023;
originally announced December 2023.
-
A Cost-Effective Test Bench for Evaluating Safe Human-Robot Interaction in Mobile Robotics
Authors:
Atefeh Fereydooni,
Armin Azarakhsh,
Ayda Shafiei,
Hesam Zandi,
Mehdi Delrobaei
Abstract:
Safety concerns have risen as robots become more integrated into our daily lives and continue to interact closely with humans. One of the most crucial safety priorities is preventing collisions between robots and people walking nearby. Despite developing various algorithms to address this issue, evaluating their effectiveness on a cost-effective test bench remains a significant challenge. In this…
▽ More
Safety concerns have risen as robots become more integrated into our daily lives and continue to interact closely with humans. One of the most crucial safety priorities is preventing collisions between robots and people walking nearby. Despite developing various algorithms to address this issue, evaluating their effectiveness on a cost-effective test bench remains a significant challenge. In this work, we propose a solution by introducing a simple yet functional platform that enables researchers and developers to assess how humans interact with mobile robots. This platform is designed to provide a quick yet accurate evaluation of the performance of safe interaction algorithms and make informed decisions for future development. The platform's features and structure are detailed, along with the initial testing results using two preliminary algorithms. The results obtained from the evaluation were consistent with theoretical calculations, demonstrating its effectiveness in assessing human-robot interaction. Our solution provides a preliminary yet reliable approach to ensure the safety of both robots and humans in their daily interactions.
△ Less
Submitted 7 December, 2023;
originally announced December 2023.
-
Towards Blockchain-based Remote Management Systems for Patients with Movement Disorders
Authors:
Behnaz Behara,
Mehdi Delrobaei
Abstract:
Secure storage and sharing of patients' medical data over the Internet are part of the challenges for emerging healthcare systems. The use of blockchain technology in medical Internet of things systems can be considered a safe and novel solution to overcome such challenges. Patients with movement disorders require multi-disciplinary management and must continuously receive medical care from a spec…
▽ More
Secure storage and sharing of patients' medical data over the Internet are part of the challenges for emerging healthcare systems. The use of blockchain technology in medical Internet of things systems can be considered a safe and novel solution to overcome such challenges. Patients with movement disorders require multi-disciplinary management and must continuously receive medical care from a specialist. Due to the increasing costs of face-to-face treatment, especially during the pandemic, patients would highly benefit from remote monitoring and management. The proposed work presents a model for blockchain-based remote management systems for patients with movement disorders, especially those with Parkinson's disease. The model ensures a high level of integrity and decreases the security risks of medical data sharing.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Evaluating Attentional Impulsivity: A Biomechatronic Approach
Authors:
Fateme Zare,
Paniz Sedighi,
Mehdi Delrobaei
Abstract:
Executive function, also known as executive control, is a multifaceted construct encompassing several cognitive abilities, including working memory, attention, impulse control, and cognitive flexibility. To accurately measure executive functioning skills, it is necessary to develop assessment tools and strategies that can quantify the behaviors associated with cognitive control. Impulsivity, a ran…
▽ More
Executive function, also known as executive control, is a multifaceted construct encompassing several cognitive abilities, including working memory, attention, impulse control, and cognitive flexibility. To accurately measure executive functioning skills, it is necessary to develop assessment tools and strategies that can quantify the behaviors associated with cognitive control. Impulsivity, a range of cognitive control deficits, is typically evaluated using conventional neuropsychological tests. However, this study proposes a biomechatronic approach to assess impulsivity as a behavioral construct, in line with traditional neuropsychological assessments. The study involved thirty-four healthy adults who completed the Barratt Impulsiveness Scale (BIS-11) as an initial step. A low-cost biomechatronic system was developed, and an approach based on standard neuropsychological tests, including the trail-making test and serial subtraction-by-seven, was used to evaluate impulsivity. Three tests were conducted: WTMT-A (numbers only), WTMT-B (numbers and letters), and a dual-task of WTMT-A and serial subtraction-by-seven. The preliminary findings suggest that the proposed instrument and experiments successfully generated an attentional impulsivity score and differentiated between participants with high and low attentional impulsivity.
△ Less
Submitted 22 July, 2023; v1 submitted 11 July, 2023;
originally announced July 2023.
-
Driver Drowsiness Detection with Commercial EEG Headsets
Authors:
Qazal Rezaee,
Mehdi Delrobaei,
Ashkan Giveki,
Nasireh Dayarian,
Sahar Javaher Haghighi
Abstract:
Driver Drowsiness is one of the leading causes of road accidents. Electroencephalography (EEG) is highly affected by drowsiness; hence, EEG-based methods detect drowsiness with the highest accuracy. Developments in manufacturing dry electrodes and headsets have made recording EEG more convenient. Vehicle-based features used for detecting drowsiness are easy to capture but do not have the best perf…
▽ More
Driver Drowsiness is one of the leading causes of road accidents. Electroencephalography (EEG) is highly affected by drowsiness; hence, EEG-based methods detect drowsiness with the highest accuracy. Developments in manufacturing dry electrodes and headsets have made recording EEG more convenient. Vehicle-based features used for detecting drowsiness are easy to capture but do not have the best performance. In this paper, we investigated the performance of EEG signals recorded in 4 channels with commercial headsets against the vehicle-based technique in drowsiness detection. We recorded EEG signals of 50 volunteers driving a simulator in drowsy and alert states by commercial devices. The observer rating of the drowsiness method was used to determine the drowsiness level of the subjects. The meaningful separation of vehicle-based features, recorded by the simulator, and EEG-based features of the two states of drowsiness and alertness have been investigated. The comparison results indicated that the EEG-based features are separated with lower p-values than the vehicle-based ones in the two states. It is concluded that EEG headsets can be feasible alternatives with better performance compared to vehicle-based methods for detecting drowsiness.
△ Less
Submitted 26 March, 2023;
originally announced March 2023.
-
A Wearable RFID-Based Navigation System for the Visually Impaired
Authors:
Fateme Zare,
Paniz Sedighi,
Mehdi Delrobaei
Abstract:
Recent studies have focused on developing advanced assistive devices to help blind or visually impaired people. Navigation is challenging for this community; however, developing a simple yet reliable navigation system is still an unmet need. This study targets the navigation problem and proposes a wearable assistive system. We developed a smart glove and shoe set based on radio-frequency identific…
▽ More
Recent studies have focused on developing advanced assistive devices to help blind or visually impaired people. Navigation is challenging for this community; however, developing a simple yet reliable navigation system is still an unmet need. This study targets the navigation problem and proposes a wearable assistive system. We developed a smart glove and shoe set based on radio-frequency identification technology to assist visually impaired people with navigation and orientation in indoor environments. The system enables the user to find the directions through audio feedback. To evaluate the device's performance, we designed a simple experimental setup. The proposed system has a simple structure and can be personalized according to the user's requirements. The results identified that the platform is reliable, power efficient, and accurate enough for indoor navigation.
△ Less
Submitted 26 March, 2023;
originally announced March 2023.
-
Evaluating the Possibility of Integrating Augmented Reality and Internet of Things Technologies to Help Patients with Alzheimer's Disease
Authors:
Fatemeh Ghorbani,
Mohammad Kia,
Mehdi Delrobaei,
Quazi Rahman
Abstract:
People suffering from Alzheimer's disease (AD) and their caregivers seek different approaches to cope with memory loss. Although AD patients want to live independently, they often need help from caregivers. In this situation, caregivers may attach notes on every single object or take out the contents of a drawer to make them visible before leaving the patient alone at home. This study reports prel…
▽ More
People suffering from Alzheimer's disease (AD) and their caregivers seek different approaches to cope with memory loss. Although AD patients want to live independently, they often need help from caregivers. In this situation, caregivers may attach notes on every single object or take out the contents of a drawer to make them visible before leaving the patient alone at home. This study reports preliminary results on an Ambient Assisted Living (AAL) real-time system, achieved through the Internet of Things (IoT) and Augmented Reality (AR) concepts, aimed at helping people suffering from AD. The system has two main sections: the smartphone or windows application allows caregivers to monitor patients' status at home and be notified if patients are at risk. The second part allows patients to use smart glasses to recognize QR codes in the environment and receive information related to tags in the form of audio, text, or three-dimensional image. This work presents preliminary results and investigates the possibility of implementing such a system.
△ Less
Submitted 20 January, 2023;
originally announced January 2023.
-
Towards an Intelligent Assistive System Based on Augmented Reality and Serious Games
Authors:
Fatemeh Ghorbani,
Mahsa Farshi Taghavi,
Mehdi Delrobaei
Abstract:
Age-related cognitive impairment is generally characterized by gradual memory loss and decision-making difficulties. The aim of this study is to investigate multi level support and suggest relevant helping means for the elderly with mild cognitive impairment as well as their caregivers as the primary end-users. This work reports preliminary results on an intelligent assistive system, achieved thro…
▽ More
Age-related cognitive impairment is generally characterized by gradual memory loss and decision-making difficulties. The aim of this study is to investigate multi level support and suggest relevant helping means for the elderly with mild cognitive impairment as well as their caregivers as the primary end-users. This work reports preliminary results on an intelligent assistive system, achieved through the integration of Internet of Things, augmented reality, and adaptive fuzzy decision-making methods. The proposed system operates in different modes, including automated and semi-automated modes. The former helps the user complete their daily life activities by showing augmented reality messages or making automatic changes; while the latter allows manual changes after the real-time assessment of the user's cognitive state based on the augmented reality serious game score. We have also evaluated the accuracy of the serious game score with 37 elderly participants and compared it with users' paper-based cognitive test results. We further noted that there is an acceptable correlation between the paper-based test and users' serious game scores. Moreover, we observed that the system response in the semi-automated mode causes less data loss compared with the automated mode, as the number of active devices decreases.
△ Less
Submitted 6 January, 2023;
originally announced January 2023.
-
An RFID-Based Assistive Glove to Help the Visually Impaired
Authors:
Paniz Sedighi,
Mohammad Hesam Norouzi,
Mehdi Delrobaei
Abstract:
Recent studies have focused on facilitating perception and outdoor navigation for people with blindness or some form of vision loss. However, a significant portion of these studies is centered around treatment and vision rehabilitation, leaving some immediate needs, such as interaction with the surrounding objects or recognizing colors and fine patterns without tactile feedback. This study targets…
▽ More
Recent studies have focused on facilitating perception and outdoor navigation for people with blindness or some form of vision loss. However, a significant portion of these studies is centered around treatment and vision rehabilitation, leaving some immediate needs, such as interaction with the surrounding objects or recognizing colors and fine patterns without tactile feedback. This study targets such needs and delivers a straightforward communication method using a wearable, unobtrusive device with the environment. We initially discuss the advantages and limitations of related works to draw out the best-fitting design concepts. Then, we introduce the potential for emerging technologies such as radio-frequency identification. We present the design details and the experimental results of an assistive glove to allow people with vision disabilities to interact with the environment more efficiently. Based on the collected data from 17 blind-folded healthy participants, the implemented system's success rate in identifying objects was about 96.32%. Overall, 70% of the users found the device very satisfactory.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Bio-Heat Transfer and Monte Carlo Measurement of Near-Infrared Transcranial Stimulation of Human Brain
Authors:
Faezeh Ibrahimi,
Mehdi Delrobaei
Abstract:
Transcranial photobiomodulation is an optical method for non-invasive brain stimulation. The method projects red and near-infrared light through the scalp within 600-1100 nm and low energy within the 1-20 J/cm2 range. Recent studies have been optimistic about replacing this method with pharmacotherapy and invasive brain stimulation. However, concerns and ambiguities exist regarding the light penet…
▽ More
Transcranial photobiomodulation is an optical method for non-invasive brain stimulation. The method projects red and near-infrared light through the scalp within 600-1100 nm and low energy within the 1-20 J/cm2 range. Recent studies have been optimistic about replacing this method with pharmacotherapy and invasive brain stimulation. However, concerns and ambiguities exist regarding the light penetration depth and possible thermal side effects. While the literature survey indicates that the skin temperature rises after experimental optical brain stimulation, inadequate evidence supports a safe increase in temperature or the amount of light penetration in the cortex. Therefore, we aimed to conduct a comprehensive study on the heat transfer of near-infrared stimulation for the human brain. Our research considers the transcranial photobiomodulation over the human brain model by projecting 810 nm light with 100 mW/cm2 power density to evaluate its thermal and optical effects using bioheat transfer and radiative transfer equation. Our results confirm that the near-infrared light spectrum has a small incremental impact on temperature and approximately penetrates 1 cm, reaching the cortex. A time-variant study of the heat transfer was also carried out to measure the temperature changes during optical stimulation.
△ Less
Submitted 9 December, 2022; v1 submitted 7 December, 2022;
originally announced December 2022.