Development and validation of an artificial intelligence model to accurately predict spinopelvic parameters
Authors:
Edward S. Harake,
Joseph R. Linzey,
Cheng Jiang,
Rushikesh S. Joshi,
Mark M. Zaki,
Jaes C. Jones,
Siri S. Khalsa,
John H. Lee,
Zachary Wilseck,
Jacob R. Joseph,
Todd C. Hollon,
Paul Park
Abstract:
Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry re…
▽ More
Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry requirements. This study presents a novel artificial intelligence (AI) tool called SpinePose that automatically predicts spinopelvic parameters with high accuracy without the need for manual entry.
Methods. SpinePose was trained and validated on 761 sagittal whole-spine X-rays to predict sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), lumbar lordosis (LL), T1-pelvic angle (T1PA), and L1-pelvic angle (L1PA). A separate test set of 40 X-rays was labeled by 4 reviewers, including fellowship-trained spine surgeons and a fellowship-trained radiologist with neuroradiology subspecialty certification. Median errors relative to the most senior reviewer were calculated to determine model accuracy on test images. Intraclass correlation coefficients (ICC) were used to assess inter-rater reliability.
Results. SpinePose exhibited the following median (interquartile range) parameter errors: SVA: 2.2(2.3)mm, p=0.93; PT: 1.3(1.2)°, p=0.48; SS: 1.7(2.2)°, p=0.64; PI: 2.2(2.1)°, p=0.24; LL: 2.6(4.0)°, p=0.89; T1PA: 1.1(0.9)°, p=0.42; and L1PA: 1.4(1.6)°, p=0.49. Model predictions also exhibited excellent reliability at all parameters (ICC: 0.91-1.0).
Conclusions. SpinePose accurately predicted spinopelvic parameters with excellent reliability comparable to fellowship-trained spine surgeons and neuroradiologists. Utilization of predictive AI tools in spinal imaging can substantially aid in patient selection and surgical planning.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
Rapid Automated Analysis of Skull Base Tumor Specimens Using Intraoperative Optical Imaging and Artificial Intelligence
Authors:
Cheng Jiang,
Abhishek Bhattacharya,
Joseph Linzey,
Rushikesh S. Joshi,
Sung Jik Cha,
Sudharsan Srinivasan,
Daniel Alber,
Akhil Kondepudi,
Esteban Urias,
Balaji Pandian,
Wajd Al-Holou,
Steve Sullivan,
B. Gregory Thompson,
Jason Heth,
Chris Freudiger,
Siri Khalsa,
Donato Pacione,
John G. Golfinos,
Sandra Camelo-Piragua,
Daniel A. Orringer,
Honglak Lee,
Todd Hollon
Abstract:
Background: Accurate diagnosis of skull base tumors is essential for providing personalized surgical treatment strategies. Intraoperative diagnosis can be challenging due to tumor diversity and lack of intraoperative pathology resources.
Objective: To develop an independent and parallel intraoperative pathology workflow that can provide rapid and accurate skull base tumor diagnoses using label-f…
▽ More
Background: Accurate diagnosis of skull base tumors is essential for providing personalized surgical treatment strategies. Intraoperative diagnosis can be challenging due to tumor diversity and lack of intraoperative pathology resources.
Objective: To develop an independent and parallel intraoperative pathology workflow that can provide rapid and accurate skull base tumor diagnoses using label-free optical imaging and artificial intelligence.
Method: We used a fiber laser-based, label-free, non-consumptive, high-resolution microscopy method ($<$ 60 sec per 1 $\times$ 1 mm$^\text{2}$), called stimulated Raman histology (SRH), to image a consecutive, multicenter cohort of skull base tumor patients. SRH images were then used to train a convolutional neural network (CNN) model using three representation learning strategies: cross-entropy, self-supervised contrastive learning, and supervised contrastive learning. Our trained CNN models were tested on a held-out, multicenter SRH dataset.
Results: SRH was able to image the diagnostic features of both benign and malignant skull base tumors. Of the three representation learning strategies, supervised contrastive learning most effectively learned the distinctive and diagnostic SRH image features for each of the skull base tumor types. In our multicenter testing set, cross-entropy achieved an overall diagnostic accuracy of 91.5%, self-supervised contrastive learning 83.9%, and supervised contrastive learning 96.6%. Our trained model was able to identify tumor-normal margins and detect regions of microscopic tumor infiltration in whole-slide SRH images.
Conclusion: SRH with trained artificial intelligence models can provide rapid and accurate intraoperative analysis of skull base tumor specimens to inform surgical decision-making.
△ Less
Submitted 19 June, 2022; v1 submitted 7 August, 2021;
originally announced August 2021.