-
Error Compensation of Single-Qubit Gates in a Surface Electrode Ion Trap Using Composite Pulses
Authors:
Emily Mount,
Chingiz Kabytayev,
Stephen Crain,
Robin Harper,
So-Young Baek,
Geert Vrijsen,
Steven Flammia,
Kenneth R. Brown,
Peter Maunz,
Jungsang Kim
Abstract:
The fidelity of laser-driven quantum logic operations on trapped ion qubits tend to be lower than microwave-driven logic operations due to the difficulty of stabilizing the driving fields at the ion location. Through stabilization of the driving optical fields and use of composite pulse sequences, we demonstrate high fidelity single-qubit gates for the hyperfine qubit of a $^{171}\text{Yb}^+$ ion…
▽ More
The fidelity of laser-driven quantum logic operations on trapped ion qubits tend to be lower than microwave-driven logic operations due to the difficulty of stabilizing the driving fields at the ion location. Through stabilization of the driving optical fields and use of composite pulse sequences, we demonstrate high fidelity single-qubit gates for the hyperfine qubit of a $^{171}\text{Yb}^+$ ion trapped in a microfabricated surface electrode ion trap. Gate error is characterized using a randomized benchmarking protocol, and an average error per randomized Clifford group gate of $3.6(3)\times10^{-4}$ is measured. We also report experimental realization of palindromic pulse sequences that scale efficiently in sequence length.
△ Less
Submitted 20 July, 2015; v1 submitted 6 April, 2015;
originally announced April 2015.
-
Robustness of composite pulses to time-dependent control noise
Authors:
Chingiz Kabytayev,
Todd J. Green,
Kaveh Khodjasteh,
Michael J. Biercuk,
Lorenza Viola,
Kenneth R. Brown
Abstract:
We study the performance of composite pulses in the presence of time-varying control noise on a single qubit. These protocols, originally devised only to correct for static, systematic errors, are shown to be robust to time-dependent non-Markovian noise in the control field up to frequencies as high as ~10% of the Rabi frequency. Our study combines a generalized filter-function approach with asymp…
▽ More
We study the performance of composite pulses in the presence of time-varying control noise on a single qubit. These protocols, originally devised only to correct for static, systematic errors, are shown to be robust to time-dependent non-Markovian noise in the control field up to frequencies as high as ~10% of the Rabi frequency. Our study combines a generalized filter-function approach with asymptotic dc-limit calculations to give a simple analytic framework for error analysis applied to a number of composite-pulse sequences relevant to nuclear magnetic resonance as well as quantum information experiments. Results include examination of recently introduced concatenated composite pulses and dynamically corrected gates, demonstrating equivalent first-order suppression of time-dependent fluctuations in amplitude and/or detuning, as appropriate for the sequence in question. Our analytic results agree well with numerical simulations for realistic $1/f$ noise spectra with a roll-off to $1/f^2$, providing independent validation of our theoretical insights.
△ Less
Submitted 14 July, 2014; v1 submitted 20 February, 2014;
originally announced February 2014.
-
Comparison of ancilla preparation and measurement procedures for the Steane [[7,1,3]] code on a model ion trap quantum computer
Authors:
Yu Tomita,
Mauricio Gutiérrez,
Chingiz Kabytayev,
Kenneth R. Brown,
M. R. Hutsel,
A. P. Morris,
Kelly E. Stevens,
G. Mohler
Abstract:
We schedule the Steane [[7,1,3]] error correction on a model ion trap architecture with ballistic transport. We compare the level one error rates for syndrome extraction using the Shor method of ancilla prepared in verified cat states to the DiVincenzo-Aliferis method without verification. The study examines how the quantum error correction circuit latency and error vary with the number of availab…
▽ More
We schedule the Steane [[7,1,3]] error correction on a model ion trap architecture with ballistic transport. We compare the level one error rates for syndrome extraction using the Shor method of ancilla prepared in verified cat states to the DiVincenzo-Aliferis method without verification. The study examines how the quantum error correction circuit latency and error vary with the number of available ancilla and the choice of protocol for ancilla preparation and measurement. We find that with few exceptions the DiVincenzo-Aliferis method without cat state verification outperforms the standard Shor method. We also find that additional ancilla always reduces the latency but does not significantly change the error due to the high memory fidelity.
△ Less
Submitted 13 May, 2013; v1 submitted 2 May, 2013;
originally announced May 2013.