-
Josephson Parametric Amplifier based Quantum Noise Limited Amplifier Development for Axion Search Experiments in CAPP
Authors:
Sergey V. Uchaikin,
Jinmyeong Kim,
Caglar Kutlu,
Boris I. Ivanov,
Jinsu Kim,
Arjan F. van Loo,
Yasunobu Nakamura,
Saebyeok Ahn,
Seonjeong Oh,
Minsu Ko,
Yannis K. Semertzidis
Abstract:
This paper provides a comprehensive overview of the development of flux-driven Josephson Parametric Amplifiers (JPAs) as Quantum Noise Limited Amplifier for axion search experiments conducted at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science. It focuses on the characterization, and optimization of JPAs, which are crucial for achieving the highest sens…
▽ More
This paper provides a comprehensive overview of the development of flux-driven Josephson Parametric Amplifiers (JPAs) as Quantum Noise Limited Amplifier for axion search experiments conducted at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science. It focuses on the characterization, and optimization of JPAs, which are crucial for achieving the highest sensitivity in axion particle detection. We discuss various characterization techniques, methods for improving bandwidth, and the attainment of ultra-low noise temperatures. JPAs have emerged as indispensable tools in CAPPs axion search endeavors, playing a significant role in advancing our understanding of fundamental physics and unraveling the mysteries of the universe.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
The daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (38 additional authors not shown)
Abstract:
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities…
▽ More
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment
Authors:
Saebyeok Ahn,
JinMyeong Kim,
Boris I. Ivanov,
Ohjoon Kwon,
HeeSu Byun,
Arjan F. van Loo,
SeongTae Par,
Junu Jeong,
Soohyung Lee,
Jinsu Kim,
Çağlar Kutlu,
Andrew K. Yi,
Yasunobu Nakamura,
Seonjeong Oh,
Danho Ahn,
SungJae Bae,
Hyoungsoon Choi,
Jihoon Choi,
Yonuk Chong,
Woohyun Chung,
Violeta Gkika,
Jihn E. Kim,
Younggeun Kim,
Byeong Rok Ko,
Lino Miceli
, et al. (11 additional authors not shown)
Abstract:
We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practi…
▽ More
We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.
△ Less
Submitted 20 February, 2024;
originally announced February 2024.
-
Systematic Approach for Tuning Flux-driven Josephson Parametric Amplifiers for Stochastic Small Signals
Authors:
Çağlar Kutlu,
Saebyeok Ahn,
Sergey V. Uchaikin,
Soohyung Lee,
Arjan F. van Loo,
Yasunobu Nakamura,
Seonjeong Oh,
Yannis K. Semertzidis
Abstract:
Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage. While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the bes…
▽ More
Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage. While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance. In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties. In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning. Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps. The proposed methodology was successfully used in the context of a haloscope axion experiment.
△ Less
Submitted 9 May, 2023;
originally announced May 2023.
-
Four-channel System for Characterization of Josephson Parametric Amplifiers
Authors:
Boris I. Ivanov,
Jinmyeong Kim,
Çağlar Kutlu,
Arjan F. van Loo,
Yasunobu Nakamura,
Sergey V. Uchaikin,
Seonjeong Oh,
Violeta Gkika,
Andrei Matlashov,
Woohyun Chung,
Yannis K. Semertzidis
Abstract:
The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz. In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed supe…
▽ More
The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz. In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets. The measurements require continuous operation for months without interruptions for microwave component replacements. This is achieved by using different cryogenic engineering approaches including microwave RF-switching. The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology. It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA. In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements. The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements. The setup is placed at 20 mK inside the dry dilution refrigerator. The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables. We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down
△ Less
Submitted 9 May, 2023; v1 submitted 26 April, 2023;
originally announced April 2023.
-
CAPP Axion Search Experiments with Quantum Noise Limited Amplifiers
Authors:
Sergey V. Uchaikin,
Boris I. Ivanov,
Jinmyeong Kim,
Çağlar Kutlu,
Arjan F. Van Loo,
Yasunobu Nakamura,
Seonjeong OH,
Violeta Gkika,
Andrei Matlashov,
Woohyun Chung,
Yannis K. Semertzidis
Abstract:
The axion is expected to solve the strong CP problem of quantum chromodynamics and is one of the leading candidates for dark matter. CAPP in South Korea has several axion search experiments based on cavity haloscopes in the frequency range of 1-6 GHz. The main effort focuses on operation of the experiments with the highest possible sensitivity. It requires maintenance of the haloscopes at the lowe…
▽ More
The axion is expected to solve the strong CP problem of quantum chromodynamics and is one of the leading candidates for dark matter. CAPP in South Korea has several axion search experiments based on cavity haloscopes in the frequency range of 1-6 GHz. The main effort focuses on operation of the experiments with the highest possible sensitivity. It requires maintenance of the haloscopes at the lowest physical temperature in the range of mK and usage of low noise components to amplify the weak axion signal. We report development and operation of low noise amplifiers for 5 haloscope experiments targeting at different frequency ranges. The amplifiers show noise temperatures approaching the quantum limit.
△ Less
Submitted 24 April, 2023; v1 submitted 13 April, 2023;
originally announced April 2023.
-
Josephson Parametric Amplifier in Axion Experiments
Authors:
Jinmyeong Kim,
Boris I. Ivanov,
Çağlar Kutlu,
Seongtae Park,
Arjan F. Van Loo,
Yasunobu Nakamura,
Sergey V. Uchaikin,
Seonjeong Oh,
Violeta Gkika,
Andrei Matlashov,
Woohyun Chung,
Yannis K. Semertzidis
Abstract:
The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem. Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature. We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta. In our me…
▽ More
The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem. Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature. We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta. In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.
△ Less
Submitted 19 April, 2023; v1 submitted 10 April, 2023;
originally announced April 2023.
-
Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV
Authors:
Andrew K. Yi,
Saebyeok Ahn,
Çağlar Kutlu,
JinMyeong Kim,
Byeong Rok Ko,
Boris I. Ivanov,
HeeSu Byun,
Arjan F. van Loo,
SeongTae Park,
Junu Jeong,
Ohjoon Kwon,
Yasunobu Nakamura,
Sergey V. Uchaikin,
Jihoon Choi,
Soohyung Lee,
MyeongJae Lee,
Yun Chang Shin,
Jinsu Kim,
Doyu Lee,
Danho Ahn,
SungJae Bae,
Jiwon Lee,
Younggeun Kim,
Violeta Gkika,
Ki Woong Lee
, et al. (7 additional authors not shown)
Abstract:
We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from…
▽ More
We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.
△ Less
Submitted 13 July, 2023; v1 submitted 2 February, 2023;
originally announced February 2023.
-
Search for Dark Matter Axions with CAST-CAPP
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a st…
▽ More
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity
Authors:
Andrew K. Yi,
Saebyeok Ahn,
Çağlar Kutlu,
JinMyeong Kim,
Byeong Rok Ko,
Boris I. Ivanov,
HeeSu Byun,
Arjan F. van Loo,
SeongTae Park,
Junu Jeong,
Ohjoon Kwon,
Yasunobu Nakamura,
Sergey V. Uchaikin,
Jihoon Choi,
Soohyung Lee,
MyeongJae Lee,
Yun Chang Shin,
Jinsu Kim,
Doyu Lee,
Danho Ahn,
SungJae Bae,
Jiwon Lee,
Younggeun Kim,
Violeta Gkika,
Ki Woong Lee
, et al. (7 additional authors not shown)
Abstract:
We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density.
The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level.
The achieved experimental…
▽ More
We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density.
The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level.
The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density.
The CAPP-12TB haloscope will continue the search over a wide range of axion masses.
△ Less
Submitted 16 February, 2023; v1 submitted 19 October, 2022;
originally announced October 2022.
-
Near-Quantum-Noise Axion Dark Matter Search at CAPP around 9.5 $μ$eV
Authors:
Jinsu Kim,
Ohjoon Kwon,
Çağlar Kutlu,
Woohyun Chung,
Andrei Matlashov,
Sergey Uchaikin,
Arjan Ferdinand van Loo,
Yasunobu Nakamura,
Seonjeong Oh,
HeeSu Byun,
Danho Ahn,
Yannis K. Semertzidis
Abstract:
We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 $μ$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-s…
▽ More
We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 $μ$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivity than existing limits.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
Detector Array Readout with Traveling Wave Amplifiers
Authors:
A. Giachero,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chang,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
G. Maccarrone,
B. Margesin,
G. Maruccio,
A. Matlashov
, et al. (13 additional authors not shown)
Abstract:
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter dete…
▽ More
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project has the goal of developing high-performing innovative traveling wave parametric amplifiers (TWPAs) with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Bimodal Approach for Noise Figures of Merit Evaluation in Quantum-Limited Josephson Traveling Wave Parametric Amplifiers
Authors:
L. Fasolo,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chung,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
P. Livreri,
G. Maccarrone,
B. Margesin,
G. Maruccio
, et al. (15 additional authors not shown)
Abstract:
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplificatio…
▽ More
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplification and noise generation for key case study input states (Fock and coherents). Furthermore, we present an analysis of the output signals generated by the parametric amplification mechanism when thermal noise fluctuations feed the device.
△ Less
Submitted 29 December, 2021; v1 submitted 30 September, 2021;
originally announced September 2021.
-
Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments
Authors:
Çağlar Kutlu,
Arjan F. van Loo,
Sergey V. Uchaikin,
Andrei N. Matlashov,
Doyu Lee,
Seonjeong Oh,
Jinsu Kim,
Woohyun Chung,
Yasunobu Nakamura,
Yannis K. Semertzidis
Abstract:
The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem of QCD and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors…
▽ More
The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem of QCD and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
First Results from Axion Haloscope at CAPP around 10.7 $μ$eV
Authors:
Ohjoon Kwon,
Doyu Lee,
Woohyun Chung,
Danho Ahn,
HeeSu Byun,
Fritz Caspers,
Hyoungsoon Choi,
Jihoon Choi,
Yonuk Chung,
Hoyong Jeong,
Junu Jeong,
Jihn E Kim,
Jinsu Kim,
Çağlar Kutlu,
Jihnhwan Lee,
MyeongJae Lee,
Soohyung Lee,
Andrei Matlashov,
Seonjeong Oh,
Seongtae Park,
Sergey Uchaikin,
SungWoo Youn,
Yannis K. Semertzidis
Abstract:
The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confide…
▽ More
The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.
△ Less
Submitted 28 April, 2021; v1 submitted 19 December, 2020;
originally announced December 2020.
-
Axion Dark Matter Research with IBS/CAPP
Authors:
Yannis K. Semertzidis,
Jihn E. Kim,
SungWoo Youn,
Jihoon Choi,
Woohyun Chung,
Selcuk Haciomeroglu,
Dongmin Kim,
Jingeun Kim,
ByeongRok Ko,
Ohjoon Kwon,
Andrei Matlashov,
Lino Miceli,
Hiroaki Natori,
Seongtae Park,
MyeongJae Lee,
Soohyung Lee,
Elena Sala,
Yunchang Shin,
Taehyeon Seong,
Sergey Uchaykin,
Danho Ahn,
Saebyeok Ahn,
Seung Pyo Chang,
Wheeyeon Cheong,
Hoyong Jeong
, et al. (12 additional authors not shown)
Abstract:
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on th…
▽ More
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.
△ Less
Submitted 25 October, 2019;
originally announced October 2019.