Zum Hauptinhalt springen

Showing 1–31 of 31 results for author: Orsini, M

.
  1. arXiv:2211.03521  [pdf, other

    cs.AI

    On the importance of data collection for training general goal-reaching policies

    Authors: Alexis Jacq, Manu Orsini, Gabriel Dulac-Arnold, Olivier Pietquin, Matthieu Geist, Olivier Bachem

    Abstract: Recent advances in ML suggest that the quantity of data available to a model is one of the primary bottlenecks to high performance. Although for language-based tasks there exist almost unlimited amounts of reasonably coherent data to train from, this is generally not the case for Reinforcement Learning, especially when dealing with a novel environment. In effect, even a relatively trivial continuo… ▽ More

    Submitted 20 February, 2023; v1 submitted 7 November, 2022; originally announced November 2022.

  2. arXiv:2106.00672  [pdf, other

    cs.LG cs.AI cs.NE

    What Matters for Adversarial Imitation Learning?

    Authors: Manu Orsini, Anton Raichuk, Léonard Hussenot, Damien Vincent, Robert Dadashi, Sertan Girgin, Matthieu Geist, Olivier Bachem, Olivier Pietquin, Marcin Andrychowicz

    Abstract: Adversarial imitation learning has become a popular framework for imitation in continuous control. Over the years, several variations of its components were proposed to enhance the performance of the learned policies as well as the sample complexity of the algorithm. In practice, these choices are rarely tested all together in rigorous empirical studies. It is therefore difficult to discuss and un… ▽ More

    Submitted 1 June, 2021; originally announced June 2021.

  3. arXiv:2105.12034  [pdf, other

    cs.LG

    Hyperparameter Selection for Imitation Learning

    Authors: Leonard Hussenot, Marcin Andrychowicz, Damien Vincent, Robert Dadashi, Anton Raichuk, Lukasz Stafiniak, Sertan Girgin, Raphael Marinier, Nikola Momchev, Sabela Ramos, Manu Orsini, Olivier Bachem, Matthieu Geist, Olivier Pietquin

    Abstract: We address the issue of tuning hyperparameters (HPs) for imitation learning algorithms in the context of continuous-control, when the underlying reward function of the demonstrating expert cannot be observed at any time. The vast literature in imitation learning mostly considers this reward function to be available for HP selection, but this is not a realistic setting. Indeed, would this reward fu… ▽ More

    Submitted 25 May, 2021; originally announced May 2021.

    Comments: ICML 2021

  4. arXiv:2006.05990  [pdf, other

    cs.LG stat.ML

    What Matters In On-Policy Reinforcement Learning? A Large-Scale Empirical Study

    Authors: Marcin Andrychowicz, Anton Raichuk, Piotr Stańczyk, Manu Orsini, Sertan Girgin, Raphael Marinier, Léonard Hussenot, Matthieu Geist, Olivier Pietquin, Marcin Michalski, Sylvain Gelly, Olivier Bachem

    Abstract: In recent years, on-policy reinforcement learning (RL) has been successfully applied to many different continuous control tasks. While RL algorithms are often conceptually simple, their state-of-the-art implementations take numerous low- and high-level design decisions that strongly affect the performance of the resulting agents. Those choices are usually not extensively discussed in the literatur… ▽ More

    Submitted 10 June, 2020; originally announced June 2020.

  5. arXiv:2006.00979  [pdf, other

    cs.LG cs.AI

    Acme: A Research Framework for Distributed Reinforcement Learning

    Authors: Matthew W. Hoffman, Bobak Shahriari, John Aslanides, Gabriel Barth-Maron, Nikola Momchev, Danila Sinopalnikov, Piotr Stańczyk, Sabela Ramos, Anton Raichuk, Damien Vincent, Léonard Hussenot, Robert Dadashi, Gabriel Dulac-Arnold, Manu Orsini, Alexis Jacq, Johan Ferret, Nino Vieillard, Seyed Kamyar Seyed Ghasemipour, Sertan Girgin, Olivier Pietquin, Feryal Behbahani, Tamara Norman, Abbas Abdolmaleki, Albin Cassirer, Fan Yang , et al. (14 additional authors not shown)

    Abstract: Deep reinforcement learning (RL) has led to many recent and groundbreaking advances. However, these advances have often come at the cost of both increased scale in the underlying architectures being trained as well as increased complexity of the RL algorithms used to train them. These increases have in turn made it more difficult for researchers to rapidly prototype new ideas or reproduce publishe… ▽ More

    Submitted 20 September, 2022; v1 submitted 1 June, 2020; originally announced June 2020.

    Comments: This work presents a second version of the paper which coincides with an increase in modularity, additional emphasis on offline, imitation and learning from demonstrations algorithms, as well as various new agents implemented as part of Acme

  6. arXiv:2004.02024  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Authors: The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, V. Barbaryan, A. Barrado Olmedo, G. Batignani , et al. (290 additional authors not shown)

    Abstract: Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the… ▽ More

    Submitted 26 February, 2021; v1 submitted 4 April, 2020; originally announced April 2020.

    Comments: 26 pages, 22 figures, 3 tables

    Journal ref: Eur. Phys. J. C (2021) 81: 153

  7. arXiv:2002.07794  [pdf, other

    hep-ex hep-ph physics.ins-det

    Effective field theory interactions for liquid argon target in DarkSide-50 experiment

    Authors: The DarkSide-50 Collaboration, :, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, M. Ave, H. O. Back, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. M. Bonivento, B. Bottino, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini, M. Carpinelli , et al. (143 additional authors not shown)

    Abstract: We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper… ▽ More

    Submitted 18 February, 2020; originally announced February 2020.

    Comments: Accepted by PRD

  8. arXiv:2001.08106  [pdf, other

    astro-ph.IM physics.ins-det

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Authors: The DarkSide Collaboration, C. E. Aalseth, S. Abdelhakim, F. Acerbi, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, A. Barrado Olmedo, G. Batignani , et al. (306 additional authors not shown)

    Abstract: Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa… ▽ More

    Submitted 22 January, 2020; originally announced January 2020.

    Comments: 13 pages, 8 figures. Corresponding author: E. Sánchez García

  9. arXiv:1907.09332  [pdf, other

    astro-ph.IM physics.ins-det

    Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, M. Ave, H. O. Back, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. M. Bonivento, B. Bottino, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini, M. Carpinelli, S. Catalanotti, V. Cataudella , et al. (141 additional authors not shown)

    Abstract: We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)… ▽ More

    Submitted 28 October, 2019; v1 submitted 22 July, 2019; originally announced July 2019.

    Journal ref: JINST 14 P11018 (2019)

  10. arXiv:1802.07198  [pdf, other

    astro-ph.CO astro-ph.IM

    DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (150 additional authors not shown)

    Abstract: The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark ma… ▽ More

    Submitted 19 November, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: 17 pages, 13 figures. V3 changes: updates for clarity for publication, additional figure

    Journal ref: Phys. Rev. D 98, 102006 (2018)

  11. Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, D. M. Asner, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati , et al. (171 additional authors not shown)

    Abstract: We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.

    Submitted 3 October, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: replaced with published version

    Journal ref: Phys. Rev. Lett. 121, 111303 (2018)

  12. arXiv:1802.06994  [pdf, other

    astro-ph.HE astro-ph.CO

    Low-Mass Dark Matter Search with the DarkSide-50 Experiment

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, D. M. Asner, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati , et al. (170 additional authors not shown)

    Abstract: We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detecto… ▽ More

    Submitted 28 August, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: 9 pages, 8 figures; submission accepted by journal

    Journal ref: Phys. Rev. Lett. 121, 081307 (2018)

  13. Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, M. P. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (141 additional authors not shown)

    Abstract: We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs… ▽ More

    Submitted 23 July, 2018; v1 submitted 5 February, 2018; originally announced February 2018.

  14. arXiv:1707.09889  [pdf, other

    physics.ins-det hep-ex

    The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter

    Authors: DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, D. M. Asner, M. Ave, H. O. Back, B. Baldin, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela , et al. (155 additional authors not shown)

    Abstract: The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which proce… ▽ More

    Submitted 20 November, 2017; v1 submitted 31 July, 2017; originally announced July 2017.

    Comments: 24 pages

  15. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  16. arXiv:1707.05630  [pdf, other

    physics.ins-det hep-ex

    Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini, S. Catalanotti, V. Cataudella , et al. (125 additional authors not shown)

    Abstract: A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni… ▽ More

    Submitted 26 September, 2017; v1 submitted 18 July, 2017; originally announced July 2017.

    Comments: 29 pages, 23 figures, 1 table

  17. Cryogenic Characterization of FBK RGB-HD SiPMs

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Ampudia, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, H. O. Back, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, R. Bunker , et al. (246 additional authors not shown)

    Abstract: We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio… ▽ More

    Submitted 12 September, 2017; v1 submitted 19 May, 2017; originally announced May 2017.

  18. CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, B. Baldin, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (140 additional authors not shown)

    Abstract: This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liqui… ▽ More

    Submitted 27 September, 2017; v1 submitted 8 November, 2016; originally announced November 2016.

    Comments: 21 pages, 11 figures

  19. arXiv:1611.00241  [pdf, other

    physics.ins-det nucl-ex

    Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, B. Baldin, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini , et al. (136 additional authors not shown)

    Abstract: Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

    Submitted 4 November, 2016; v1 submitted 1 November, 2016; originally announced November 2016.

    Comments: 5 pages, 5 figures

    Journal ref: P. Agnes et al 2017 JINST 12 P01021

  20. arXiv:1606.03316  [pdf, other

    physics.ins-det hep-ex

    The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors

    Authors: P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello, M. Carlini, S. Catalanotti , et al. (133 additional authors not shown)

    Abstract: DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detec… ▽ More

    Submitted 10 June, 2016; originally announced June 2016.

    Journal ref: Journal of Instrumentation, 11 (2016): P12007

  21. arXiv:1512.07896  [pdf, other

    physics.ins-det hep-ex

    The veto system of the DarkSide-50 experiment

    Authors: The DarkSide Collaboration, P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello , et al. (136 additional authors not shown)

    Abstract: Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector… ▽ More

    Submitted 24 December, 2015; originally announced December 2015.

    Journal ref: Journal of Instrumentation, 11 (2016): P03016

  22. arXiv:1510.00702  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Results from the first use of low radioactivity argon in a dark matter search

    Authors: The DarkSide Collaboration, P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello , et al. (136 additional authors not shown)

    Abstract: Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La… ▽ More

    Submitted 13 April, 2016; v1 submitted 2 October, 2015; originally announced October 2015.

    Comments: Accepted by Phys. Rev. D

    Journal ref: Phys. Rev. D 93, 081101 (2016)

  23. arXiv:1412.2969  [pdf, ps, other

    astro-ph.IM physics.ins-det

    The Electronics and Data Acquisition System of the DarkSide Dark Matter Search

    Authors: The DarkSide Collaboration, P. Agnes, T. Alexander, A. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, A. Brigatti, J. Brodsky, F. Budano, L. Cadonati, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello, P. Cavalcante, A. Chavarria, A. Chepurnov, A. G. Cocco, L. Crippa, D. D'Angelo , et al. (121 additional authors not shown)

    Abstract: It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del… ▽ More

    Submitted 22 January, 2015; v1 submitted 9 December, 2014; originally announced December 2014.

  24. arXiv:1410.0653  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso

    Authors: P. Agnes, T. Alexander, A. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, A. Brigatti, J. Brodsky, F. Budano, L. Cadonati, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello, P. Cavalcante, A. Chavarria, A. Chepurnov, A. G. Cocco, L. Crippa, D. D'Angelo, M. D'Incecco , et al. (121 additional authors not shown)

    Abstract: We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci… ▽ More

    Submitted 27 February, 2015; v1 submitted 2 October, 2014; originally announced October 2014.

    Comments: 26 pages, 7 figures; updated figures and references, notably Fig. 7 has updated CDMSII curve; fixed typos; clarified some language and figures; updated references

    Journal ref: Physics Letters B 743, 456 (2015)

  25. arXiv:1207.0591  [pdf, other

    physics.ins-det hep-ex

    GPS-based CERN-LNGS time link for Borexino

    Authors: B. Caccianiga, P. Cavalcante, G. Cerretto, H. Esteban, G. Korga, M. Misiaszek, M. Orsini, M. Pallavicini, V. Pettiti, C. Plantard, A. Razeto

    Abstract: We describe the design, the equipment, and the calibration of a new GPS based time link between CERN and the Borexino experiment at the Gran Sasso Laboratory in Italy. This system has been installed and operated in Borexino since March 2012, and used for a precise measurement of CNGS muon neutrinos speed in May 2012. The result of the measurement will be reported in a different letter.

    Submitted 31 July, 2012; v1 submitted 3 July, 2012; originally announced July 2012.

    Comments: 13 pages, 11 figures

  26. Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches

    Authors: T. Alexander, D. Alton, K. Arisaka, H. O. Back, P. Beltrame, J. Benziger, G. Bonfini, A. Brigatti, J. Brodsky, L. Cadonati, F. Calaprice, A. Candela, H. Cao, P. Cavalcante, A. Chavarria, A. Chepurnov, D. Cline, A. G. Cocco, C. Condon, D. D'Angelo, S. Davini, E. De Haas, A. Derbin, G. Di Pietro, I. Dratchnev , et al. (97 additional authors not shown)

    Abstract: As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-r… ▽ More

    Submitted 14 August, 2013; v1 submitted 27 April, 2012; originally announced April 2012.

    Comments: 10 pages, 7 figures, Accepted for publication in Astroparticle Physics

  27. Limits Due to Instrumental Polarisation in CMB Experiments at Microwave Wavelengths

    Authors: E. Carretti, R. Tascone, S. Cortiglioni, J. Monari, M. Orsini

    Abstract: An extended analysis of some instrumental polarisation sources has been done, as a consequence of the renewed interest in extremely sensitive polarisation measurements stimulated by Cosmic Microwave Background experiments. The case of correlation polarimeters, being them more suitable than other configurations, has been studied in detail and the algorithm has been derived to calculate their intr… ▽ More

    Submitted 20 March, 2001; originally announced March 2001.

    Comments: 20 pages, 5 postscript figures. Accepted for publication in New Astronomy (see http://www.elsevier.nl/locate/newast)

    Journal ref: NewA 6 (2001) 173-188

  28. The angular power spectra of polarized Galactic synchrotron

    Authors: M. Tucci, E. Carretti, S. Cecchini, R. Fabbri, M. Orsini, E. Pierpaoli

    Abstract: We derive the angular power spectra of intensity and polarization of Galactic synchrotron emission in the range 36 < l < 10^3 from the Parkes survey mapping the southern Galactic plane at 2.4 GHz. The polarization spectra of both electric and magnetic parity up to l \simeq 10^3 are approximated very well by power laws with slope coefficients \simeq 1.4, quite different from the CMB spectra. We s… ▽ More

    Submitted 27 June, 2000; originally announced June 2000.

    Comments: 15 pages with 6 eps figures. Accepted for publication in New Astronomy

    Journal ref: New Astronomy (2000), v. 5, p. 181-190

  29. An Overview of the SPOrt Experiment

    Authors: Michele Orsini, Ettore Carretti, Stefano Cortiglioni

    Abstract: The Sky Polarization Observatory is an experiment selected by ESA for the Early Opportunity Phase onboard the International Space Station. SPOrt is the first payload specifically designed for polarization measurements, it will provide near full sky maps of the sky polarized emission at four microwave frequencies between 22 and 90 GHz. Current design of SPOrt will be presented, together with an o… ▽ More

    Submitted 22 May, 2000; originally announced May 2000.

    Comments: 9 pages, 4 Postscript figures; to be published in Gamov Memorial International Conference Proceedings, Astronomy and Astrophysical Transactions, v.20, 2000; SPOrt Project Home Page: http://sport.tesre.bo.cnr.it/

  30. The SPOrt Project: Cosmological and Astrophysical Goals

    Authors: R. Fabbri, S. Cortiglioni, S. Cecchini, M. Orsini, E. Carretti, G. Boella, G. Sironi, J. Monari, A. Orfei, R. Tascone, U. Pisani, K. W. Ng, L. Nicastro, L. Popa, I. A. Strukov, M. V. Sazhin

    Abstract: We present the cosmological and astrophysical objectives of the SPOrt mission, which is scheduled for flying on the International Space Station (ISS) in the year 2002 with the purpose of measuring the diffuse sky polarized radiation in the microwave region. We discuss the problem of disentangling the cosmic background polarized signal from the Galactic foregrounds.

    Submitted 26 January, 1999; originally announced January 1999.

    Comments: 10 pages; 5 PS figures; requires aipproc2.cls, aipproc2.sty, epsfc.tex; to appear in Proc. of ``3K Cosmology'', Rome 5-10 Oct. 1998

    Journal ref: AIPConf.Proc.476:194-203,1999

  31. The SPOrt Project: an Experimental Overview

    Authors: S. Cortiglioni, S. Cecchini, E. Carretti, M. Orsini, R. Fabbri, G. Boella, G. Sironi, J. Monari, A. Orfei, R. Tascone, U. Pisani, K. W. Ng, L. Nicastro, L. Popa, I. A. Strukov, M. V. Sazhin

    Abstract: The Sky Polarization Observatory (SPOrt) is presented as a project aimed to measure the diffuse sky polarized emission, from the International Space Station, in the frequency range 20-90 GHz with 7 degrees of HPBW. The SPOrt experimental configuration is described with emphasis on the aspects that make SPOrt the first European scientific payload operating at microwave wavelengths.

    Submitted 26 January, 1999; originally announced January 1999.

    Comments: 8 pages; 5 PS figures; requires aipproc2.cls, aipproc2.sty, epsfc.sty; to appear in Proc. of ``3K Cosmology'', Rome 5-10 Oct. 1998