-
Towards Transcranial 3D Ultrasound Localization Microscopy of the Nonhuman Primate Brain
Authors:
Paul Xing,
Vincent Perrot,
Adan Ulises Dominguez-Vargas,
Stephan Quessy,
Numa Dancause,
Jean Provost
Abstract:
Hemodynamic changes occur in stroke and neurodegenerative diseases. Developing imaging techniques allowing the in vivo visualization and quantification of cerebral blood flow would help better understand the underlying mechanism of those cerebrovascular diseases. 3D ultrasound localization microscopy (ULM) is a novel technology that can map the microvasculature of the brain at large depth and has…
▽ More
Hemodynamic changes occur in stroke and neurodegenerative diseases. Developing imaging techniques allowing the in vivo visualization and quantification of cerebral blood flow would help better understand the underlying mechanism of those cerebrovascular diseases. 3D ultrasound localization microscopy (ULM) is a novel technology that can map the microvasculature of the brain at large depth and has been mainly used until now in rodents. Here, we demonstrated the feasibility of 3D ULM of the nonhuman primate (NHP) brain with a single 256-channels programmable ultrasound scanner. We achieved a highly resolved vascular map of the macaque brain at large depth in presence of craniotomy and durectomy using an 8-MHz multiplexed matrix probe. We were able to distinguish vessels as small as 26.9 μm. We also demonstrated that transcranial imaging of the macaque brain at similar depth was feasible using a 3-MHz probe and achieved a resolution of 60.4 μm. This work paves the way to clinical application of 3D ULM.
△ Less
Submitted 4 April, 2024;
originally announced April 2024.
-
Equivalent Time Active Cavitation Imaging
Authors:
Simon Blais,
Jonathan Poree,
Gerardo Ramos-Palacios,
Samuel Desmarais,
Vincent Perrot,
Abbas Sadikot,
Jean Provost
Abstract:
The development of neurologically active drugs faces a challenge in treating brain diseases due to the blood-brain barrier's impermeability. High-intensity focused ultrasound can open the barrier in a targeted manner, expanding treatment options. However, this procedure risks brain damage and off-target effects without proper monitoring. Current monitoring methods have limitations. We present Equi…
▽ More
The development of neurologically active drugs faces a challenge in treating brain diseases due to the blood-brain barrier's impermeability. High-intensity focused ultrasound can open the barrier in a targeted manner, expanding treatment options. However, this procedure risks brain damage and off-target effects without proper monitoring. Current monitoring methods have limitations. We present Equivalent Time Active Cavitation Imaging, a novel ultrasound modality that characterizes the ultrasound pressure field during treatment. This system utilizes a unique plane wave sequence and an algorithm to filter the microbubble signal for pressure field mapping. We conducted pressure measurements in vitro for comparison with hydrophones and in vivo during blood-brain barrier opening in mice. Our modality successfully spatiotemporally characterizes the pressure field with an active imaging setup, demonstrating good correlation with hydrophone measurements. Experimental in vivo results are promising, establishing the feasibility of this monitoring method. In conclusion, this proof of concept represents a significant step toward a new ultrasound modality for monitoring blood-brain barrier opening using focused ultrasound. This approach offers a safer and more precise monitoring method, opening new possibilities for treating brain diseases.
△ Less
Submitted 19 October, 2023;
originally announced October 2023.
-
Ergodic encoding for single-element ultrasound imaging in vivo
Authors:
Olivier Caron-Grenier,
Jonathan Poree,
Vincent Perrot,
Gerardo Ramos-Palacio,
Abbas F Sadikot,
Jean Provost
Abstract:
Conventional ultrasound imaging relies on the computation of geometric time delay from multiple sensors to detect the position of a scatterer. In this paper, we present Ergodic Relay Ultrasound Imaging (ERUI), a method that utilizes an ergodic cavity down to a single ultrasonic sensor for ultrasound imaging. With the proposed method, the ergodic cavity creates a unique temporal signature that enco…
▽ More
Conventional ultrasound imaging relies on the computation of geometric time delay from multiple sensors to detect the position of a scatterer. In this paper, we present Ergodic Relay Ultrasound Imaging (ERUI), a method that utilizes an ergodic cavity down to a single ultrasonic sensor for ultrasound imaging. With the proposed method, the ergodic cavity creates a unique temporal signature that encodes the position of a scatterer. When compared to standard approaches, ERUI enables the generation of images of comparable quality while utilizing fewer detector elements. Our results suggest that ERUI has the potential to achieve image resolution similar to that of traditional imaging techniques, shifting the complexity from hardware to sofware. The demonstrated feasibility offers a promising path towards ultrasound probes with reduced costs and complexity for more portable scanning devices.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Quantitative pulsatility measurements using 3D Dynamic Ultrasound Localization Microscopy
Authors:
Chloé Bourquin,
Jonathan Porée,
Brice Rauby,
Vincent Perrot,
Nin Ghigo,
Hatim Belgharbi,
Samuel Bélanger,
Gerardo Ramos-Palacios,
Nelson Cortés,
Hugo Ladret,
Lamyae Ikan,
Christian Casanova,
Frédéric Lesage,
Jean Provost
Abstract:
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM…
▽ More
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.
△ Less
Submitted 24 March, 2023;
originally announced March 2023.
-
Phase Aberration Correction for in vivo Ultrasound Localization Microscopy Using a Spatiotemporal Complex-Valued Neural Network
Authors:
Paul Xing,
Jonathan Porée,
Brice Rauby,
Antoine Malescot,
Éric Martineau,
Vincent Perrot,
Ravi L. Rungta,
Jean Provost
Abstract:
Ultrasound Localization Microscopy (ULM) can map microvessels at a resolution of a few micrometers (μm). Transcranial ULM remains challenging in presence of aberrations caused by the skull, which lead to localization errors. Herein, we propose a deep learning approach based on complex-valued convolutional neural networks (CV-CNNs) to retrieve the aberration function, which can then be used to form…
▽ More
Ultrasound Localization Microscopy (ULM) can map microvessels at a resolution of a few micrometers (μm). Transcranial ULM remains challenging in presence of aberrations caused by the skull, which lead to localization errors. Herein, we propose a deep learning approach based on complex-valued convolutional neural networks (CV-CNNs) to retrieve the aberration function, which can then be used to form enhanced images using standard delay-and-sum beamforming. CV-CNNs were selected as they can apply time delays through multiplication with in-phase quadrature input data. Predicting the aberration function rather than corrected images also confers enhanced explainability to the network. In addition, 3D spatiotemporal convolutions were used for the network to leverage entire microbubble tracks. For training and validation, we used an anatomically and hemodynamically realistic mouse brain microvascular network model to simulate the flow of microbubbles in presence of aberration. The proposed CV-CNN performance was compared to the coherence-based method by using microbubble tracks. We then confirmed the capability of the proposed network to generalize to transcranial \textit{in vivo} data in the mouse brain (n=3). Vascular reconstructions using a locally predicted aberration function included additional and sharper vessels. The CV-CNN was more robust than the coherence-based method and could perform aberration correction in a 6-month-old mouse. After correction, we measured a resolution of 15.6 μm for younger mice, representing an improvement of 25.8 $\%$, while the resolution was improved by 13.9 $\%$ for the 6-month-old mouse. This work leads to different applications for complex-valued convolutions in biomedical imaging and strategies to perform transcranial ULM.
△ Less
Submitted 17 July, 2023; v1 submitted 21 September, 2022;
originally announced September 2022.
-
So you think you can DAS? A viewpoint on delay-and-sum beamforming
Authors:
Vincent Perrot,
Maxime Polichetti,
François Varray,
Damien Garcia
Abstract:
Delay-and-sum (DAS) is the most widespread digital beamformer in high-frame-rate ultrasound imaging. Its implementation is simple and compatible with real-time applications. In this viewpoint article, we describe the fundamentals of DAS beamforming. The underlying theory and numerical approach are detailed so that users can be aware of its functioning and limitations. In particular, we discuss the…
▽ More
Delay-and-sum (DAS) is the most widespread digital beamformer in high-frame-rate ultrasound imaging. Its implementation is simple and compatible with real-time applications. In this viewpoint article, we describe the fundamentals of DAS beamforming. The underlying theory and numerical approach are detailed so that users can be aware of its functioning and limitations. In particular, we discuss the importance of the f-number and speed of sound on image quality, and propose one solution to set their values from a physical viewpoint. We suggest determining the f-number from the directivity of the transducer elements and the speed of sound from the phase dispersion of the delayed signals. Simplified Matlab codes are provided for the sake of clarity and openness. The effect of the f-number and speed of sound on the lateral resolution and contrast-to-noise ratio was investigated in vitro and in vivo. If not properly preset, these two factors had a substantial negative impact on standard metrics of image quality (namely CNR and FWHM). When beamforming with DAS in vitro or in vivo, it is recommended to optimize these parameters in order to use it wisely and prevent image degradation.
△ Less
Submitted 2 February, 2021; v1 submitted 23 July, 2020;
originally announced July 2020.