Automated Quality Controlled Analysis of 2D Phase Contrast Cardiovascular Magnetic Resonance Imaging
Authors:
Emily Chan,
Ciaran O'Hanlon,
Carlota Asegurado Marquez,
Marwenie Petalcorin,
Jorge Mariscal-Harana,
Haotian Gu,
Raymond J. Kim,
Robert M. Judd,
Phil Chowienczyk,
Julia A. Schnabel,
Reza Razavi,
Andrew P. King,
Bram Ruijsink,
Esther Puyol-Antón
Abstract:
Flow analysis carried out using phase contrast cardiac magnetic resonance imaging (PC-CMR) enables the quantification of important parameters that are used in the assessment of cardiovascular function. An essential part of this analysis is the identification of the correct CMR views and quality control (QC) to detect artefacts that could affect the flow quantification. We propose a novel deep lear…
▽ More
Flow analysis carried out using phase contrast cardiac magnetic resonance imaging (PC-CMR) enables the quantification of important parameters that are used in the assessment of cardiovascular function. An essential part of this analysis is the identification of the correct CMR views and quality control (QC) to detect artefacts that could affect the flow quantification. We propose a novel deep learning based framework for the fully-automated analysis of flow from full CMR scans that first carries out these view selection and QC steps using two sequential convolutional neural networks, followed by automatic aorta and pulmonary artery segmentation to enable the quantification of key flow parameters. Accuracy values of 0.958 and 0.914 were obtained for view classification and QC, respectively. For segmentation, Dice scores were $>$0.969 and the Bland-Altman plots indicated excellent agreement between manual and automatic peak flow values. In addition, we tested our pipeline on an external validation data set, with results indicating good robustness of the pipeline. This work was carried out using multivendor clinical data consisting of 986 cases, indicating the potential for the use of this pipeline in a clinical setting.
△ Less
Submitted 28 September, 2022;
originally announced September 2022.
An AI tool for automated analysis of large-scale unstructured clinical cine CMR databases
Authors:
Jorge Mariscal-Harana,
Clint Asher,
Vittoria Vergani,
Maleeha Rizvi,
Louise Keehn,
Raymond J. Kim,
Robert M. Judd,
Steffen E. Petersen,
Reza Razavi,
Andrew King,
Bram Ruijsink,
Esther Puyol-Antón
Abstract:
Artificial intelligence (AI) techniques have been proposed for automating analysis of short axis (SAX) cine cardiac magnetic resonance (CMR), but no CMR analysis tool exists to automatically analyse large (unstructured) clinical CMR datasets. We develop and validate a robust AI tool for start-to-end automatic quantification of cardiac function from SAX cine CMR in large clinical databases. Our pip…
▽ More
Artificial intelligence (AI) techniques have been proposed for automating analysis of short axis (SAX) cine cardiac magnetic resonance (CMR), but no CMR analysis tool exists to automatically analyse large (unstructured) clinical CMR datasets. We develop and validate a robust AI tool for start-to-end automatic quantification of cardiac function from SAX cine CMR in large clinical databases. Our pipeline for processing and analysing CMR databases includes automated steps to identify the correct data, robust image pre-processing, an AI algorithm for biventricular segmentation of SAX CMR and estimation of functional biomarkers, and automated post-analysis quality control to detect and correct errors. The segmentation algorithm was trained on 2793 CMR scans from two NHS hospitals and validated on additional cases from this dataset (n=414) and five external datasets (n=6888), including scans of patients with a range of diseases acquired at 12 different centres using CMR scanners from all major vendors. Median absolute errors in cardiac biomarkers were within the range of inter-observer variability: <8.4mL (left ventricle volume), <9.2mL (right ventricle volume), <13.3g (left ventricular mass), and <5.9% (ejection fraction) across all datasets. Stratification of cases according to phenotypes of cardiac disease and scanner vendors showed good performance across all groups. We show that our proposed tool, which combines image pre-processing steps, a domain-generalisable AI algorithm trained on a large-scale multi-domain CMR dataset and quality control steps, allows robust analysis of (clinical or research) databases from multiple centres, vendors, and cardiac diseases. This enables translation of our tool for use in fully-automated processing of large multi-centre databases.
△ Less
Submitted 5 July, 2023; v1 submitted 15 June, 2022;
originally announced June 2022.