Zum Hauptinhalt springen

Showing 1–7 of 7 results for author: Schmetterer, L

Searching in archive cs. Search in all archives.
.
  1. arXiv:2301.02837  [pdf

    cs.LG

    The 3D Structural Phenotype of the Glaucomatous Optic Nerve Head and its Relationship with The Severity of Visual Field Damage

    Authors: Fabian A. Braeu, Thanadet Chuangsuwanich, Tin A. Tun, Shamira A. Perera, Rahat Husain, Aiste Kadziauskiene, Leopold Schmetterer, Alexandre H. Thiéry, George Barbastathis, Tin Aung, Michaël J. A. Girard

    Abstract: $\bf{Purpose}$: To describe the 3D structural changes in both connective and neural tissues of the optic nerve head (ONH) that occur concurrently at different stages of glaucoma using traditional and AI-driven approaches. $\bf{Methods}$: We included 213 normal, 204 mild glaucoma (mean deviation [MD] $\ge… ▽ More

    Submitted 7 January, 2023; originally announced January 2023.

  2. arXiv:2210.06664  [pdf

    eess.IV cs.AI cs.CV

    Are Macula or Optic Nerve Head Structures better at Diagnosing Glaucoma? An Answer using AI and Wide-Field Optical Coherence Tomography

    Authors: Charis Y. N. Chiang, Fabian Braeu, Thanadet Chuangsuwanich, Royston K. Y. Tan, Jacqueline Chua, Leopold Schmetterer, Alexandre Thiery, Martin Buist, Michaël J. A. Girard

    Abstract: Purpose: (1) To develop a deep learning algorithm to automatically segment structures of the optic nerve head (ONH) and macula in 3D wide-field optical coherence tomography (OCT) scans; (2) To assess whether 3D macula or ONH structures (or the combination of both) provide the best diagnostic power for glaucoma. Methods: A cross-sectional comparative study was performed which included wide-field sw… ▽ More

    Submitted 12 October, 2022; originally announced October 2022.

    Comments: 23 pages, 5 figures

  3. arXiv:2010.11698  [pdf, other

    eess.IV cs.CV

    OCT-GAN: Single Step Shadow and Noise Removal from Optical Coherence Tomography Images of the Human Optic Nerve Head

    Authors: Haris Cheong, Sripad Krishna Devalla, Thanadet Chuangsuwanich, Tin A. Tun, Xiaofei Wang, Tin Aung, Leopold Schmetterer, Martin L. Buist, Craig Boote, Alexandre H. Thiéry, Michaël J. A. Girard

    Abstract: Speckle noise and retinal shadows within OCT B-scans occlude important edges, fine textures and deep tissues, preventing accurate and robust diagnosis by algorithms and clinicians. We developed a single process that successfully removed both noise and retinal shadows from unseen single-frame B-scans within 10.4ms. Mean average gradient magnitude (AGM) for the proposed algorithm was 57.2% higher th… ▽ More

    Submitted 6 October, 2020; originally announced October 2020.

    Comments: 20 pages, 7 figures

  4. arXiv:2002.09635  [pdf, other

    eess.IV cs.CV cs.LG

    Towards Label-Free 3D Segmentation of Optical Coherence Tomography Images of the Optic Nerve Head Using Deep Learning

    Authors: Sripad Krishna Devalla, Tan Hung Pham, Satish Kumar Panda, Liang Zhang, Giridhar Subramanian, Anirudh Swaminathan, Chin Zhi Yun, Mohan Rajan, Sujatha Mohan, Ramaswami Krishnadas, Vijayalakshmi Senthil, John Mark S. de Leon, Tin A. Tun, Ching-Yu Cheng, Leopold Schmetterer, Shamira Perera, Tin Aung, Alexandre H. Thiery, Michael J. A. Girard

    Abstract: Since the introduction of optical coherence tomography (OCT), it has been possible to study the complex 3D morphological changes of the optic nerve head (ONH) tissues that occur along with the progression of glaucoma. Although several deep learning (DL) techniques have been recently proposed for the automated extraction (segmentation) and quantification of these morphological changes, the device s… ▽ More

    Submitted 22 February, 2020; originally announced February 2020.

  5. arXiv:1910.02844  [pdf, other

    eess.IV cs.CV cs.LG

    DeshadowGAN: A Deep Learning Approach to Remove Shadows from Optical Coherence Tomography Images

    Authors: Haris Cheong, Sripad Krishna Devalla, Tan Hung Pham, Zhang Liang, Tin Aung Tun, Xiaofei Wang, Shamira Perera, Leopold Schmetterer, Aung Tin, Craig Boote, Alexandre H. Thiery, Michael J. A. Girard

    Abstract: Purpose: To remove retinal shadows from optical coherence tomography (OCT) images of the optic nerve head(ONH). Methods:2328 OCT images acquired through the center of the ONH using a Spectralis OCT machine for both eyes of 13 subjects were used to train a generative adversarial network (GAN) using a custom loss function. Image quality was assessed qualitatively (for artifacts) and quantitatively… ▽ More

    Submitted 7 October, 2019; originally announced October 2019.

  6. Embedded deep learning in ophthalmology: Making ophthalmic imaging smarter

    Authors: Petteri Teikari, Raymond P. Najjar, Leopold Schmetterer, Dan Milea

    Abstract: Deep learning has recently gained high interest in ophthalmology, due to its ability to detect clinically significant features for diagnosis and prognosis. Despite these significant advances, little is known about the ability of various deep learning systems to be embedded within ophthalmic imaging devices, allowing automated image acquisition. In this work, we will review the existing and future… ▽ More

    Submitted 21 February, 2019; v1 submitted 13 October, 2018; originally announced October 2018.

    Comments: This work has been submitted to "Therapeutic Advances in Ophthalmology" for possible publication 17 pages, 5 figures

    MSC Class: 68T45 ACM Class: I.2.10; I.2.11; I.4.5; I.4.9; J.3

    Journal ref: Therapeutic advances in ophthalmology 11 (2019): 2515841419827172

  7. arXiv:1809.10589  [pdf, other

    cs.CV

    A Deep Learning Approach to Denoise Optical Coherence Tomography Images of the Optic Nerve Head

    Authors: Sripad Krishna Devalla, Giridhar Subramanian, Tan Hung Pham, Xiaofei Wang, Shamira Perera, Tin A. Tun, Tin Aung, Leopold Schmetterer, Alexandre H. Thiery, Michael J. A. Girard

    Abstract: Purpose: To develop a deep learning approach to de-noise optical coherence tomography (OCT) B-scans of the optic nerve head (ONH). Methods: Volume scans consisting of 97 horizontal B-scans were acquired through the center of the ONH using a commercial OCT device (Spectralis) for both eyes of 20 subjects. For each eye, single-frame (without signal averaging), and multi-frame (75x signal averaging… ▽ More

    Submitted 27 September, 2018; originally announced September 2018.