Zum Hauptinhalt springen

Showing 1–10 of 10 results for author: Finck, C

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.19421  [pdf, other

    hep-ex physics.ins-det

    The Belle II Detector Upgrades Framework Conceptual Design Report

    Authors: H. Aihara, A. Aloisio, D. P. Auguste, M. Aversano, M. Babeluk, S. Bahinipati, Sw. Banerjee, M. Barbero, J. Baudot, A. Beaubien, F. Becherer, T. Bergauer, F. U. Bernlochner., V. Bertacchi, G. Bertolone, C. Bespin, M. Bessner, S. Bettarini, A. J. Bevan, B. Bhuyan, M. Bona, J. F. Bonis, J. Borah, F. Bosi, R. Boudagga , et al. (186 additional authors not shown)

    Abstract: We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit… ▽ More

    Submitted 4 July, 2024; v1 submitted 26 June, 2024; originally announced June 2024.

    Comments: Editor: F. Forti 170 pages

    Report number: KEK-REPORT-2024-1, BELLE2-REPORT-2024-042

  2. arXiv:2311.13360  [pdf, other

    physics.ins-det hep-ex

    Upgrade of Belle II Vertex Detector with CMOS Pixel Technology

    Authors: M. Schwickardi, M. Babeluk, M. Barbero, J. Baudot, T. Bergauer, G. Bertolone, S. Bettarini, F. Bosi, P. Breugnon, Y. Buch, G. Casarosa, G. Dujany, C. Finck, F. Forti, A. Frey, A. Himmi, C. Irmler, A. Kumar, C. Marinas, M. Massa, L. Massaccesi, J. Mazzora de Cos, M. Minuti, S. Mondal, P. Pangaud , et al. (5 additional authors not shown)

    Abstract: The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MA… ▽ More

    Submitted 12 December, 2023; v1 submitted 22 November, 2023; originally announced November 2023.

    Comments: 8 pages, 8 figures, Proceedings for 24th international Workshop on Radiation Imaging Detectors,25-29 JUNE 20233 Oslo

  3. Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

    Authors: R. Leboucher, K. Adamczyk, L. Aggarwal, H. Aihara, T. Aziz, S. Bacher, S. Bahinipati, G. Batignani, J. Baudot, P. K. Behera, S. Bettarini, T. Bilka, A. Bozek, F. Buchsteiner, G. Casarosa, L. Corona, T. Czank, S. B. Das, G. Dujany, C. Finck, F. Forti, M. Friedl, A. Gabrielli, E. Ganiev, B. Gobbo , et al. (56 additional authors not shown)

    Abstract: The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest… ▽ More

    Submitted 7 September, 2022; originally announced September 2022.

    Comments: 4 pages, The 30th International Workshop on Vertex Detectors

    Journal ref: NIMA, Volume 1033, 2022, 166746

  4. arXiv:2201.12137  [pdf

    physics.ins-det hep-ex

    CMOS pixel sensors optimized for large ionizing dynamic

    Authors: W. Ren, J. Baudot, L. Federici, C. Finck, C. Hu-Guo, M. Kachel, C. -A. Reidel, C. Schui, R. Sefri, E. Spiriti, U. Weber, Y. Zhao

    Abstract: Monolithic active pixel sensors (MAPS) are now well established as a technology for tracking charged particles, especially when low material budget is desirable. For such applications, sensors focus on spatial resolution and pixels with digital output or modest charge measurement ability are well suited. Within the European Union STRONG-2020 project, which focuses on experiments using hadrons, the… ▽ More

    Submitted 24 January, 2022; originally announced January 2022.

    Comments: 4 pages

  5. The Silicon Vertex Detector of the Belle II Experiment

    Authors: G. Dujany, K. Adamczyk, L. Aggarwal, H. Aihara, T. Aziz, S. Bacher, S. Bahinipati, G. Batignani, J. Baudot, P. K. Behera, S. Bettarini, T. Bilka, A. Bozek, F. Buchsteiner, G. Casarosa, L. Corona, T. Czank, S. B. Das, C. Finck, F. Forti, M. Friedl, A. Gabrielli, E. Ganiev, B. Gobbo, S. Halder , et al. (56 additional authors not shown)

    Abstract: In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The S… ▽ More

    Submitted 18 March, 2022; v1 submitted 26 November, 2021; originally announced November 2021.

    Comments: 7 pages, 5 figures, proceedings contribution at the 12th International Conference on Position Sensitive Detectors

  6. arXiv:2010.16251  [pdf, other

    physics.ins-det nucl-ex

    The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system

    Authors: Silvia Biondi, Andrey Alexandrov, Behcet Alpat, Giovanni Ambrosi, Stefano Argirò, Rau Arteche Diaz, Nazarm Bartosik, Giuseppe Battistoni, Nicola Belcari, Elettra Bellinzona, Maria Giuseppina Bisogni, Graziano Bruni, Pietro Carra, Piergiorgio Cerello, Esther Ciarrocchi, Alberto Clozza, Sofia Colombi, Giovanni De Lellis, Alberto Del Guerra, Micol De Simoni, Antonia Di Crescenzo, Benedetto Di Ruzza, Marco Donetti, Yunsheng Dong, Marco Durante , et al. (70 additional authors not shown)

    Abstract: The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim… ▽ More

    Submitted 29 October, 2020; originally announced October 2020.

  7. arXiv:1306.0378  [pdf, other

    nucl-ex physics.med-ph

    Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy

    Authors: J. Dudouet, D. Juliani, J. C. Ang elique, B. Braunn, J. Colin, D. Cussol, Ch. Finck, J. M. Fontbonne, H. Gu erin, P. Henriquet, J. Krimmer, M. Labalme, M. Rousseau, M. G. Saint-Laurent, S. Salvador

    Abstract: During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double… ▽ More

    Submitted 3 June, 2013; originally announced June 2013.

    Comments: Submitted to PRC

    Journal ref: Physical Review C 88 (2013) 024606

  8. arXiv:1304.0173  [pdf, other

    physics.med-ph nucl-ex physics.ins-det

    Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy

    Authors: J. Dudouet, D. Juliani, M. Labalme, J. C. Angélique, B. Braunn, J. Colin, D. Cussol, Ch. Finck, J. M. Fontbonne, H. Guérin, P. Henriquet, J. Krimmer, M. Rousseau, M. G. Saint-Laurent

    Abstract: During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double… ▽ More

    Submitted 31 March, 2013; originally announced April 2013.

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 715 (2013) 98-104

  9. arXiv:1111.5731  [pdf, other

    physics.ins-det nucl-ex

    AGATA - Advanced Gamma Tracking Array

    Authors: S. Akkoyun, A. Algora, B. Alikhani, F. Ameil, G. de Angelis, L. Arnold, A. Astier, A. Ataç, Y. Aubert, C. Aufranc, A. Austin, S. Aydin, F. Azaiez, S. Badoer, D. L. Balabanski, D. Barrientos, G. Baulieu, R. Baumann, D. Bazzacco, F. A. Beck, T. Beck, P. Bednarczyk, M. Bellato, M. A. Bentley, G. Benzoni , et al. (329 additional authors not shown)

    Abstract: The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the… ▽ More

    Submitted 17 September, 2012; v1 submitted 24 November, 2011; originally announced November 2011.

    Comments: This version contains a correction of a typing error in the caption of Fig. 2. The DOI to the article published in Nucl. Instr. Meth A was also added

  10. A Large Area Timing RPC

    Authors: A. Blanco, R. Ferreira-Marques, Ch. Finck, P. Fonte, A. Gobbi, A. Policarpo, M. Rozas

    Abstract: A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A timing resolution between 50 and 75 ps sigma with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95% was attained over the whole active area,… ▽ More

    Submitted 26 March, 2001; originally announced March 2001.

    Comments: 22 pages, 10 figures (submitted to Nucl. Instr. and Meth.)

    Report number: LIP/01-04

    Journal ref: ICFA Instrum.Bull. 23 (2001) 1-15; Nucl.Instrum.Meth. A485 (2002) 328-342