-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
New measurement of the $1S-3S$ transition frequency of hydrogen: contribution to the proton charge radius puzzle
Authors:
Hélène Fleurbaey,
Sandrine Galtier,
Simon Thomas,
Marie Bonnaud,
Lucile Julien,
François Biraben,
François Nez,
Michel Abgrall,
Jocelyne Guéna
Abstract:
We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The proton charge radius deduced from this measurement, $r_\text{p}=0.877(13)$ fm, is in very good agreement with the current CODATA-recommended value. This result con…
▽ More
We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The proton charge radius deduced from this measurement, $r_\text{p}=0.877(13)$ fm, is in very good agreement with the current CODATA-recommended value. This result contributes to the ongoing search to solve the proton charge radius puzzle, which arose from a discrepancy between the CODATA value and a more precise determination of $r_\text{p}$ from muonic hydrogen spectroscopy.
△ Less
Submitted 27 April, 2018; v1 submitted 26 January, 2018;
originally announced January 2018.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Authors:
Jérôme Lodewyck,
Sławomir Bilicki,
Eva Bookjans,
Jean-Luc Robyr,
Chunyan Shi,
Grégoire Vallet,
Rodolphe Le Targat,
Daniele Nicolodi,
Yann Le Coq,
Jocelyne Guéna,
Michel Abgrall,
Peter Rosenbusch,
Sébastien Bize
Abstract:
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th…
▽ More
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
△ Less
Submitted 12 May, 2016;
originally announced May 2016.
-
Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
Authors:
A. Hees,
J. Guéna,
M. Abgrall,
S. Bize,
P. Wolf
Abstract:
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine tr…
▽ More
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine transition frequency ratio. We find no signal consistent with a scalar dark matter candidate but provide improved constraints on the coupling of the putative scalar field to standard matter. Our limits are complementary to previous results that were only sensitive to the fine structure constant, and improve them by more than an order of magnitude when only a coupling to electromagnetism is assumed.
△ Less
Submitted 28 July, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Authors:
R Tyumenev,
M Favier,
S Bilicki,
E Bookjans,
R Le Targat,
J Lodewyck,
D Nicolodi,
Y Le Coq,
M Abgrall,
J Guéna,
L De Sarlo,
S Bize
Abstract:
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta…
▽ More
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.
△ Less
Submitted 13 November, 2016; v1 submitted 7 March, 2016;
originally announced March 2016.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Contributing to TAI with a Secondary Representation of the SI Second
Authors:
Jocelyne Guéna,
Michel Abgrall,
André Clairon,
Sébastien Bize
Abstract:
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in th…
▽ More
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in the SI system, i.e. against primary frequency standards, down to a fractional uncertainty of $4.4\times 10^{-16}$, and on the establishment of the recommended value for the $^{87}$Rb hyperfine transition by the CIPM. We also report on the process that led to the participation of the FO2-Rb frequency standard to $Circular~T$ and to the elaboration of TAI. This participation enables us to demonstrate absolute frequency measurement directly in terms of the SI second realized by the TAI ensemble with a statistical uncertainty of $1.1\times 10^{-16}$, therefore at the limit allowed by the accuracy of primary frequency standards. This work constitutes a demonstration of how other secondary representations, based on optical transitions, could also be used for TAI, and an investigation of a number of issues relevant to a future redefinition of the SI second.
△ Less
Submitted 29 January, 2014;
originally announced January 2014.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
Authors:
J. Guéna,
P. Rosenbusch,
Ph. Laurent,
M. Abgrall,
D. Rovera,
M. Lours,
G. Santarelli,
M. E. Tobar,
S. Bize,
A. Clairon
Abstract:
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency meas…
▽ More
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the absolute 87Rb hyperfine frequency.
△ Less
Submitted 3 January, 2013;
originally announced January 2013.
-
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Peter Rosenbusch,
Michael E. Tobar,
Philippe Laurent,
André Clairon,
Sébastien Bize
Abstract:
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H.…
▽ More
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.
△ Less
Submitted 22 August, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Progress in Atomic Fountains at LNE-SYRTE
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Philippe Laurent,
Baptiste Chupin,
Michel Lours,
Giorgio Santarelli,
Peter Rosenbusch,
Michael E. Tobar,
Ruoxin Li,
Kurt Gibble,
André Clairon,
Sébastien Bize
Abstract:
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed…
▽ More
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
Authors:
J. J. McFerran,
L. Yi,
S. Mejri,
S. Di Manno,
W. Zhang,
J. Guéna,
Y. Le Coq,
S. Bize
Abstract:
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are load…
▽ More
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are loaded from a single stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. The frequency of the clock transition is found to be 1 128 575 290 808 162.0 +/-6.4 (sys.) +/-0.3 (stat.) Hz (fractional uncertainty = 5.7x10^(-15)). Neither an atom number nor second order Zeeman dependence have yet to be detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing and detection.
△ Less
Submitted 17 January, 2012;
originally announced January 2012.
-
Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
Authors:
Jocelyne Guéna,
Ruoxin Li,
Kurt Gibble,
Sébastien Bize,
André Clairon
Abstract:
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10…
▽ More
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.
△ Less
Submitted 8 March, 2011;
originally announced March 2011.
-
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
Authors:
J. Millo,
M. Abgrall,
M. Lours,
E. M. L. English,
H. Jiang,
J. Guena,
A. Clairon,
S. Bize,
Y. Le Coq,
G. Santarelli,
M. E. Tobar
Abstract:
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used t…
▽ More
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.
△ Less
Submitted 23 January, 2009;
originally announced January 2009.
-
An experimental study of intermodulation effects in an atomic fountain frequency standard
Authors:
Jocelyne Guéna,
Gregor Dudle,
Pierre Thomann
Abstract:
The short-term stability of passive atomic frequency standards, especially in pulsed operation, is often limited by local oscillator noise via intermodulation effects. We present an experimental demonstration of the intermodulation effect on the frequency stability of a continuous atomic fountain clock where, under normal operating conditions, it is usually too small to observe. To achieve this,…
▽ More
The short-term stability of passive atomic frequency standards, especially in pulsed operation, is often limited by local oscillator noise via intermodulation effects. We present an experimental demonstration of the intermodulation effect on the frequency stability of a continuous atomic fountain clock where, under normal operating conditions, it is usually too small to observe. To achieve this, we deliberately degrade the phase stability of the microwave field interrogating the clock transition. We measure the frequency stability of the locked, commercial-grade local oscillator, for two modulation schemes of the microwave field: square-wave phase modulation and square-wave frequency modulation. We observe a degradation of the stability whose dependence with the modulation frequency reproduces the theoretical predictions for the intermodulation effect. In particular no observable degradation occurs when this frequency equals the Ramsey linewidth. Additionally we show that, without added phase noise, the frequency instability presently equal to 2x10-13 at 1s, is limited by atomic shot-noise and therefore could be reduced were the atomic flux increased.
△ Less
Submitted 20 February, 2007;
originally announced February 2007.
-
Pump-probe measurement of atomic parity violation in caesium with a precision of 2.6%
Authors:
Michel Lintz,
Jocelyne Guéna,
Marie-Anne Bouchiat
Abstract:
We present the atomic parity violation measurements made in Cs vapour using a pump-probe scheme. After pulsed excitation of the 6S-7S forbidden transition in the presence of a longitudinal electric field, a laser beam resonant with one of the 7S-6P transitions stimulates the 7S atom emission for a duration of 20 ns. The polarisation of the amplified probe beam is analysed. A seven-fold signature…
▽ More
We present the atomic parity violation measurements made in Cs vapour using a pump-probe scheme. After pulsed excitation of the 6S-7S forbidden transition in the presence of a longitudinal electric field, a laser beam resonant with one of the 7S-6P transitions stimulates the 7S atom emission for a duration of 20 ns. The polarisation of the amplified probe beam is analysed. A seven-fold signature allows discrimination of the parity violating linear dichroism, and real-time calibration by a similar, known, parity conserving linear dichroism. The zero-field linear dichroism signal due to the magnetic dipole transition moment is observed for the first time, and used for in-situ determination of the electric field. The result, ImE1^{pv}= (-808+/- 21) 10^{-14} ea\_{0}, is in perfect agreement with the corresponding, more precise measurement obtained by the Boulder group. A transverse field configuration with large probe amplification could bring atomic parity violation measurements to the 0.1% accuracy level.
△ Less
Submitted 6 October, 2006;
originally announced October 2006.
-
An Alkali-Vapor Cell with Metal Coated Windows for Efficient Application of an Electric Field
Authors:
David Sarkisyan,
A. S. Sarkisyan,
Jocelyne Guéna,
Michel Lintz,
Marie-Anne Bouchiat
Abstract:
We describe the implementation of a cylindrical T-shaped alkali-vapor cell for laser spectroscopy in the presence of a longitudinal electric field. The two windows are used as two electrodes of the high-voltage assembly, which is made possible by a metallic coating which entirely covers the inner and outer sides of the windows except for a central area to let the laser beams in and out of the ce…
▽ More
We describe the implementation of a cylindrical T-shaped alkali-vapor cell for laser spectroscopy in the presence of a longitudinal electric field. The two windows are used as two electrodes of the high-voltage assembly, which is made possible by a metallic coating which entirely covers the inner and outer sides of the windows except for a central area to let the laser beams in and out of the cell. This allows very efficient application of the electric field, up to 2 kV/cm in a rather dense superheated vapor, even when significant photoemission takes place at the windows during pulsed laser irradiation. The body of the cell is made of sapphire or alumina ceramic to prevent large currents resulting from surface conduction observed in cesiated glass cells. The technique used to attach the monocrystalline sapphire windows to the cell body causes minimal stress birefringence in the windows. In addition, reflection losses at the windows can be made very small. The vapor cell operates with no buffer gas and has no magnetic part. The use of this kind of cell has resulted in an improvement of the signal-to-noise ratio in the measurement of Parity Violation in cesium vapor underway at ENS, Paris. The technique can be applied to other situations where a brazed assembly would give rise to unacceptably large birefringence in the windows.
△ Less
Submitted 4 April, 2005;
originally announced April 2005.
-
Atomic Parity Violation : Principles, Recent Results, Present Motivations
Authors:
Jocelyne Guéna,
Michel Lintz,
Marie-Anne Bouchiat
Abstract:
We review the progress made in the determination of the weak charge, Q\_w, of the cesium nucleus which raises the status of Atomic Parity Violation measurements to that of a precision electroweak test. Not only is it necessary to have a precision measurement of the electroweak asymmetry in the highly forbidden 6S-7S transition, but one also needs a precise calibration procedure. The 1999 precisi…
▽ More
We review the progress made in the determination of the weak charge, Q\_w, of the cesium nucleus which raises the status of Atomic Parity Violation measurements to that of a precision electroweak test. Not only is it necessary to have a precision measurement of the electroweak asymmetry in the highly forbidden 6S-7S transition, but one also needs a precise calibration procedure. The 1999 precision measurement by the Boulder group implied a 2.5 sigma deviation of Q\_w from the theoretical prediction. This triggered many particle physicist suggestions as well as examination by atomic theoretical physicists of several sources of corrections. After about three years the disagreement was removed without appealing to "New Physics". Concurrently, an original experimental approach was developed in our group for more than a decade. It is based on detection by stimulated emission with amplification of the left- right asymmetry. We present our decisive, recent progress together with our latest results. We emphasize the important impact for electroweak theory, of future measurements in cesium possibly pushed to the 0.1% level. Other possible approaches are currently explored in several atoms.
△ Less
Submitted 17 March, 2005;
originally announced March 2005.
-
Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection
Authors:
J. Guéna,
M. Lintz,
M. -A. Bouchiat
Abstract:
We exploit the process of asymmetry amplification by stimulated emission which provides an original method for parity violation (PV) measurements in a highly forbidden atomic transition. The method involves measurements of a chiral, transient, optical gain of a cesium vapor on the 7S-6P_{3/2} transition, probed after it is excited by an intense, linearly polarized, collinear laser, tuned to reso…
▽ More
We exploit the process of asymmetry amplification by stimulated emission which provides an original method for parity violation (PV) measurements in a highly forbidden atomic transition. The method involves measurements of a chiral, transient, optical gain of a cesium vapor on the 7S-6P_{3/2} transition, probed after it is excited by an intense, linearly polarized, collinear laser, tuned to resonance for one hyperfine line of the forbidden 6S-7S transition in a longitudinal electric field. We report here a 3.5 fold increase, of the one-second-measurement sensitivity, and subsequent reduction by a factor of 3.5 of the statistical accuracy compared with our previous result [J. Guéna et al., Phys. Rev. Lett. 90, 143001 (2003)]. Decisive improvements to the set-up include an increased repetition rate, better extinction of the probe beam at the end of the probe pulse and, for the first time to our knowledge, the following: a polarization-tilt magnifier, quasi-suppression of beam reflections at the cell windows, and a Cs cell with electrically conductive windows. We also present real-time tests of systematic effects, consistency checks on the data, as well as a 1% accurate measurement of the electric field seen by the atoms, from atomic signals. PV measurements performed in seven different vapor cells agree within the statistical error. Our present result is compatible with the more precise Boulder result within our present relative statistical accuracy of 2.6%, corresponding to a 2 \times 10^{-13} atomic-unit uncertainty in E_1^{pv}. Theoretical motivations for further measurements are emphasized and we give a brief overview of a recent proposal that would allow the uncertainty to be reduced to the 0.1% level by creating conditions where asymmetry amplification is much greater.
△ Less
Submitted 4 March, 2005; v1 submitted 2 December, 2004;
originally announced December 2004.
-
Demonstration of an optical polarization magnifier with low birefringence
Authors:
Michel Lintz,
Jocelyne Guena,
Marie-Anne Bouchiat,
Dominique Chauvat
Abstract:
In any polarimetric measurement technique, enhancing the laser polarization change of a laser beam before it reaches the analyzer can help in improving the sensitivity. This can be performed using an optical component having a large linear dichroism, the enhancement factor being equal to the square root of the ratio of the two transmission factors. A pile of parallel plates at Brewster incidence…
▽ More
In any polarimetric measurement technique, enhancing the laser polarization change of a laser beam before it reaches the analyzer can help in improving the sensitivity. This can be performed using an optical component having a large linear dichroism, the enhancement factor being equal to the square root of the ratio of the two transmission factors. A pile of parallel plates at Brewster incidence looks appropriate for realizing such a polarization magnifier. In this paper, we address the problem raised by the interference in the plates and between the plates, which affects the measurement by giving rise to birefringence. We demonstrate that wedged plates provide a convenient and efficient way to avoid this interference. We have implemented and characterized devices with 4 and 6 wedged plates at Brewster incidence which have led to a decisive improvement of the signal to noise ratio in our ongoing Parity Violation measurement.
△ Less
Submitted 22 March, 2005; v1 submitted 7 October, 2004;
originally announced October 2004.
-
Proposal for high-precision Atomic Parity Violation measurements using amplification of the asymmetry by stimulated emission in a transverse E and B field pump-probe experiment
Authors:
J. Guéna,
M. Lintz,
M. A Bouchiat
Abstract:
Amplification by stimulated emission of radiation provides an intriguing means for increasing the sensitivity of Atomic Parity Violation (APV) measurements in a pump-probe configuration well adapted to the 6S-7S cesium transition. It takes advantage of the large number of atoms excited along the path of the pump beam. In the longitudinal E-field configuration currently exploited in an ongoing AP…
▽ More
Amplification by stimulated emission of radiation provides an intriguing means for increasing the sensitivity of Atomic Parity Violation (APV) measurements in a pump-probe configuration well adapted to the 6S-7S cesium transition. It takes advantage of the large number of atoms excited along the path of the pump beam. In the longitudinal E-field configuration currently exploited in an ongoing APV measurement, this number is limited only by the total voltage sustainable by the Cs vapor. In order to overcome this limit, we consider, both theoretically and experimentally, the possibility of performing the measurements in a transverse E-field configuration requiring a much lower voltage. We discuss the necessarily different nature of the observable and the magnetoelectric optical effects entering into play. They condition modifications of the experimental configuration with, in particular, the application of a transverse magnetic field. We suggest the possibility of rotating the transverse direction of the fields so as to suppress systematic effects. With a long interaction length, a precision reaching 0.1 percent in a quantum noise limited measurement can be expected, now limited only by the necessity of operating below the threshold of spontaneous superradiant emission of the excited medium. If we approached this limit, however, we could greatly amplify the asymmetry using triggered superradiance.
△ Less
Submitted 30 March, 2004;
originally announced March 2004.
-
Cylindrical Symmetry Discrimination of Magnetoelectric Optical Systematic Effects in a Pump-probe Atomic Parity Violation Experiment
Authors:
M-A. Bouchiat,
J. Guéna,
M. Lintz
Abstract:
A pump-probe atomic parity violation (APV) experiment performed in a longitudinal electric field, provides a signal breaking mirror symmetry while preserving the cylindrical symmetry of the set-up. The excited vapor acts on the probe beam as a linear dichroic amplifier, imprinting a very specific signature on the detected signal. Our differential polarimeter is oriented to yield a null result un…
▽ More
A pump-probe atomic parity violation (APV) experiment performed in a longitudinal electric field, provides a signal breaking mirror symmetry while preserving the cylindrical symmetry of the set-up. The excited vapor acts on the probe beam as a linear dichroic amplifier, imprinting a very specific signature on the detected signal. Our differential polarimeter is oriented to yield a null result unless the excited atoms are endowed with a chirality of some kind. Ideally, only the APV (E-odd) and the calibration (E-even) signals contribute to a chiral atomic response, a situation highly favourable to the detection of a tiny effect. In the present work we give a thorough analysis of possible unwanted defects like stray transverse fields or misalignments which would spoil the ideal set-up and lead to chiral systematics. A possible way to suppress such effects is to perform global rotations of the experiment by incremental steps of 45 degrees, leaving both stray fields and misalignments unaltered. The conspiration of at least two defects is necessary to affect the E-odd polarimeter signal. The transverse nature of the defects manifests itself by an azimuthal cosine square modulation. The harmful systematics are those which survive the averaging over four successive configurations. They require the presence of a stray transverse electric field, which can be determined and eventually minimized by auxiliary measurements of the systematic effects, amplified by applying a known external magnetic field. Transverse stray magnetic fields must be compensated by a similar procedure. We also propose statistical correlation tests as diagnoses of the aforementioned systematic effects.
△ Less
Submitted 20 November, 2003;
originally announced November 2003.
-
Prospects for Forbidden-Transition Spectroscopy and Parity Violation Measurements using a Beam of Cold Stable or Radioactive Atoms
Authors:
S. Sanguinetti,
J. Guéna,
M. Lintz,
Ph. Jacquier,
A. Wasan,
M-A. Bouchiat
Abstract:
Laser cooling and trapping offers the possibility of confining a sample of radioactive atoms in free space. Here, we address the question of how best to take advantage of cold atom properties to perform the observation of as highly forbidden a line as the 6S-7S Cs transition for achieving, in the longer term, Atomic Parity Violation measurements in radioactive alkali isotopes. Another point at i…
▽ More
Laser cooling and trapping offers the possibility of confining a sample of radioactive atoms in free space. Here, we address the question of how best to take advantage of cold atom properties to perform the observation of as highly forbidden a line as the 6S-7S Cs transition for achieving, in the longer term, Atomic Parity Violation measurements in radioactive alkali isotopes. Another point at issue is whether one might do better with stable, cold atoms than with thermal atoms. To compensate for the large drawback of the small number of atoms available in a trap, one must take advantage of their low velocity. To lengthen the time of interaction with the excitation laser, we suggest choosing a geometry where the laser beam exciting the transition is colinear to a slow, cold atomic beam, either extracted from a trap or prepared by Zeeman slowing. We also suggest a new observable physical quantity manifesting APV, which presents several advantages:specificity, efficiency of detection, possibility of direct calibration by a parity conserving quantity of a similar nature. It is well adapted to a configuration where the cold atomic beam passes through two regions of transverse, crossed electric fields, leading both to differential measurements and to strong reduction of the contributions from the M_1-Stark interference signals, potential sources of systematics in APV measurements. Our evaluation of signal to noise ratios shows that with available techniques, measurements of transition amplitudes, important as required tests of Atomic Theory should be possible in cesium 133 with a statistical precision of 1/1000 and probably also in Fr isotopes for production rates of 10^6 Fr atoms/s.
△ Less
Submitted 2 March, 2003;
originally announced March 2003.
-
A new Manifestation of Atomic Parity Violation in Cesium: a Chiral Optical Gain induced by linearly polarized 6S-7S Excitation
Authors:
J. Guéna,
D. Chauvat,
Ph. Jacquier,
E. Jahier,
M. Lintz,
A. V. Papoyan,
S. Sanguinetti,
D. Sarkisyan,
A. Wasan,
M. A. Bouchiat
Abstract:
We have detected, by using stimulated emission, an Atomic Parity Violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S - 6P$_{3/2}$ transition,consecutive to linearly polarized 6S-7S excitation. We demonstrate the validity of this detection method of APV, by presenting a 9% accurate measurement of expected sign and magnitude. We underline several advantages of this ent…
▽ More
We have detected, by using stimulated emission, an Atomic Parity Violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S - 6P$_{3/2}$ transition,consecutive to linearly polarized 6S-7S excitation. We demonstrate the validity of this detection method of APV, by presenting a 9% accurate measurement of expected sign and magnitude. We underline several advantages of this entirely new approach in which the cylindrical symmetry of the set-up can be fully exploited. Future measurements at the percent level will provide an important cross-check of an existing more precise result obtained by a different method.
△ Less
Submitted 17 October, 2002;
originally announced October 2002.