-
Yet anOther Dose Algorithm (YODA) for independent computations of dose and dose changes due to anatomical changes
Authors:
Tiberiu Burlacu,
Danny Lathouwers,
Zoltán Perkó
Abstract:
$\textbf{Purpose:}$ To assess the viability of a physics-based, deterministic and adjoint-capable algorithm for performing treatment planning system independent dose calculations and for computing dosimetric differences caused by anatomical changes.
$\textbf{Methods:}…
▽ More
$\textbf{Purpose:}$ To assess the viability of a physics-based, deterministic and adjoint-capable algorithm for performing treatment planning system independent dose calculations and for computing dosimetric differences caused by anatomical changes.
$\textbf{Methods:}$ A semi-numerical approach is employed to solve two partial differential equations for the proton phase-space density which determines the deposited dose. Lateral hetereogeneities are accounted for by an optimized (Gaussian) beam splitting scheme. Adjoint theory is applied to approximate the change in the deposited dose caused by a new underlying patient anatomy.
$\textbf{Results:}$ The quality of the dose engine was benchmarked through three-dimensional gamma index comparisons against Monte Carlo simulations done in TOPAS. The worst passing rate for the gamma index with (1 mm, 1 %, 10 % dose cut-off) criteria is 95.62 %. The effect of delivering treatment plans on repeat CTs was also tested. For a non-robustly optimized plan the adjoint component was accurate to 6.2 % while for a robustly optimized plan it was accurate to 1 %.
$\textbf{Conclusions:}$ YODA is capable of accurate dose computations in both single and multi spot irradiations when compared to TOPAS. Moreover, it is able to compute dosimetric differences due to anatomical changes with small to moderate errors thereby facilitating its use for patient-specific quality assurance in online adaptive proton therapy.
△ Less
Submitted 1 April, 2024;
originally announced April 2024.
-
A Geant4 Based Simulation Platform of the HollandPTC R&D Proton Beamline for Radiobiological Studies
Authors:
C. F. Groenendijk,
M. Rovituso,
D. Lathouwers,
J. M. C. Brown
Abstract:
A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configur…
▽ More
A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configuration. Three different experimental proton datasets (70 MeV, 150 MeV, and 240 MeV) of the pencil beam envelope evolution in free air and depth-dose profiles in water were used to develop a set of individual parameter surrogate functions to enable the modelling of the non-symmetrical Gaussian pencil beam properties with only the ProBeam isochronous cyclotron mean extraction proton energy as input. This refined beam model was then benchmarked with respect to three independent experimental datasets of the R&D beamline operating in both a pencil beam configuration at 120 and 200 MeV, and passively scattered field configuration at 150 MeV. It was shown that the G4HPTC-R&D simulation platform can reproduce the pencil beam envelope evolution in free air and depth-dose profiles to within an accuracy on the order of $\pm$5% for all tested energies, and that it was able to reproduce the 150 MeV passively scattered field to the specifications need for clinical and radiobiological applications.
△ Less
Submitted 30 May, 2023; v1 submitted 20 February, 2023;
originally announced February 2023.
-
Characterisation of the HollandPTC R&D proton beamline for physics and radiobiology studies
Authors:
M. Rovituso,
C. F. Groenendijk,
E. van der Wal,
W. van Burik,
A. Ibrahimi,
H. Rituerto Prieto,
J. M. C. Brown,
U. Weber,
Y. Simeonov,
M. Fontana,
D. Lathouwers,
M. van Vulpen,
M. Hoogeman
Abstract:
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). In addition, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research f…
▽ More
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). In addition, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research facilities including a versatile R&D proton beamline for various types of biologically and technologically oriented research. In this work, we present the characterization of the R&D proton beam line of HollandPTC. Its pencil beam mimics the one used for clinical IMPT, with energy ranging from 70 up to 240 MeV, which has been characterized in terms of shape, size, and intensity. For experiments that need a uniform field in depth and lateral directions, a dual ring passive scattering system has been designed, built, and characterized. With this system, field sizes between 2x2 cm2 and 20x20 cm2 with 98% uniformity are produced with dose rates ranging from 0.5 Gy/min up to 9 Gy/min. The unique and customized support of the dual ring system allows switching between a pencil beam and a large field in a very simple and fast way, making the HollandPTC R&D proton beam able to support a wide range of different applications.
△ Less
Submitted 20 February, 2023;
originally announced February 2023.
-
A probabilistic deep learning model of inter-fraction anatomical variations in radiotherapy
Authors:
Oscar Pastor-Serrano,
Steven Habraken,
Mischa Hoogeman,
Danny Lathouwers,
Dennis Schaart,
Yusuke Nomura,
Lei Xing,
Zoltán Perkó
Abstract:
In radiotherapy, the internal movement of organs between treatment sessions causes errors in the final radiation dose delivery. Motion models can be used to simulate motion patterns and assess anatomical robustness before delivery. Traditionally, such models are based on principal component analysis (PCA) and are either patient-specific (requiring several scans per patient) or population-based, ap…
▽ More
In radiotherapy, the internal movement of organs between treatment sessions causes errors in the final radiation dose delivery. Motion models can be used to simulate motion patterns and assess anatomical robustness before delivery. Traditionally, such models are based on principal component analysis (PCA) and are either patient-specific (requiring several scans per patient) or population-based, applying the same deformations to all patients. We present a hybrid approach which, based on population data, allows to predict patient-specific inter-fraction variations for an individual patient. We propose a deep learning probabilistic framework that generates deformation vector fields (DVFs) warping a patient's planning computed tomography (CT) into possible patient-specific anatomies. This daily anatomy model (DAM) uses few random variables capturing groups of correlated movements. Given a new planning CT, DAM estimates the joint distribution over the variables, with each sample from the distribution corresponding to a different deformation. We train our model using dataset of 312 CT pairs from 38 prostate cancer patients. For 2 additional patients (22 CTs), we compute the contour overlap between real and generated images, and compare the sampled and ground truth distributions of volume and center of mass changes. With a DICE score of 0.86 and a distance between prostate contours of 1.09 mm, DAM matches and improves upon PCA-based models. The distribution overlap further indicates that DAM's sampled movements match the range and frequency of clinically observed daily changes on repeat CTs. Conditioned only on a planning CT and contours of a new patient without any pre-processing, DAM can accurately predict CTs seen during following treatment sessions, which can be used for anatomically robust treatment planning and robustness evaluation against inter-fraction anatomical changes.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
A deterministic adjoint-based semi-analytical algorithm for fast response change computations in proton therapy
Authors:
Tiberiu Burlacu,
Danny Lathouwers,
Zoltán Perkó
Abstract:
In this paper we propose a solution to the need for a fast particle transport algorithm in Online Adaptive Proton Therapy capable of cheaply, but accurately computing the changes in patient dose metrics as a result of changes in the system parameters. We obtain the proton phase-space density through the product of the numerical solution to the one-dimensional Fokker-Planck equation and the analyti…
▽ More
In this paper we propose a solution to the need for a fast particle transport algorithm in Online Adaptive Proton Therapy capable of cheaply, but accurately computing the changes in patient dose metrics as a result of changes in the system parameters. We obtain the proton phase-space density through the product of the numerical solution to the one-dimensional Fokker-Planck equation and the analytical solution to the Fermi-Eyges equation. Moreover, a corresponding adjoint system was derived and solved for the adjoint flux. The proton phase-space density together with the adjoint flux and the metric (chosen as the energy deposited by the beam in a variable region of interest) allowed assessing the accuracy of our algorithm to different perturbation ranges in the system parameters and regions of interest. The algorithm achieved negligible errors ($1.1 \times 10^{-6}$ $\%$ to $3.6 \times 10^{-3}$ $\%$) for small perturbation ranges ($-40 \text{ HU to } 40 \text{ HU}$) and small to moderate errors ($3 \text{ $\%$ to } 17 \text{ $\%$}$) -- in line with the well-known limitation of adjoint approaches -- for large perturbation ranges ($-400 \text{ HU to } 400 \text{ HU}$) in the case of most clinical interest where the region of interest surrounds the Bragg peak. Given these results coupled with the capability of further improving the timing performance it can be concluded that our algorithm presents a viable solution for the specific purpose of Online Adaptive Proton Therapy.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.