-
A molecular dynamics simulation of the abrupt changes in the thermodynamic properties of water after formation of nano-bubbles / nano-cavities induced by passage of charged particles
Authors:
Ramin Abolfath,
Niayesh Afshordi,
Sohrab Rahvar,
Adri van Duin,
Martin Radler,
Reza Taleei,
Katia Parodi,
Julie Lascaud,
Radhe Mohan
Abstract:
We present a multi-scale formalism that accounts for the formation of nano-scale bubbles/cavities owing to a burst of water molecules after the passage of high energy charged particles that leads to the formation of hot non-ionizing excitations or thermal spikes (TS). We demonstrate the coexistence of a rapidly growing condensed state of water and a hot spot that forms a stable state of diluted wa…
▽ More
We present a multi-scale formalism that accounts for the formation of nano-scale bubbles/cavities owing to a burst of water molecules after the passage of high energy charged particles that leads to the formation of hot non-ionizing excitations or thermal spikes (TS). We demonstrate the coexistence of a rapidly growing condensed state of water and a hot spot that forms a stable state of diluted water at high temperatures and pressures, possibly at a supercritical phase. Depending on the temperature of TS, the thin shell of a highly dense state of water grows by three to five times the speed of sound in water, forming a thin layer of shock wave (SW) buffer, wrapping around the nano-scale cylindrical symmetric cavity. The stability of the cavity, as a result of the incompressibility of water at ambient conditions and the surface tension, allows the transition of supersonic SW to a subsonic contact discontinuity and dissipation to thermo-acoustic sound waves. We further study the mergers of nanobubbles that lead to fountain-like or jet-flow structures at the collision interface. We introduce a time delay in the nucleation of nano-bubbles, a novel mechanism, responsible for the growth and stability of much larger or even micro-bubbles, possibly relevant to FLASH ultra-high dose rate (UHDR). The current study is potentially significant at FLASH-UHDRs. Our analysis predicts the black-body radiation from the transient supercritical state of water localized in nano-cavities wrapping around the track of charged particles can be manifested in the (indirect) water luminescence spectrum.
△ Less
Submitted 9 March, 2024;
originally announced March 2024.
-
A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy
Authors:
Andrew Chacon,
Harley Rutherford,
Akram Hamato,
Munetaka Nitta,
Fumihiko Nishikido,
Yuma Iwao,
Hideaki Tashima,
Eiji Yoshida,
Go Akamatsu,
Sodai Takyu,
Han Gyu Kang,
Daniel R. Franklin,
Katia Parodi,
Taiga Yamaya,
Anatoly Rosenfeld,
Susanna Guatelli,
Mitra Safavi-Naeini
Abstract:
Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.
Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion be…
▽ More
Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.
Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent $^{11}$C, $^{10}$C and $^{15}$O radionuclides contributions in each voxel were determined from the extracted time activity curves. Experiments were simulated in Geant4 Monte Carlo versions 10-11.1, with three different fragmentation models: binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 combinations. Total/parent isotope positron annihilation yields were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Depth of maximum/distal 50\% peak position yield were also compared.
Results: Performance varied considerably across versions and models, with no one best predicting all positron-emitting fragments. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50\%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions. Conclusions: Best spatial prediction of annihilation yield and positron-emitting fragment production during carbon and oxygen ion therapy was found to be 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.
△ Less
Submitted 14 April, 2024; v1 submitted 5 February, 2024;
originally announced February 2024.
-
Range margin reduction in carbon ion therapy: potential benefits of using radioactive ion beams
Authors:
Olga Sokol,
Laura Cella,
Daria Boscolo,
Felix Horst,
Caterina Oliviero,
Roberto Pacelli,
Giuseppe Palma,
Micol De Simoni,
Manuel Conson,
Mara Caroprese,
Ulrich Weber,
Christian Graeff,
Katia Parodi,
Marco Durante
Abstract:
Radiotherapy with heavy ions, in particular, 12C beams, is one of the most advanced forms of cancer treatment. Sharp dose gradients and high biological effectiveness in the target region make them an ideal tool to treat deep-seated and radioresistant tumors, however, at the same time, sensitive to small errors in the range prediction. Safety margins are added to the tumor volume to mitigate these…
▽ More
Radiotherapy with heavy ions, in particular, 12C beams, is one of the most advanced forms of cancer treatment. Sharp dose gradients and high biological effectiveness in the target region make them an ideal tool to treat deep-seated and radioresistant tumors, however, at the same time, sensitive to small errors in the range prediction. Safety margins are added to the tumor volume to mitigate these uncertainties and ensure its uniform coverage, but during the irradiation they lead to unavoidable damage to the surrounding healthy tissue. To fully exploit the benefits of a sharp Bragg peak, a large effort is put into establishing precise range verification methods for the so-called image-guided radiotherapy. Despite positron emission tomography being widely in use for this purpose in 12C ion therapy, the low count rates, biological washout, and broad shape of the activity distribution still limit its precision to a few millimeters. Instead, radioactive beams used directly for treatment would yield an improved signal and a closer match with the dose fall-off, potentially enabling precise in vivo beam range monitoring. We have performed a treatment planning study to estimate the possible impact of the reduced range uncertainties, enabled by radioactive 11C beams treatments, on sparing critical organs in the tumor proximity. We demonstrate that (i) annihilation maps for 11C ions can in principle reflect even millimeter shifts in dose distributions in the patient, (ii) outcomes of treatment planning with 11C beams are significantly improved in terms of meeting the constraints for the organs at risk compared to 12C plans, and (iii) less severe toxicities for serial and parallel critical organs can be expected following 11C treatment with reduced range uncertainties, compared to 12C treatments.
△ Less
Submitted 10 October, 2022;
originally announced October 2022.
-
First Tests of the I-BEAT Detector as Primary Monitor for Target Normal Sheath Accelerated Protons
Authors:
F. Balling,
S. Gerlach,
A. -K. Schmidt,
V. Bagnoud,
J. Hornung,
B. Zielbauer,
K. Parodi,
J. Schreiber
Abstract:
The properties of laser-accelerated ion bunches are demanding and require development of suitable beam diagnostics. In particular, the short and intense particle bunches with a broad energy spectrum emitted in conjunction with a strong electromagnetic pulse (EMP) are challenging for conventional and well established monitoring systems. An approach based on measuring the acoustic signals of particl…
▽ More
The properties of laser-accelerated ion bunches are demanding and require development of suitable beam diagnostics. In particular, the short and intense particle bunches with a broad energy spectrum emitted in conjunction with a strong electromagnetic pulse (EMP) are challenging for conventional and well established monitoring systems. An approach based on measuring the acoustic signals of particles depositing their energy in water, referred to as ionoacoustics [https://doi.org/10.1118/1.4905047] was recently developed into Ion-Bunch Energy Acoustic Tracing (I-BEAT)\cite{haffa_i-beat:_2019}. I-BEAT allows online detection of single proton bunches while being cost effective and EMP resistant. A simple water phantom equipped with only one ultrasound transducer positioned on the ion axis allows for reconstructing a rather complex energy spectrum that is typical for (manipulated) laser-accelerated ion bunches. To deduce the lateral bunch properties, additional transducers can be added, for example perpendicular to the ion beam axis. This established setup has been adapted for use closely behind the laser target and tested at the PHELIX laser at GSI. The capability of the system to retrieve information about the broad proton spectrum close to the source despite the harsh conditions has been demonstrated. Future improvements are required, most importantly the increase of dynamic range. Nevertheless, I-BEAT holds promise to evolve into an online diagnostic tool particularly suited for laser-driven source development and optimization at high repetition rates.
△ Less
Submitted 11 November, 2021;
originally announced November 2021.
-
Ionoacoustic detection of swift heavy ions
Authors:
Sebastian Lehrack,
Walter Assmann,
Markus Bender,
Daniel Severin,
Christina Trautmann,
Jörg Schreiber,
Katia Parodi
Abstract:
The maximum energy loss (Bragg peak) located near the end of range is a characteristic feature of ion stopping in matter, which generates an acoustic pulse, if ions are deposited into a medium in adequately short bunches. This so-called ionoacoustic effect has been studied for decades, mainly for astrophysical applications, and it has recently found renewed interest in proton therapy for precise r…
▽ More
The maximum energy loss (Bragg peak) located near the end of range is a characteristic feature of ion stopping in matter, which generates an acoustic pulse, if ions are deposited into a medium in adequately short bunches. This so-called ionoacoustic effect has been studied for decades, mainly for astrophysical applications, and it has recently found renewed interest in proton therapy for precise range measurements in tissue. After detailed preparatory studies with 20 MeV protons at the MLL tandem accelerator, ionoacoustic range measurements were performed in water at the upgraded SIS18 synchrotron of GSI with 238U and 124Xe ion beams of energy about 300 MeV/u, and 12C ions of energy about 200 MeV/u using fast beam extraction to get 1 microsecond pulse lengths. Acoustic signals were recorded in axial geometry by standard piezo-based transducers at a 500 kHz mean frequency and evaluated in both the time and frequency domains. The resulting ranges for the different ions and energies were found to agree with Geant4 simulations as well as previous measurements to better than 1%. Given the high accuracy provided by ionoacoustic range measurements in water and their relative simplicity, we propose this new method for stopping power measurements for heavy ions at GeV energies and above. Our experimental results clearly demonstrate the potential of an ionoacoustic particle monitor especially for very intense heavy ion beams foreseen at future accelerator facilities.
△ Less
Submitted 28 March, 2019;
originally announced March 2019.
-
A novel approach to electron data background treatment in an online wide-angle spectrometer for laser-accelerated ion and electron bunches
Authors:
F. H. Lindner,
J. H. Bin,
F. Englbrecht,
D. Haffa,
P. R. Bolton,
Y. Gao,
J. Hartmann,
P. Hilz,
C. Kreuzer,
T. M. Ostermayr,
T. F. Rösch,
M. Speicher,
K. Parodi,
P. G. Thirolf,
J. Schreiber
Abstract:
Laser-based ion acceleration is driven by electrical fields emerging when target electrons absorb laser energy and consecutively leave the target material. A direct correlation between these electrons and the accelerated ions is thus to be expected and predicted by theoretical models. We report on a modified wide-angle spectrometer allowing the simultaneous characterization of angularly resolved e…
▽ More
Laser-based ion acceleration is driven by electrical fields emerging when target electrons absorb laser energy and consecutively leave the target material. A direct correlation between these electrons and the accelerated ions is thus to be expected and predicted by theoretical models. We report on a modified wide-angle spectrometer allowing the simultaneous characterization of angularly resolved energy distributions of both ions and electrons. Equipped with online pixel detectors, the RadEye1 detectors, the investigation of this correlation gets attainable on a single shot basis. In addition to first insights, we present a novel approach for reliably extracting the primary electron energy distribution from the interfering secondary radiation background. This proves vitally important for quantitative extraction of average electron energies (temperatures) and emitted total charge.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
I-BEAT: New ultrasonic method for single bunch measurement of ion energy distribution
Authors:
Daniel Haffa,
Rong Yang,
Jianhui Bin,
Sebastian Lehrack,
Florian-Emanuel Brack,
Hao Ding,
Franz Englbrecht,
Ying Gao,
Johannes Gebhard,
Max Gilljohann,
Johannes Götzfried,
Jens Hartmann,
Sebastian Herr,
Peter Hilz,
Stephan D. Kraft,
Christian Kreuzer,
Florian Kroll,
Florian H. Lindner,
Josefine Metzkes,
Tobias M. Ostermayr,
Enrico Ridente,
Thomas F. Rösch,
Gregor Schilling,
Hans-Peter Schlenvoigt,
Martin Speicher
, et al. (9 additional authors not shown)
Abstract:
The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its…
▽ More
The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a generalization of the ionoacoustic approach. Featuring compactness, simple operation, indestructibility and high dynamic ranges in energy and intensity, I-BEAT is a promising approach to meet the needs of petawatt-class laser-based ion accelerators. With its capability of completely monitoring a single, focused proton bunch with prompt readout it, is expected to have particular impact for experiments and applications using ultrashort ion bunches in high flux regimes. We demonstrate its functionality using it with two laser-driven ion sources for quantitative determination of the kinetic energy distribution of single, focused proton bunches.
△ Less
Submitted 7 September, 2018;
originally announced September 2018.
-
Imaging in Radiotherapy
Authors:
Katia Parodi
Abstract:
With the continued evolution of modern radiation therapy towards high precision delivery of high therapeutic doses to the tumour while optimally sparing surrounding healthy tissue, imaging becomes a crucial component to identify the intended target, properly position it at the treatment site and, in more advanced research applications, visualize the treatment delivery. This contribution reviews th…
▽ More
With the continued evolution of modern radiation therapy towards high precision delivery of high therapeutic doses to the tumour while optimally sparing surrounding healthy tissue, imaging becomes a crucial component to identify the intended target, properly position it at the treatment site and, in more advanced research applications, visualize the treatment delivery. This contribution reviews the main role of imaging in modern external beam radiation therapy, with special emphasis on emerging ion beam therapy techniques, which aim at exploiting the favourable properties of ion interaction in matter for unprecedented ballistic accuracy in dose delivery
△ Less
Submitted 23 April, 2018;
originally announced April 2018.
-
High-Rate Capable Floating Strip Micromegas
Authors:
Jonathan Bortfeldt,
Michael Bender,
Otmar Biebel,
Helge Danger,
Bernhard Flierl,
Ralf Hertenberger,
Philipp Lösel,
Samuel Moll,
Katia Parodi,
Ilaria Rinaldi,
Alexander Ruschke,
André Zibell
Abstract:
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the ex…
▽ More
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48cm$\times$50cm with 1920 copper anode strips exhibits in 120GeV pion beams a spatial resolution of 50$μ$m at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below $5^\circ$ are observed. Systematic deviations of this $μ$TPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4cm$\times$6.4cm floating strip Micromegas under intense background irradiation of the whole active area with 20MeV protons at a rate of 550kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4cm$\times$6.4cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2MHz and 2GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.
△ Less
Submitted 4 August, 2015;
originally announced August 2015.
-
Sub-millimeter nuclear medical imaging with high sensitivity in positron emission tomography using beta-gamma coincidences
Authors:
C. Lang,
D. Habs,
K. Parodi,
P. G. Thirolf
Abstract:
We present a nuclear medical imaging technique, employing triple-gamma trajectory intersections from beta^+ - gamma coincidences, able to reach sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. This '$γ$-PET' technique draws on specific beta^+ - decaying isotopes, simultaneou…
▽ More
We present a nuclear medical imaging technique, employing triple-gamma trajectory intersections from beta^+ - gamma coincidences, able to reach sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. This '$γ$-PET' technique draws on specific beta^+ - decaying isotopes, simultaneously emitting an additional photon. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to characterize this technique, Monte-Carlo simulations and image reconstructions have been performed. The achievable spatial resolution has been found to reach ca. 0.4 mm (FWHM) in each direction for the visualization of a 22Na point source. Only 40 intersections are sufficient for a reliable sub-millimeter image reconstruction of a point source embedded in a scattering volume of water inside a voxel volume of about 1 mm^3 ('high-resolution mode'). Moreover, starting with an injected activity of 400 MBq for ^76Br, the same number of only about 40 reconstructed intersections are needed in case of a larger voxel volume of 2 x 2 x 3~mm^3 ('high-sensitivity mode'). Requiring such a low number of reconstructed events significantly reduces the required acquisition time for image reconstruction (in the above case to about 140 s) and thus may open up the perspective for a quasi real-time imaging.
△ Less
Submitted 15 February, 2014; v1 submitted 18 May, 2013;
originally announced May 2013.