The AN69 hemofiltration membrane has a decreasing effect on the intracellular diadenosine pentaphosphate concentration of platelets

Kidney Blood Press Res. 2003;26(1):50-4. doi: 10.1159/000069765.

Abstract

Background/aim: The biocompatibility of hemodialysis membranes has a substantial impact on the mortality of patients with end-stage renal failure. In the present study, the effects of hemodialysis on the intracellular amount of diadenosine pentaphosphate (Ap(5)A), a hydrophilic, anionic substance with a low molecular weight, was investigated.

Methods: The intracellular Ap(5)A concentrations were measured before and after hemodialysis using either polyacrylonitrile (AN69; n = 10) or polysulfone (n = 23) membranes. Ap(5)A was isolated from platelets using affinity chromatography and reversed-phase chromatography methods.

Results: The Ap(5)A concentrations were quantified by ultraviolet absorption at 254 nm. The Ap(5)A concentrations were significantly higher in platelets from the patients with end-stage renal failure as compared with the 21 healthy control subjects (136 +/- 50 vs. 9 +/- 6 fg/platelet; mean +/- SEM, p < 0.01). Before hemodialysis, the intracellular Ap(5)A concentrations in platelets from 10 patients with end-stage renal failure using an AN69 membrane were not significantly different from those in platelets from 23 patients using a polysulfone membrane (93 +/- 39 vs. 155 +/- 70 fg/platelet). However, after a hemodialysis session, the intracellular Ap(5)A concentrations in platelets from patients with end-stage renal failure using an AN69 membrane were significantly lower as compared with those in platelets before hemodialysis (51 +/- 18 vs. 93 +/- 39 fg/platelet, p < 0.05) as well as compared with those in platelets from patients using a polysulfone membrane (51 +/- 18 vs. 250 +/- 59 fg/platelet, p < 0.05).

Conclusions: It was found that hemofiltration by using an AN69 membrane has a direct effect on the intracellular amount of Ap(5)A and that changes of intracellular hydrophilic substances are dependent on the hemodialysis membrane used.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Acrylic Resins
  • Blood Platelets / metabolism*
  • Dinucleoside Phosphates / metabolism*
  • Female
  • Hemofiltration / instrumentation*
  • Hemofiltration / methods
  • Humans
  • Kidney Failure, Chronic / therapy*
  • Male
  • Membranes, Artificial*
  • Middle Aged
  • Polymers
  • Renal Dialysis / instrumentation*
  • Renal Dialysis / methods
  • Sulfones

Substances

  • Acrylic Resins
  • Dinucleoside Phosphates
  • Membranes, Artificial
  • Polymers
  • Sulfones
  • polyacrylonitrile
  • polysulfone P 1700
  • P(1),P(5)-di(adenosine-5'-)pentaphosphate