A modified catheter ablation technique was studied prospectively in 29 patients with atrioventricular (AV) nodal reentrant tachycardia. A His bundle electrode catheter was used for mapping and ablation. Cathodic electroshocks (100-250 J) were delivered from the distal two electrodes (connected in common) of the His bundle catheter to the site selected for ablation. The optimal ablation site recorded the earliest retrograde atrial depolarization, simultaneous or earlier than the QRS complex, with absence of a His bundle deflection during AV nodal reentrant tachycardia. One additional electrical shock was delivered if complete abolition of retrograde VA conduction persisted for more than 30 min and AV nodal reentrant tachycardia was not inducible during isoproterenol and/or atropine administration. With a cumulative energy of 323 +/- 27 J and a mean of 2.3 +/- 0.5 shocks interruption or impairment of retrograde nodal conduction was achieved. Antegrade conduction, although modified, was preserved in 27 patients, with persistence of complete AV block in 2 patients. Two of the 27 patients still need antiarrhythmic agents to control tachycardia, the other 25 patients were free of tachycardia within a mean follow-up period of 13 +/- 2 months (range 7 to 20 months). Twenty-three patients received late follow-up electrophysiological studies (3-6 months after the ablation procedures), and the AV nodal function curves were classified into 4 types. The majority of the patients (15/23) had loss of retrograde conduction. Among the 8 patients with prolongation of retrograde conduction, 4 patients still had antegrade dual AV nodal property but all without inducible tachycardia. In conclusion, preferential interruption or impairment of retrograde conduction was the major, but not the sole, mechanism of electrical cure of AV nodal reentrant tachycardia.