A rapid troponin I assay is not optimal for determination of troponin status and prediction of subsequent cardiac events at suspicion of unstable coronary syndromes

Int J Cardiol. 2004 Feb;93(2-3):113-20. doi: 10.1016/S0167-5273(03)00157-8.

Abstract

Background: Troponin is a specific marker of myocardial damage. For early prediction of coronary events in patients with suspicion of acute coronary syndromes the assay also needs to be highly sensitive.

Methods and results: A rapid troponin I assay was performed prior to inclusion in 4447 acute coronary syndrome patients in the GUSTO-IV trial. A quantitative troponin T analysis was later performed on blood samples obtained at randomization by a central laboratory. There was an agreement between the rapid troponin I assay and troponin T (< or =/>0.1 microg/l) in 3596 (80.9%) patients. A positive rapid troponin I was identifying any elevation of troponin T (>0.01 microg/l) in 1990 patients (90.4%) whereas a negative rapid troponin I was corresponding to negative troponin T (< or =0.01 microg/l) in only 1217 patients (54.2%). Patients with a positive versus negative rapid troponin I had an increased risk of death or myocardial infarction at 30 days (9.3 vs. 5.9%; odds ratio, O.R. 1.64; 95% confidence interval, 1.31-2.06). Troponin T elevation (>0.1 microg/l) provided a better (10.5 v. 4.9%, O.R. 2.26; C.I. 1.79-2.85) risk stratification. Regardless of a positive or a negative rapid troponin I, the troponin T result (>0.1 vs. < or =0.1 microg/l) stratified the patients into high and low risk of events at 30 days, (10.3 vs. 5.7%, P=0.002) and (11.5 vs. 4.8%, P<0.001), respectively.

Conclusion: In a population with non-ST elevation acute coronary syndrome a positive rapid troponin I assay is a specific indicator of troponin elevation and a predictor of early outcome. However, a negative rapid troponin I is not a reliable indicator of the absence of myocardial damage and does not indicate a low risk of subsequent cardiac events. A rapid troponin I assay was performed prior to inclusion in 4447 acute coronary syndrome patients in the GUSTO-IV trial and related to a centrally analyzed quantitative troponin T test. A positive rapid troponin I was well corresponding to any elevation of troponin T (>0.01 microg/l) and predicted an unfavorable outcome at 30 days. However, a negative rapid troponin I was corresponding to troponin T < or =0.01 microg/l in only half of the patients. Troponin T >0.1 microg/l vs. < or =0.1 microg/l provided a better risk stratification than the rapid troponin I result. For patients with troponin T elevation (>0.1 microg/l) the 30 day event rate was high regardless of the rapid troponin I result.

Publication types

  • Clinical Trial
  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Abciximab
  • Acute Disease
  • Aged
  • Antibodies, Monoclonal / therapeutic use
  • Anticoagulants / therapeutic use
  • Coronary Disease / blood
  • Coronary Disease / diagnosis*
  • Double-Blind Method
  • Female
  • Follow-Up Studies
  • Humans
  • Immunoglobulin Fab Fragments / therapeutic use
  • Male
  • Middle Aged
  • Platelet Glycoprotein GPIIb-IIIa Complex / antagonists & inhibitors
  • Predictive Value of Tests
  • Risk Assessment
  • Sensitivity and Specificity
  • Troponin I / blood*
  • Troponin T / blood

Substances

  • Antibodies, Monoclonal
  • Anticoagulants
  • Immunoglobulin Fab Fragments
  • Platelet Glycoprotein GPIIb-IIIa Complex
  • Troponin I
  • Troponin T
  • Abciximab