High-performance liquid chromatographic determination of vinblastine, 4-O-deacetylvinblastine and the potential metabolite 4-O-deacetylvinblastine-3-oic acid in biological fluids

J Chromatogr. 1991 Aug 16;553(1-2):47-53. doi: 10.1016/s0021-9673(01)88471-5.

Abstract

Procedures for the determination of vinblastine (VBL), 4-O-deacetylvinblastine (DVBL) and 4-O-deacetylvinblastine-3-oic acid (DVBLA) in biological samples using high-performance liquid chromatography (HPLC) combined with selective sample clean-up are presented. VBL and DVBL were determined in plasma and urine using ion-exchange normal-phase HPLC with fluorescence detection. The limit of detection was 1 microgram/l for both compounds using a 500-microliter sample. Successful chromatographic analyses of DVBLA were achieved by using a glass column packed with 5-microns Hypersil ODS and acetonitrile-0.05 M phosphate buffer (pH 2.7) (23:77, v/v). Positive identification was supported by the use of diode-array detection. The limit of detection (at 270 nm) was 10 micrograms/l using 1-ml samples.

MeSH terms

  • Adult
  • Aged
  • Chromatography, High Pressure Liquid
  • Humans
  • Male
  • Spectrometry, Fluorescence
  • Vinblastine / analogs & derivatives*
  • Vinblastine / blood
  • Vinblastine / metabolism*
  • Vinblastine / urine

Substances

  • 4-desacetylvinblastine
  • Vinblastine
  • 4-O-deacetylvinblastine-3-oic acid