Left ventricular systolic and diastolic dyssynchrony in asymptomatic hypertensive patients

J Am Soc Echocardiogr. 2009 Apr;22(4):337-42. doi: 10.1016/j.echo.2009.01.024. Epub 2009 Mar 9.

Abstract

Background: Diastolic and systolic dyssynchrony are common in patients with heart failure. However, the presence of dyssynchrony in asymptomatic patients with hypertension who are susceptible to the development of heart failure is not well understood. The aims of this study were (1) to evaluate the prevalence of systolic and diastolic dyssynchrony and (2) to identify the main determinants of left ventricular (LV) dyssynchrony in asymptomatic patients with hypertension.

Methods: One hundred ten patients with hypertension consecutively enrolled were compared with 55 age-matched and gender-matched normal control subjects. Comprehensive echocardiography was performed, including conventional and Doppler tissue imaging parameters. LV end-systolic wall stress was calculated using a hemodynamic and echocardiographic M-mode data set. For the assessment of LV dyssynchrony, both the standard deviation of the time from QRS onset to peak systolic velocity and the maximal difference of the time from QRS onset to peak systolic velocity from 6 basal segments at the apical views were used and were compared between the two groups.

Results: Both systolic and diastolic dyssynchrony indexes were significantly higher in patients with hypertension than in the normal controls (P < .001), with no significant correlation between the systolic and diastolic dyssynchrony indexes. The proportions of patients with hypertension who had LV systolic and diastolic dyssynchrony were 24% and 21%, respectively. Multivariate analysis showed that the E/E' ratio (P < .001) was independently associated with LV systolic dyssynchrony, whereas LV mass index (P = .001) and E/E' (P < .001) were major determinants of LV diastolic dyssynchrony.

Conclusions: LV systolic and diastolic dyssynchrony are not uncommon in asymptomatic patients with hypertension and are significantly associated with LV filling pressure. The determinants of LV systolic dyssynchrony are not the same as those of diastolic dyssynchrony, implying that different mechanisms are involved in the development of LV systolic and diastolic dyssynchrony in asymptomatic patients with hypertension.

MeSH terms

  • Algorithms
  • Diastole
  • Echocardiography, Doppler / methods*
  • Female
  • Humans
  • Hypertension / complications*
  • Hypertension / diagnostic imaging*
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Male
  • Middle Aged
  • Pattern Recognition, Automated / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Systole
  • Ventricular Dysfunction, Left / diagnostic imaging*
  • Ventricular Dysfunction, Left / etiology*