A bivariate measurement error model for nitrogen and potassium intakes to evaluate the performance of regression calibration in the European Prospective Investigation into Cancer and Nutrition study

Eur J Clin Nutr. 2009 Nov:63 Suppl 4:S179-87. doi: 10.1038/ejcn.2009.80.

Abstract

Objectives: Within the European Prospective Investigation into Cancer and Nutrition (EPIC) study, the performance of 24-h dietary recall (24-HDR) measurements as reference measurements in a linear regression calibration model is evaluated critically at the individual (within-centre) and aggregate (between-centre) levels by using unbiased estimates of urinary measurements of nitrogen and potassium intakes.

Methods: Between 1995 and 1999, 1072 study subjects (59% women) from 12 EPIC centres volunteered to collect 24-h urine samples. Log-transformed questionnaire, 24-HDR and urinary measurements of nitrogen and potassium intakes were analysed in a multivariate measurement error model to estimate the validity of coefficients and error correlations in self-reported dietary measurements. In parallel, correlations between means of 24-HDR and urinary measurements were computed. Linear regression calibration models were used to estimate the regression dilution (attenuation) factors.

Results: After adjustment for sex, centre, age, body mass index and height, the validity coefficients for 24-HDRs were 0.285 (95% confidence interval: 0.194, 0.367) and 0.371 (0.291, 0.446) for nitrogen and potassium intakes, respectively. The attenuation factors estimated in a linear regression calibration model were 0.368 (0.228, 0.508) for nitrogen and 0.500 (0.361, 0.639) for potassium intakes; only the former was different from the estimate obtained using urinary measurements in the measurement error model. The aggregate-level correlation coefficients between means of urinary and 24-HDR measurements were 0.838 (0.637, 0.932) and 0.756 (0.481, 0.895) for nitrogen and potassium intakes, respectively.

Conclusions: This study suggests that 24-HDRs can be used as reference measurements at the individual and aggregate levels for potassium intake, whereas, for nitrogen intake, good performance is observed for between-centre calibration, but some limitations are apparent at the individual level.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Adult
  • Aged
  • Calibration / standards*
  • Diet Records*
  • Diet Surveys
  • Diet*
  • Europa
  • Female
  • Humans
  • Linear Models
  • Logistic Models
  • Male
  • Micronutrients / administration & dosage
  • Micronutrients / urine
  • Middle Aged
  • Nitrogen / administration & dosage*
  • Nitrogen / urine
  • Potassium / administration & dosage*
  • Potassium / urine
  • Prospective Studies
  • Reference Values
  • Reproducibility of Results

Substances

  • Micronutrients
  • Nitrogen
  • Potassium