Purpose: To detect anti-CEACAM5 targeted superparamagnetic iron oxide (SPIO) particles in vitro on the cell surface by quantitative magnetic resonance (MR) imaging and to compare with flow cytometry.
Materials and methods: The monoclonal mouse antibody T84.1 and an appropriate IgG isotype antibody were conjugated to dextran-coated SPIO particles. HT29 cells expressing carcinoembryonic antigen (CEACAM5) were treated with antibody-conjugated SPIO particles. Purified cell samples were examined on a 3.0-T MR scanner using a multi-echo spin-echo sequence for MR relaxometry. Aliquots of the cell samples were further treated with a fluorescein isothiocyanate (FITC) anti-dextran antibody and an Alexa Fluor 488 anti-mouse antibody for the corresponding flow cytometry.
Results: MR relaxometry revealed a dose-dependent binding of T84.1-conjugated SPIO particles with a positive correlation between R(2) relaxation rate of cell samples and SPIO particle concentration during incubation (r=0.993, P<.01). Positive correlations were also observed between R(2) relaxation rate and flow cytometry (geometric mean) with both fluorescent antibodies (r=0.972 and r=0.953, both P<.01), respectively.
Conclusion: The study revealed the feasibility of quantitative MR imaging of targeted SPIO particles on the cell surface comparable to flow cytometry.
2010 Elsevier Inc. All rights reserved.