Background: Salivary cortisol is increasingly used to assess patients with suspected hypo- and hypercortisolism. This study established disease-specific reference ranges for an automated electrochemiluminescence immunoassay (ECLIA).
Methods: Unstimulated saliva from 62 patients with hypothalamic-pituitary disease was collected at 0800 h. A peak serum cortisol level below 500 nmol/l during the insulin tolerance test (ITT) was used to identify hypocortisolism. Receiver-operating characteristic (ROC) analysis allowed establishment of lower and upper cutoffs with at least 95% specificity for adrenal insufficiency and adrenal sufficiency. Saliva from 40 patients with confirmed hypercortisolism, 45 patients with various adrenal masses, and 115 healthy subjects was sampled at 2300 h and after low-dose dexamethasone suppression at 0800 h . ROC analysis was used to calculate thresholds with at least 95% sensitivity for hypercortisolism. Salivary cortisol was measured with an automated ECLIA.
Results: When screening for secondary adrenal insufficiency, a lower cutoff of 3.2 nmol/l and an upper cutoff of 13.2 nmol/l for unstimulated salivary cortisol allowed a highly specific diagnosis (i.e. similar to the ITT result) in 26% of patients. For identification of hypercortisolism, cutoffs of 6.1 nmol/l (sensitivity 95%, specificity 91%, area under the curve (AUC) 0.97) and 2.0 nmol/l (sensitivity 97%, specificity 86%, AUC 0.97) were established for salivary cortisol at 2300 h and for dexamethasone-suppressed salivary cortisol at 0800 h.
Conclusions: The newly established thresholds facilitated initial screening for secondary adrenal insufficiency and allowed excellent identification of hypercortisolism. Measurement by an automated immunoassay will allow broader use of salivary cortisol as a diagnostic tool.