Survival of patients receiving a primary prevention implantable cardioverter-defibrillator in clinical practice vs clinical trials

JAMA. 2013 Jan 2;309(1):55-62. doi: 10.1001/jama.2012.157182.

Abstract

Importance: Randomized clinical trials have shown that implantable cardioverter-defibrillator (ICD) therapy saves lives. Whether the survival of patients who received an ICD in primary prevention clinical trials differs from that of trial-eligible patients receiving a primary prevention ICD in clinical practice is unknown.

Objective: To determine whether trial-eligible patients who received a primary prevention ICD as documented in a large national registry have a survival rate that differs from the survival rate of similar patients who received an ICD in the 2 largest primary prevention clinical trials, MADIT-II (n = 742) and SCD-HeFT (n = 829).

Design, setting, and patients: Retrospective analysis of data for patients enrolled in the National Cardiovascular Data Registry ICD Registry between January 1, 2006, and December 31, 2007, meeting the MADIT-II criteria (2464 propensity score-matched patients) or the SCD-HeFT criteria (3352 propensity score-matched patients). Mortality data for the registry patients were collected through December 31, 2009.

Main outcome measures: Cox proportional hazards models were used to compare mortality from any cause.

Results: The median follow-up time in MADIT-II, SCD-HeFT, and the ICD Registry was 19.5, 46.1, and 35.2 months, respectively. Compared with patients enrolled in the clinical trials, patients in the ICD Registry were significantly older and had a higher burden of comorbidities. In the matched cohorts, there was no significant difference in survival between MADIT-II-like patients in the registry and MADIT-II patients randomized to receive an ICD (2-year mortality rates: 13.9% and 15.6%, respectively; adjusted ICD Registry vs trial hazard ratio, 1.06; 95% CI, 0.85-1.31; P = .62). Likewise, the survival among SCD-HeFT-like patients in the registry was not significantly different from survival among patients randomized to receive ICD therapy in SCD-HeFT (3-year mortality rates: 17.3% and 17.4%, respectively; adjusted registry vs trial hazard ratio, 1.16; 95% CI, 0.97-1.38; P = .11).

Conclusions and relevance: There was no significant difference in survival between clinical trial patients randomized to receive an ICD and a similar group of clinical registry patients who received a primary prevention ICD. Our findings support the continued use of primary prevention ICDs in similar patients seen in clinical practice.

Trial registration: clinicaltrials.gov Identifier: NCT00000609.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Age Factors
  • Aged
  • Cause of Death
  • Comorbidity
  • Death, Sudden, Cardiac / prevention & control
  • Defibrillators, Implantable / statistics & numerical data*
  • Eligibility Determination
  • Female
  • Heart Failure / mortality*
  • Heart Failure / therapy*
  • Humans
  • Male
  • Middle Aged
  • Primary Prevention
  • Propensity Score
  • Randomized Controlled Trials as Topic
  • Registries / statistics & numerical data
  • Retrospective Studies
  • Survival Analysis

Associated data

  • ClinicalTrials.gov/NCT00000609