Transcatheter aortic valve-in-valve (VIV) implantation in high-risk patients with degenerative surgical bioprosthetic aortic valves is a novel application of transcatheter aortic valve replacement technology. Although transcatheter aortic VIV procedure is clinically effective in most patients, it is a more demanding procedure in terms of the technical aspects of procedural planning. VIV carries a higher risk of coronary occlusion which is associated with a higher rate of in-hospital mortality. We hereby report a technique of pre-emptive left main (LM) protection, by positioning a coronary stent in the proximal left anterior descending artery prior to VIV implantation. The patient treated was considered to be at an increased risk of LM occlusion as a result of the procedure. The technique was performed in anticipation of emergent bailout stenting of the LM. As predicted, the LM occluded during the procedure and LM protection facilitated the safe and effective treatment of an otherwise life-threatening procedure.
Keywords: left main coronary disease; percutaneous coronary intervention; valvular heart disease.