Relationship between pre-implant ejection fraction and outcome after cardiac resynchronization therapy in symptomatic patients

Acta Cardiol. 2014 Aug;69(4):424-32. doi: 10.1080/ac.69.4.3036659.

Abstract

Background: Left-ventricular ejection fraction (LVEF) is regarded as a strong predictor for morbidity and mortality in heart failure patients. The aim of the analysis was to assess the relationship between pre-implant LVEF and outcome of patients with advanced heart failure who received cardiac resynchronization therapy (CRT).

Methods: We analysed the two-year follow-up of 366 patients who had been enrolled in the MASCOT study which included NYHA class III/IV patients with a class I CRT indication. Pre-implant LVEF was stratified by tertile.

Results: The boundaries for pre-implant LVEF were < 22% (n = 128; 18.2 +/- 3.1%; T(low)), 22% to 28% (n = 121; 25.4 +/- 1.4%; T(middle)) and > 28% (n = 117; 32.6 +/- 3.9%; T(high)) for each tertile.Two-year post-implant LVEF was 32.0 +/- 11.5% (T(low)), 33.7 +/- 10.8% (T(middle)) and 36.4 +/- 9.9% (T(high)). T(Iow) had a greater increase between pre- and post-implant LVEF compared to T(middle) (P = 0.03) and T(high) (P = 0.0001). NYHA class improved similarly among the three groups as well as the quality of life score. No significant differences were detected between the three groups for all-cause mortality, cardiac death, all-cause hospitalization, and hospitalization due to worsening heart failure.

Conclusions: Symptomatic heart failure patients with a wide QRS complex and a severe impaired LV function had a better improvement of their pre-implant LVEF than patients with a more preserved LVEF. This may be one reason that in these patient groups long-term morbidity and mortality were not related to their pre-implant LVEF. Pre-implant LVEF was in symptomatic CRT patients not predictive for their long-term cardiovascular morbidity and mortality.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cardiac Resynchronization Therapy* / methods
  • Defibrillators, Implantable*
  • Female
  • Follow-Up Studies
  • Frankreich
  • Deutschland
  • Griechenland
  • Heart Failure / diagnostic imaging
  • Heart Failure / mortality
  • Heart Failure / physiopathology
  • Heart Failure / therapy*
  • Humans
  • Italien
  • Male
  • Middle Aged
  • Pacemaker, Artificial*
  • Single-Blind Method
  • Stroke Volume*
  • Treatment Outcome
  • Ultrasonography