Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation

Am J Cardiol. 2015 Nov 15;116(10):1566-73. doi: 10.1016/j.amjcard.2015.08.021. Epub 2015 Aug 31.

Abstract

The current transcatheter aortic valve implantation (TAVI) devices have been designed to fit Caucasian and Latin American aortic root anatomies. We evaluated the racial differences in aortic root anatomy and calcium distribution in patients with aortic stenosis who underwent TAVI. We conducted a multicenter study of 4 centers in Asia and Europe, which includes consecutive patients who underwent TAVI with preprocedural multidetector computed tomography. Quantitative assessment of aortic root dimensions, calcium volume for leaflet, and left ventricular outflow tract were retrospectively performed in a centralized core laboratory. A total of 308 patients (Asian group, n = 202; Caucasian group, n = 106) were analyzed. Compared to Caucasian group, Asian group had smaller annulus area (406.3 ± 69.8 vs 430.0 ± 76.8 mm(2); p = 0.007) and left coronary cusp diameter (30.2 ± 3.2 vs 31.1 ± 3.4 mm; p = 0.02) and lower height of left coronary artery ostia (12.0 ± 2.5 vs 13.4 ± 3.4 mm; p <0.001). Of baseline anatomic characteristics, body height showed the highest correlation with annulus area (Pearson correlation r = 0.64; p <0.001). Co-existence of lower height of left coronary artery ostia (<12 mm) and small diameter of left coronary cusp (<30 mm) were more frequent in Asian group compared with Caucasian group (35.6% vs 20.8%; p = 0.02). In contrast, there were no differences in calcium volumes of leaflet (367.2 ± 322.5 vs 359.1 ± 325.7 mm(3); p = 0.84) and left ventricular outflow tract (8.9 ± 23.4 vs 10.1 ± 23.8 mm(3); p = 0.66) between 2 groups. In conclusion, judicious consideration will be required to perform TAVI for short patients with lower height of left coronary artery ostia and small sinus of Valsalva.

Publication types

  • Comparative Study
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged, 80 and over
  • Aorta, Thoracic / diagnostic imaging*
  • Aortic Valve / diagnostic imaging*
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / etiology
  • Aortic Valve Stenosis / surgery*
  • Asia / epidemiology
  • Calcinosis / complications*
  • Calcinosis / diagnostic imaging
  • Calcinosis / epidemiology
  • Cardiac Catheterization
  • Europe / epidemiology
  • Female
  • Humans
  • Incidence
  • Male
  • Multidetector Computed Tomography / methods*
  • Transcatheter Aortic Valve Replacement*