Introduction: Inverse-planned intensity modulated radiation therapy (IP-IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter-planner variability and lower doses to organs at risk (OAR). We therefore conducted a pilot study of previously treated intact breast patients to compare the current forward-planned 'field-in-field' technique (FP-IMRT) with an IP-IMRT alternative.
Methods: The IP-IMRT plans of 20 patients were generated from a template created for the planning system. All patients were prescribed adjuvant whole breast radiotherapy using a hypofractionated regimen of 40.05 Gy in 15 fractions over 3 weeks. Plans were assessed based on visual inspection of coverage as well as statistical analysis and compared to the clinically acceptable FP-IMRT plans. Patients were planned retrospectively in Monaco 3.2® using a laterality-specific, tangential planning template. Minor adjustments were made as necessary to meet the planning criteria in the protocol. Dose coverage, maximums, homogeneity indices and doses to OAR were recorded.
Results: The IP-IMRT plans provided more consistent coverage (38.18 Gy vs. 36.08 Gy of D95; P = 0.005), a comparable though higher average maximum (D2 = 42.52 Gy vs. 42.08 Gy; P = 0.0001), more homogeneous plans (homogeneity index = 0.908 vs. 0.861; P = 0.01) and somewhat lower V20 heart and lung doses (0.11% vs. 0.89% for heart; 5.4% vs. 7.52% for lung) than FP-IMRT (P > 0.05).
Conclusion: Clinically acceptable plans have been generated using the IP-IMRT templates in Monaco. Improvements in consistency and quality were seen when compared to the FP-IMRT plans. The template-based process is an efficient method to inversely plan IMRT for breast patients.
Keywords: Breast cancer; intensity modulated radiotherapy; radiotherapy; radiotherapy planning.
© 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.