Performance of Xpert MTB/RIF, Xpert Ultra, and Abbott RealTi m e MTB for Diagnosis of Pulmonary Tuberculosis in a High-HIV-Burden Setting

J Clin Microbiol. 2018 Nov 27;56(12):e00560-18. doi: 10.1128/JCM.00560-18. Print 2018 Dec.

Abstract

More sensitive tests are needed for the diagnosis of smear-negative and HIV-associated tuberculosis. This study compares the sensitivities and specificities of three molecular tests, namely, the Xpert MTB/RIF test, the Xpert Ultra (Ultra), and RealTime MTB (RT-MTB), in a high HIV prevalence setting. Symptomatic adults were recruited from three outpatient sites, and each provided 4 sputum specimens. The diagnostic performance of Xpert MTB/RIF, Ultra, and RT-MTB was evaluated, with culture as a reference standard. HIV infection occurred in 62% of patients, with a median CD4 count of 220 cells/µl. The Ultra test had the highest sensitivity of 89.3% (95% confidence interval [CI], 78.1 to 96) compared to those of the Xpert MTB/RIF at 82.1% (95% CI, 69.6 to 91.1; P = 0.12) and RT-MTB at 78.6% (95% CI, 65.6 to 88.4; P = 0.68). The specificity was highest with the Xpert MTB/RIF at 100% (95% CI, 98 to 100), followed by RealTime MTB at 96.7% (95% CI, 92.9 to 98.8; P = 0.03) and the Ultra at 95.6% (95% CI, 91.5 to 98.1; P = 0.08). In patients with smear-negative disease, the Ultra was more sensitive than the Xpert MTB/RIF (64.7% [95% CI, 38.3 to 85.8] versus 41.2% [95% CI, 18.4 to 67.1], respectively; P = 0.12), and RT-MTB performed equally to Xpert MTB/RIF. In a comparison of the Ultra and RT-MTB on the same sputum specimen pellets, the Ultra was more sensitive than RT-MTB in the overall cohort (88.9% [95% CI, 77.4 to 95.8] versus 77.8% [95% CI, 64.4 to 88], respectively; P = 0.03) and among people with HIV (87.5% [95% CI, 71 to 96.5] versus 68.6% [95% CI, 50 to 83.9], respectively; P = 0.03). Although these results did not reach statistical significance, they suggest that the Ultra is more sensitive than the Xpert MTB/RIF and RT-MTB, most prominently in smear-negative disease. This was accompanied by a loss of specificity.

Keywords: Abbott RealTime MTB; South Africa; Xpert MTB/RIF; Xpert Ultra; molecular diagnostics; tuberculosis.

Publication types

  • Evaluation Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • AIDS-Related Opportunistic Infections / blood
  • AIDS-Related Opportunistic Infections / diagnosis*
  • AIDS-Related Opportunistic Infections / epidemiology
  • Adolescent
  • Adult
  • Aged
  • CD4 Lymphocyte Count
  • Diagnostic Tests, Routine / standards*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Molecular Diagnostic Techniques / methods*
  • Molecular Diagnostic Techniques / standards*
  • Mycobacterium tuberculosis / isolation & purification*
  • Reference Standards
  • Sensitivity and Specificity
  • South Africa / epidemiology
  • Sputum / microbiology
  • Tuberculosis, Pulmonary / blood
  • Tuberculosis, Pulmonary / diagnosis*
  • Tuberculosis, Pulmonary / epidemiology
  • Young Adult