Prostate Cancer Risk Stratification in Men With a Clinical Suspicion of Prostate Cancer Using a Unique Biparametric MRI and Expression of 11 Genes in Apparently Benign Tissue: Evaluation Using Machine-Learning Techniques

J Magn Reson Imaging. 2020 May;51(5):1540-1553. doi: 10.1002/jmri.26945. Epub 2019 Oct 6.

Abstract

Background: Accurate risk stratification of men with a clinical suspicion of prostate cancer (cSPCa) remains challenging despite the increasing use of MRI.

Purpose: To evaluate the diagnostic accuracy of a unique biparametric MRI protocol (IMPROD bpMRI) combined with clinical and molecular markers in men with cSPCa.

Study type: Prospective single-institutional clinical trial (NCT01864135).

Subjects: Eighty men with cSPCa.

Field strength/sequence: 3T, surface array coils. Two T2 -weighted and three diffusion-weighted imaging (DWI) acquisitions: 1) b-values 0, 100, 200, 300, 500 s/mm2 ; 2) b-values 0,1500 s/mm2 ; 3) b-values 0, 2000 s/mm2 .

Assessment: IMPROD bpMRI examinations were qualitatively (IMPROD bpMRI Likert score) and quantitatively (DWI-based Gleason grade score) prospectively reported. Men with IMPROD bpMRI Likert 3-5 had two targeted biopsies followed by 12-core systematic biopsies (SB); those with IMPROD bpMRI Likert 1-2 had only SB. Additionally, 2-core from normal-appearing prostate areas were obtained for the mRNA expression of ACSM1, AMACR, CACNA1D, DLX1, PCA3, PLA2G7, RHOU, SPINK1, SPON2, TMPRSS2-ERG, and TDRD1 measured by quantitative reverse-transcription polymerase chain reaction.

Statistical tests: Univariate and multivariate analysis using regularized least-squares, feature selection and tournament leave-pair-out cross-validation (TLPOCV), as well as 10 random splits of the data in training-testing sets, were used to evaluate the mRNA, clinical and IMPROD bpMRI parameters in detecting clinically significant prostate cancer (SPCa) defined as Gleason score ≥ 3 + 4. The evaluation metric was the area under the curve (AUC).

Results: IMPROD bpMRI Likert demonstrated the highest TLPOCV AUC of 0.92. The tested clinical variables had AUC 0.56-0.73, while the mRNA and additional IMPROD bpMRI parameters had AUC 0.50-0.67 and 0.65-0.89 respectively. The combination of clinical and mRNA biomarkers produced TLPOCV AUC of 0.87, the highest TLPOCV performance without including IMPROD bpMRI Likert.

Data conclusion: The qualitative IMPROD bpMRI Likert score demonstrated the highest accuracy for SPCa detection compared with the tested clinical variables and mRNA biomarkers.

Level of evidence: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1540-1553.

Keywords: PSA; biomarker; biparametric MRI; cross-validation; diffusion weighted imaging; field cancerization effect; gene expression; permutation test; prostate cancer; prostate cancer screening; qRT-PCR; single-institutional trial.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Maschinelles Lernen
  • Magnetic Resonance Imaging
  • Male
  • Prospective Studies
  • Prostatic Neoplasms* / diagnostic imaging
  • Prostatic Neoplasms* / genetics
  • Risk Assessment
  • Trypsin Inhibitor, Kazal Pancreatic

Substances

  • SPINK1 protein, human
  • Trypsin Inhibitor, Kazal Pancreatic

Associated data

  • ClinicalTrials.gov/NCT01864135