Does prior mediastinal lymph node aspiration contribute to false-positive positron emission tomography-computed tomography?

ERJ Open Res. 2020 Oct 5;6(4):00103-2020. doi: 10.1183/23120541.00103-2020. eCollection 2020 Oct.

Abstract

Background: Proper staging of the mediastinum is an essential component of lung cancer evaluation. Positron emission tomography-computed tomography (PETCT) and endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) are an integral part of this process. False-positive PETCT results can occur following surgical procedures but has not been demonstrated following EBUS-TBNA. We aimed to determine whether false-positive PETCT rates increase when EBUS-TBNA is performed prior to PETCT.

Study design and methods: A retrospective review was carried out of clinical cases that underwent both PETCT and EBUS-TBNA within 30 days for the suspected malignancy. The impact of test sequence on the PETCT false-positive rate (FPR) was determined using Generalised Estimating Equation logistic regression analysis.

Results: A total of 675 lymph node stations were sampled and imaged on PETCT. Overall, 332 (49.2%) nodes were sampled by EBUS-TBNA before PETCT, and 343 (50.8%) afterwards, with the interval between EBUS and subsequent PETCT being a mean±sd of 11.6±6.8 days (range 1-29). The FPR on qualitative PETCT for the EBUS first group was 41 (23.2%) out of 164, and for PETCT first it was 57 (29.0%) out of 193 for a difference of 5.8% (95% CI -3.4-14.7, p=0.22). In the regression model, EBUS as the first test was associated with a lower FPR when using the clinical PETCT interpretation.

Interpretation: The performance of EBUS-TBNA sampling did not influence the FPR of PETCT when bronchoscopy took place in the 30 days prior to testing. Test sequence should be selected based on other clinical considerations.