Abstract

Objectives: The aim of this study was to evaluate clinical characteristics, mechanisms of failure, and outcomes of transcatheter aortic valve replacement (TAVR) explantation.

Background: Surgical explantation following TAVR may be required for structural valve degeneration, paravalvular leak, infection, or other reasons. However, in-depth data on indications and outcomes are lacking.

Methods: Data from a multicenter, international registry (EXPLANT-TAVR) of patients who underwent TAVR explantation were reviewed retrospectively. Explantations performed during the same admission as initial TAVR were excluded. Clinical and echocardiographic outcomes were evaluated. Median follow-up duration was 6.7 months (interquartile range [IQR]: 1.0-18.8 months) after TAVR explantation and was 97.7% complete at 30 days and 86.1% complete at 1 year.

Results: From November 2009 to September 2020, 269 patients across 42 centers with a mean age of 72.7 ± 10.4 years underwent TAVR explantation. About one quarter (25.9%) were deemed low surgical risk at index TAVR, and median Society of Thoracic Surgeons risk at TAVR explantation was 5.6% (IQR: 3.2%-9.6%). The median time to explantation was 11.5 months (IQR: 4.0-32.4 months). Balloon-expandable and self-expanding or mechanically expandable valves accounted for 50.9% and 49.1%, respectively. Indications for explantation included endocarditis (43.1%), structural valve degeneration (20.1%), paravalvular leak (18.2%), and prosthesis-patient mismatch (10.8%). Redo TAVR was not feasible because of unfavorable anatomy in 26.8% of patients. Urgent or emergency cases were performed in 53.1% of patients, aortic root replacement in 13.4%, and 54.6% had concomitant cardiac procedures. Overall survival at last follow-up was 76.1%. In-hospital, 30-day, and 1-year mortality rates were 11.9%, 13.1%, and 28.5%, respectively, and stroke rates were 5.9%, 8.6%, and 18.7%, respectively.

Conclusions: The EXPLANT-TAVR registry reveals that surgical risks associated with TAVR explantation are not negligible and should be taken into consideration in the lifetime management of aortic stenosis.

Keywords: TAVR explantation; TAVR failure; surgical aortic valve replacement; transcatheter aortic valve replacement.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Prosthesis*
  • Humans
  • Middle Aged
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome