Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imaging

Eur Heart J Cardiovasc Imaging. 2022 Nov 17;23(12):1584-1595. doi: 10.1093/ehjci/jeac191.

Abstract

Aims: Whether hypoattenuated leaflet thickening (HALT) following transcatheter aortic valve implantation (TAVI) carries a risk of subclinical brain injury (SBI) is unknown. We investigated whether HALT is associated with SBI detected on magnetic resonance imaging (MRI), and whether post-TAVI SBI impacts the patients' cognition and outcome.

Methods and results: We prospectively enrolled 153 patients (age: 78.1 ± 6.3 years; female 44%) who underwent TAVI. Brain MRI was performed shortly post-TAVI and 6 months later to assess the occurrence of acute silent cerebral ischaemic lesions (SCIL) and chronic white matter hyperintensities (WMH). HALT was screened by cardiac computed tomography (CT) angiography (CTA) 6 months post-TAVI. Neurocognitive evaluation was performed before, shortly after and 6 months following TAVI. At 6 months, 115 patients had diagnostic CTA and 10 had HALT. HALT status, baseline, and follow-up MRIs were available in 91 cases. At 6 months, new SCIL was evident in 16%, new WMH in 66%. New WMH was more frequent (100 vs. 62%; P = 0.047) with higher median volume (319 vs. 50 mm3; P = 0.039) among HALT-patients. In uni- and multivariate analysis, HALT was associated with new WMH volume (beta: 0.72; 95%CI: 0.2-1.39; P = 0.009). The patients' cognitive trajectory from pre-TAVI to 6 months showed significant association with the 6-month SCIL volume (beta: -4.69; 95%CI: -9.13 to 0.27; P = 0.038), but was not related to the presence or volume of new WMH. During a 3.1-year follow-up, neither HALT [hazard ratio (HR): 0.86; 95%CI: 0.202-3.687; P = 0.84], nor the related WMH burden (HR: 1.09; 95%CI: 0.701-1.680; P = 0.71) was related with increased mortality.

Conclusions: At 6 months post-TAVI, HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up (NCT02826200).

Keywords: HALT (hypoattenuated leaflet thickening); TAVI (transcatheter aortic valve implantation); WMH (white matter hyperintensities); brain MRI (magnetic resonance imaging); cognition.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / etiology
  • Aortic Valve Stenosis* / surgery
  • Brain
  • Brain Injuries* / etiology
  • Female
  • Heart Valve Prosthesis*
  • Humans
  • Magnetic Resonance Imaging
  • Risk Factors
  • Thrombosis* / etiology
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT02826200