Background: Urinary incontinence (UI) is a common worldwide rising health issue among women with a prevalence of 5 to 70%. Stress urinary incontinence (SUI) is the most common subtype of UI. There are different treatments for UI, including AUS (artificial urinary sphincter) implantation, as one of the surgical options for treating SUI. The aim of this study was to determine the complication rate of AUS, exclusively in female patients with SUI, which resulted from ISD (intrinsic sphincter deficiency). We also compared the complication rate between minimally invasive (laparoscopic or robotic surgery) and open approaches.
Methods: Scopus, PubMed, Web of Science, Embase, and Google Scholar were searched for studies regarding complications in AUS implantation surgery, from the beginning of the project to March 2022. After screening and reviewing of full text, the general characteristics of the study and study population including follow-up time, type of surgery, and the number of complications that occurred such as necrosis, atrophy, erosion, infection, mechanical failure, revision, and leak, were extracted.
Results: We found that atrophy occurred in 1 of 188 (0.53%) patients treated with minimally invasive surgery and in 1 of 669 (0.15%) patients treated with open surgery. None of the 17 included studies reported the occurrence of necrosis in the patients under study. Erosion occurred in 9 of 188 (4.78%) patients treated with minimally invasive surgery and in 41 of 669 (6.12%) patients treated with open surgery. Infection occurred in 12 of 188 (6.38%) patients treated with minimally invasive surgery and in 22 of 669 (3.2%) patients treated with open surgery. The mechanical failure occurred in 1 of 188 (0.53%) patients treated with minimally invasive surgery and in 55 of 669 (8.22%) patients treated with open surgery. Reconstructive surgery occurred in 7 of 188 (3.72%) patients treated with minimally invasive surgery and in 95 of 669 (14.2%) patients treated with open surgery. Leaks occurred in 4 of 188 (2.12%) patients treated with minimally invasive surgery and in 6 of 669 (0.89%) patients treated with open surgery. The type of surgery was associated with a statistically significant increase in mechanical failure (p-value = 0.067) and infection (p-value = 0.021), and reconstructive surgery (p-value = 0.049). Out of the 857 participats in the study,469 were studied for less than five years and 388 were studied for more than five years.21 of 469 (4.4%) (p-value = 0.08) patients and 81 of 388 (20.8%) (p-value = 0.001) patients required reconstructive surgery. Erosion occurred in 23 of 469 (4.9%) (p-value = 0.01)patients with following time less than five years and in 27 of 388 (6.9%) (p-value = 0.001) patients with following time more than five years.
Conclusion: The use of artificial urinary sphincters in the treatment of UI causes complications such as atrophy, erosion, and infection; the amount of which is influenced by the surgical method and the duration of using the artificial urinary sphincter. It seems that the use of new surgical methods, such as laparoscopic surgery, is useful in reducing the incidence of complications.
Keywords: Artificial urinary sphincter; Complete incontinence; Complication; Internal sphincter; Stress incontinence.
© 2023. The Author(s).