Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum

JACC Case Rep. 2023 May 22:16:101888. doi: 10.1016/j.jaccas.2023.101888. eCollection 2023 Jun 21.

Abstract

We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.).

Keywords: atrioventricular conduction axis; computed tomography; membranous septum; transcatheter aortic valve replacement; virtual basal ring.

Publication types

  • Case Reports