Post-ligation cardiac syndrome after surgical versus transcatheter closure of patent ductus arteriosus in low body weight premature infants: a multicenter retrospective cohort study

Eur J Pediatr. 2024 May;183(5):2193-2201. doi: 10.1007/s00431-024-05481-y. Epub 2024 Feb 21.

Abstract

Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence. Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.

Keywords: Patent ductus arteriosus; Post-ligation cardiac syndrome; Prematurity; Surgical ligation; Transcatheter closure.

Publication types

  • Multicenter Study
  • Comparative Study

MeSH terms

  • Cardiac Catheterization* / adverse effects
  • Cardiac Catheterization* / methods
  • Cardiac Surgical Procedures / adverse effects
  • Cardiac Surgical Procedures / methods
  • Ductus Arteriosus, Patent* / surgery
  • Female
  • Humans
  • Incidence
  • Infant, Low Birth Weight
  • Infant, Newborn
  • Infant, Premature*
  • Infant, Premature, Diseases / epidemiology
  • Infant, Premature, Diseases / etiology
  • Infant, Premature, Diseases / surgery
  • Infant, Premature, Diseases / therapy
  • Ligation / adverse effects
  • Ligation / methods
  • Male
  • Postoperative Complications* / epidemiology
  • Postoperative Complications* / etiology
  • Propensity Score
  • Retrospective Studies
  • Risk Factors
  • Septal Occluder Device
  • Syndrome