The reproducibility of manual RV/LV ratio measurement on CT pulmonary angiography

BJR Open. 2022 Nov 28;4(1):20220041. doi: 10.1259/bjro.20220041. eCollection 2022.

Abstract

Objectives: Right ventricular (RV) dysfunction carries elevated risk in acute pulmonary embolism (PE). An increased ratio between the size of the right and left ventricles (RV/LV ratio) is a biomarker of RV dysfunction. This study evaluated the reproducibility of RV/LV ratio measurement on CT pulmonary angiography (CTPA).

Methods: 20 inpatient CTPA scans performed to assess for acute PE were retrospectively identified from a tertiary UK centre. Each scan was evaluated by 14 radiologists who provided a qualitative overall opinion on the presence of RV dysfunction and measured the RV/LV ratio. Using a threshold of 1.0, the RV/LV ratio measurements were classified as positive (≥1.0) or negative (<1.0) for RV dysfunction. Interobserver agreement was quantified using the Fleiss κ and intraclass correlation coefficient (ICC).

Results: Qualitative opinion of RV dysfunction showed weak agreement (κ = 0.42, 95% CI 0.37-0.46). The mean RV/LV ratio measurement for all cases was 1.28 ± 0.68 with significant variation between reporters (p < 0.001). Although agreement for RV/LV measurement was good (ICC = 0.83, 95% CI 0.73-0.91), categorisation of RV dysfunction according to RV/LV ratio measurements showed weak agreement (κ = 0.46, 95% CI 0.41-0.50).

Conclusion: Both qualitative opinion and quantitative manual RV/LV ratio measurement show poor agreement for identifying RV dysfunction on CTPA.

Advances in knowledge: Caution should be exerted if using manual RV/LV ratio measurements to inform clinical risk stratification and management decisions.