Objectives: To evaluate the association of standardized prenatal imaging parameters and immediate neonatal variables with mortality prior to discharge in infants with isolated left congenital diaphragmatic hernia (LCDH), and to compare the performance of ultrasound- and magnetic resonance imaging (MRI)-based severity grading for the prediction of neonatal mortality.
Methods: This was a retrospective study of infants with prenatally diagnosed isolated LCDH referred to a single tertiary center between 2008 and 2020. Fetuses with right or bilateral congenital diaphragmatic hernia, additional major structural anomaly or known genetic condition, as well as cases that underwent fetal intervention or declined postnatal intervention, were excluded. Ultrasound and MRI images were reviewed retrospectively. Univariable and multivariable analyses were performed, incorporating prenatal and immediate neonatal factors to analyze the association with neonatal mortality prior to discharge, and a prediction calculator was generated. The performance of ultrasound and that of MRI for the prediction of neonatal mortality were compared.
Results: Of 253 pregnancies with fetal CDH, 104 met the inclusion criteria, of whom 77 (74%) neonates survived to discharge. Seventy-five fetuses underwent both prenatal ultrasound and MRI. On multivariable analysis, observed/expected (o/e) lung-to-head ratio and o/e total fetal lung volume were associated independently with neonatal death (adjusted odds ratio, 0.89 (95% CI, 0.83-0.95) and 0.90 (95% CI, 0.84-0.97), respectively), whereas liver position was not. There was no significant difference in predictive performance between using ultrasound and MRI together (area under the receiver-operating-characteristics curve (AUC), 0.85 (95% CI, 0.76-0.93)) compared with using ultrasound alone (AUC, 0.81 (95% CI, 0.72-0.90); P = 0.19). The addition of neonatal parameters (gestational age at birth and small-for-gestational age) did not improve model performance (AUC, 0.87 (95% CI, 0.80-0.95)) compared with the combined ultrasound and MRI model (P = 0.22). There was poor agreement between severity assessment on ultrasound and MRI (Cohen's κ, 0.19). Most discrepancies were seen among cases deemed to be non-severe on ultrasound and severe on MRI, and outcomes were more consistent with MRI-based prognostication.
Conclusions: In fetuses with prenatally diagnosed isolated LCDH, mortality prediction using standardized ultrasound and MRI measurements performed reasonably well. In cases classified as non-severe on ultrasound, MRI is recommended, as it may provide more accurate prognostication and assist in the determination of candidacy for fetal intervention. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Keywords: CDH; MRI; congenital diaphragmatic hernia; magnetic resonance imaging; neonatal mortality; ultrasound.
© 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.