Rawlbolt: Shield Anchor Loose Bolt
Rawlbolt: Shield Anchor Loose Bolt
Product Information
Sw Dw
DESCRIPTION Worlds most popular expanding shield anchor. Easy to use with good load carrying capacity. Ideal general purpose anchor bolt with excellent tolerance to variation in hole size. The collapsible ferrule ensures positive clamping force is transmitted to the fixture. SUITABLE FOR USE IN: Concrete Brickwork TYPICAL APPLICATIONS e Roller shutter doors Stone. e Fire doors e Steelwork e Security grills e Machinery e Pipework/duct work supports.
ho
FEATURES 1. Bolt lengths suitable for fixture thickness up to 150mm. 2. Ferrule marked with hole diameter for correct installation. 3. Pressed steel segments ensure consistent dimensional accuracy. 4. Optimum taper nut angle for maximum expansion in all substrates. 5. Shield available seperately.
REFERENCE
BOLT HEAD BOLT WASHER SHIELD DIAMETER LENGTH DIAMETER LENGTH (mm) (mm) (mm) (mm) (AF) (s) (l) (Dw) (S )
w
EFFECTIVE MINIMUM EMBEDMENT SUBSTRATE DEPTH THICKNESS (mm) (mm) (hef) (hmin)
PRODUCT CODE
NEW CODE
(Tinst)
(Tinst)
M6 10L M6 25L M6 40L M8 10L M8 25L M8 40L M10 10L M10 25L M10 50L M10 75L M12 10L M12 25L M12 40L M12 60L M16 15L M16 30L M16 60L M20 60L M20 100L M24 100L M24 150L
M6
M8
M10
M12
M16
M20 M24
55 70 85 65 80 95 75 90 115 140 90 105 120 140 125 150 180 195 235 255 300
10
12.5
45
13
17
50
17
21
60
19
24
75
24
30
115
30 36
37 50
130 150
6.5
12
50
35
70
6.5
5.0
9.0
14
55
40
80
15
7.5
11
16
65
50
100
27
13
13
20
85
60
120
50
23
0 10 30 25 60 25 100
17
25
125
95
190
120
22 26
32 38
140 160
115 125
220 240
230 400
44-015 44-020 44-025 44-055 44-060 44-065 44-105 44-110 44-115 44-120 44-155 44-160 44-165 44-170 44-205 44-210 44-215 44-255 44-260 44-305 44-310
RBL-M06/10 RBL-M06/25 RBL-M06/40 RBL-M08/10 RBL-M08/25 RBL-M08/40 RBL-M10/10 RBL-M10/25 RBL-M10/50 RBL-M10/75 RBL-M12/10 RBL-M12/25 RBL-M12/40 RBL-M12/60 RBL-M16/15 RBL-M16/30 RBL-M16/60 RBL-M20/60 RBL-M20/100 RBL-M24/100 RBL-M24/150
RAWLBOLT Shield
SHIELD LENGTH (mm) (s) HOLE DIAMETER IN STRUCTURE (mm) (do) MINIMUM HOLE DEPTH (mm) (ho) EFFECTIVE MINIMUM EMBEDMENT SUBSTRATE DEPTH THICKNESS (mm) (mm) (hef) (hmin) RECOMMENDED TORQUE (Nm) 30N/mm2
CONCRETE
REFERENCE
20.5N/mm2
BRICKWORK
PRODUCT CODE
NEW CODE
(Tinst)
(Tinst)
M6S M8S M10S M12S M16S M20S M24S 38 Technical Advisory Service
12 14 16 20 25 32 38
35 40 50 60 95 115 125
5.0 7.5 13 23
Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLBOLT
Speci cation Data
Reduction Factors - Edge and Spacing Distances for Rawlbolt Shield Anchor Loose Bolt The full characteristic edge and spacing distances shown in the table above are the minimum allowable for the quoted DESIGN RESISTANCE or RECOMMENDED LOAD, depending on your design method.
Where these dimensions are not achievable, the appropriate reduction factor/s from the tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD. Choose the required bolt diameter across the top of the appropriate table and read down the left hand column until actual edge or spacing distance is found.
Read off the reduction factor where the two lines intersect (interpolate as required). Multiply this factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted in the table. On the occasion that multiple close edge and/ or spacing distances occur, the appropriate reduction factors must be applied.
0.70 0.80 0.70 0.90 0.80 0.70 1.00 0.90 0.80 0.70 1.00 0.90 0.78 1.00 0.85 0.93 1.00
0.50 0.64 0.76 0.50 1.00 0.75 0.50 1.00 0.69 0.50 1.00 0.85 0.93 0.50 1.00 0.55 0.76 0.50 1.00 0.75 0.50 1.00 0.75 1.00
60 80 100 120 150 180 210 250 290 330 370 420
0.70 0.80 0.70 0.90 0.80 0.70 1.00 0.90 0.80 0.70 1.00 0.90 0.78 1.00 0.85 0.93 1.00
Brickwork Application
When installing into brickwork and there is a combined load in tension and shear, the resultant load must not exceed the quoted performance figure.
Installation
1. Drill a hole of required diameter and depth. Note: When fixing into brickwork, mortar joints should be avoided.
2. Remove debris and thoroughly clean hole with brush and pump.
3. Remove bolt and washer. Insert shield and place fixture over the hole.
4. Insert bolt with washer through the fixture and tighten to the recommended torque.
39