Ilc 150 Eth Inline Controller For Ethernet Networks With 8 Digital Inputs and 4 Digital Outputs
Ilc 150 Eth Inline Controller For Ethernet Networks With 8 Digital Inputs and 4 Digital Outputs
Ilc 150 Eth Inline Controller For Ethernet Networks With 8 Digital Inputs and 4 Digital Outputs
Module Data:
▲General Data
General Product
Information
Manufacturer: Phoenix
Contact
Device type: PLC
Product ILC1xx
range:
Order No.: 2985330
Version: 01/3.90
▲Function
The ILC 150 is a Remote Field Controller with IB local bus interface for the Inline installation system with
programming options according to IEC 61131-3 and a universal Ethernet gateway with TCP/IP transport
protocol.
▲Features
l Automation and control functions according to IEC 61131-3
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 2 of 7
▲Pin Assignment
terminal signal/
plug
point description
1 1.1 PWR US i1 i2 i5 i6
1 1.2 PWR UL
1 1.3 GND UL
1 1.4 Functional GND GND GND GND
earth
ground i3 i4 i7 i8
(FE)
1 2.1 PWR UM
1 2.2 PWR UM
1 2.3 GND UM,
US
1 2.4 Functional Fig. 2: Terminal assignment
earth
ground
(FE)
2 1.1 Output 1
2 1.2 GND
2 1.3 FE
2 1.4 Output 3
2 2.1 Output 2
2 2.2 GND
2 2.3 FE
2 2.4 Output 4
3 1.1 Input 1
3 1.2 PWR UM
3 1.3 GND
3 1.4 Input 3
3 2.1 Input 2
3 2.2 PWR UM
3 2.3 GND
3 2.4 Input 4
4 3.1 Input 5
4 3.2 PWR UM
4 3.3 GND
4 3.4 Input 7
4 4.1 Input 6
4 4.2 PWR UM
4 4.3 GND
4 4.4 Input 8
ETH RJ45 RJ45
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 3 of 7
▲PCP Services
Service
PCP read supported (client) True
PCP write supported (client) True
PCP get OD long supported (client) True
PCP program invocation supported (client) True
PCP download supported (client) True
PCP upload supported (client) True
PCP request domain upload supported (client) True
PCP information report supported (client) True
PCP read and write with name supported (client) True
Number of parallel PCP services (client) 1
PCP read supported (server) True
PCP write supported (server) True
PCP get OD long supported (server) False
PCP program invocation supported (server) False
PCP download supported (server) False
PCP upload supported (server) False
PCP request domain upload supported (server) False
PCP information report supported (server) True
PCP read and write with name supported (server) False
Number of parallel PCP services (server) 1
PCP PDU length (transmit direction) 246 byte
PCP PDU length (receive direction) 246 byte
PCP PNM7 PDU length (transmit direction) 246 byte
PCP PNM7 PDU length (receive direction) 246 byte
▲System Variables
Data
Name Description
Type
PLCMODE_ON PLC status ON BOOL
PLCMODE_LOADING PLC status LOADING BOOL
PLCMODE_RUN PLC status RUN BOOL
PLCMODE_STOP PLC status STOP BOOL
PLCMODE_HALT PLC status HALT BOOL
PLCDEBUG_BPSET Breakpoint set BOOL
PLCDEBUG_FORCE Variable(s) forced BOOL
PLCDEBUG_POWERFLOW Address status enabled BOOL
PLC_TICKS_PER_SEC System ticks per second INT
PLC_SYS_TICK_CNT Number of system ticks DINT
PLC_TASK_AVAILABLE Number of available PLC INT
tasks
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 4 of 7
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 5 of 7
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 6 of 7
▲Module Interfaces
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019
Page 7 of 7
Description
Ethernet
Internal interface
Internal interface
Internal interface
Outgoing IL local bus
Serial interface
▲Technical Data
General Data
Order designation ILC 150 ETH
file:///C:/Users/Public/Documents/FDCML10/ETHERNET/Phoenix%20Contact/Sho... 15/04/2019