Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GV

(13 ) F
KS(75 )

RANGE SINK RANGE SINK

FD(50 ) FD(50 ) FD(50 )

F,SHO
CB CB CB FD(50 )
VS(50 )
DS(75 ) DS(75 ) DS(75 ) DS(75 )
LD(75 ) DS(75 ) DS(75 ) HB (19 )

W.C.
W.C.
(100 )
VS(50 )

(13 ) F
LAV.(50 )

RANGE

RANGE

GV

(19) CWR
FD(50 )

(19) CWR
CB DS(75 )
DS(75 )
VS(50 ) VS(50 )
GV

(13 )F
SINK VSS(100 ) SINK

W.C.
VSS(100 )

(13 ) F
FD(50 ) HB (19 )
KS(75 )
LAV.(50 )
W.C. for WH(19 )

F,SHO
(100 )
GV
DS(75 ) DS(75 )

W.C.
(100 )

F,SHO
LAV.(50

(13 ) F
)
FD(50 )

W.C.
VS(50 ) VS(50 ) GV

FD(50 )

CB DS(75 ) DS(75 )
HB (19 )

FD(50 )

CB

DS(75 ) DS(75 ) DS(75 ) DS(75 )


FD(50 )
DS(75 )

CB CB CB CB
HB (19 )

GROUND FLOOR PLAN SECOND FLOOR PLAN ROOF DECK FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN ROOF DECK FLOOR PLAN

SEWER & STORM DRAINAGE LINE WATERLINE LAYOUT


SCALE 1:100 m. SCALE 1:100 m.

INLET PIPE (VERIFY STORM

SPECIFICATIONS: CEMENT PLASTERED 100mm.


THK CHB
DRAIN PLAN)

1. ALL SANITARY WORKS INCLUDE HEREIN SHALL BE EXECUTED


0.50

2.50
600X600mm
CONCRETE COVER
ACCORDING TO THE PROVISIONS OF THE NATIONAL
PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL LEGEND 0.30
125mm THK R.C. SLAB BUILDING CODE OF THE PHILIPPINES, AND ITS IMPLEMENTING
LIFTING HANDLE RULES AND REGULATIONS. WC WATER CLOSET
0.29 0.10

2. COORDINATE WITH THE DRAWING WITH OTHER RELATED SS SOIL STACK


0.10 1.40 0.10 0.80 0.10 DRAWINGS AND SPECIFICATIONS. THE ARCHITECT AND/OR
ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY LAV. LAVATORY
DISCREPANCY FOUND HEREIN. HIS/HER SHALL BE FINAL.
150mm PVC KS KITCHEN SINK
0.60 0.60
OUTLET TO
3. ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY
STREET DRAINAGE
RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER LS LAUNDRY SINK
150mm ON CENTER
BOTHWAYS
5" THK CHHB
TRADES SHALL BE WITH APPROVAL OF THE ARCHITECT
AND/OR ENGINEER.
FD FLOOR DRAIN PLAN
CEMENT PLASTERED 100mm. CEMENT MORTAR
OUTLET TO VSTR VENT STACK THRU ROOF
2.07

STREET DRAINAGE 4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE BARS @ EVERY 3 COURSE
1.50

ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF 100mm. THK SAND CUSHION
CB CATCH BASIN
EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE
0.60

CONTRACTOR. DS DOWNSPOUT
MANHOLE
0.50
SP. @ EVERY 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SD SHOWER DRAIN 0.30
0.60
1.50

1.30

2 LAYERS OF CHB REQUIRED FLOOR AND WALL OPENINGS.

VERIFY STORM DRAINAGE PLAN


BT BATH TUB
MANHOLE FFL FFL
6. MINIMUM SLOPE FOR HORIZONTAL WASTE SHALL BE 2%.
sho. SHOWER
0.60

DEPTH (D VARIES)
0.20

7. ALL WATER SUPPLY INDIVIDUAL BRANCHES TO FIXTURES OR

0.70 MINIMUM
MANHOLE
co CLEAN OUT CORNERS AND CENTER OF
GROUP OF FIXTURES AND/OR EQUIPMENT SHALL BE
CHB
PROVIDED WITH PIPE EXTENSION OF 0.30m AS MINIMUM F FAUCET
@ 250mm ON CENTER LENGTH
600X600mm GV GATE VALVE
CONCRETE COVER EACHWAY 8. ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE NOTED. PVC SDP @ 2% MIN. SLOPE
(VERIFY STORM DRAIN PLAN)
CV CHECK VALVE
LIFTING HANDLE
9. ALL VERTICAL DOWN FEED SUPPLY PIPE SHALL BE PROVIDED
WITH ONE(1) GATE VALVE GOING TO EACH TOILET UNIT. AV ANGLE VALVE
@ 250mm ON CENTER REINFORCED CONC. SLAB W/

SECTION
0.60x0.60x0.10m R.C. 10mm. RSB @ 0.20m.o.c.
MANHOLE COVER w/ WM WATER METER BOTHWAYS
10. 1% SLOPE FOR HORIZONTAL VENTS NOT LESS THAN 6" ABOVE

PLAN
10mm COMPRESSED SOIL OR
HANDLE (TYPICAL) WATER LEVEL OF FIXTURES. CWL NATURAL EARTH

GRAVEL BEDDING
11. INLET PIPES SHALL BE 2" HIGHER THAN THE PIPE TO SEWER
SEPTIC TANK DETAIL LEACHING WELL AND SHALL BE 2" HIGHER THAN THE OUTLET
PIPE.
LINE
SECTION
12. VENT SOIL STACK SHALL BE EXTENDED FULL SIZE THROUGH
THE ROOF AND SHALL BE 2.0m ABOVE CATCH BASIN DETAIL

CERTIFIED BY: PRC NO: 145334 PROJECT TITLE: APPROVED BY: REVISIONS: SHEET CONTENTS SHEET NO.

PTR NO:

ISSUED ON:
OWNER

ISSUED AT: NAGA CITY LOCATION: Lot 8, BLK 10, Phoenix st. RJ Village, Haring, Canaman, camarines Sur ADDRESS: Purisima, Quipayo, Calabanga, Camarines Sur
ADDRESS:La