निमज्जनीय पम्पसेटस — विशिष्टि


(  तीसरा पनु रीक्षण )

Submersible Pumpsets —
Specification
( Third Revision )

ICS 23.100.10

© BIS 2018

भारतीय मानक ब्रयू ो


B U R E A U O F I N D I A N S TA N D A R D S
मानक भवन, 9 बहादरु शाह ज़फर मार्ग, नई िदल्ली – 110002
MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI-110002
         www.bis.gov.in  
www.standardsbis.in

August 2018  Price Group 8


Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

Pump Sectional Committee, MED 20

FOREWORD
This Indian Standard (Third Revision) was adopted by the Bureau of Indian Standards, after the draft finalized by
the Pumps Sectional Committee had been approved by the Mechanical Engineering Division Council.
This standard was first published in 1976 and subsequently revised in 1989 and 2002.
In this revision, all the amendments have been reviewed and incorporated. Following important changes are made
in this revision:
a) Latest Materials of Construction (MOC) covering all types of manufacturing process have been
incorporated for shaft sleeve, casing wear ring, bush, discharge casing/non-return valve housing, impeller,
pump bowl/diffuser and suction casing.
b) Requirements have been specified for gaskets, seals and packing’s.
c) Cables conforming to IS 694 have been specified.
d) Different types of submersible motors suitable for borewell submersible pumpsets have been specified
based on their constructional features.
e) Increased pump efficiency values have been incorporated in the pump efficiency charts.
For the purpose of deciding whether a particular requirement of this standard is complied with the final value,
observed or calculated, expressing the result of a test or analysis shall be rounded off in accordance with
IS 2 : 1960 ‘Rules for rounding off numerical values (revised )’. The number of significant places retained in the
rounded off value should be the same as that of the specified value in this standards.
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Indian Standard
SUBMERSIBLE PUMPSETS —
SPECIFICATION
( Third Revision )

1 SCOPE c) Total solids : 3 000 ppm, Max


This Standard specifies the requirements for d) pH : 6.5 to 8.5
submersible pumpsets (single/multi stage) using single/
three phase AC induction motor, commonly used in e) Temperature : 33ºC, Max
boreholes (borewells or tubewells) for handling clear, f) Specific gravity : 1.004, Max
cold water for application in agriculture and water
NOTES — If any characteristics of the water differ from
supplies purposes. those specified in 4, the pump details shall have to be agreed
between the manufacturer/supplier and the user In such cases,
2 REFERENCES the characteristics shall be specified in the order.

The standards listed in Annex A contain provisions


which, through reference in this text, constitute 5 NOMENCLATURE
provision of this standard. At the time of publication,
Nomenclature of the parts commonly used in
the editions indicated were valid. All standards are
submersible pumpsets shall be as given in Fig. 1.
subject to revision, and parties to agreements based
on this standard are encouraged to investigate the 6 CONSTRUCTIONAL FEATURES
possibility of applying the most recent editions of the
standards indicated in Annex A. 6.1 General
3 UNITS The submersible pumpsets described herein generally
comprise the following:
Units relating to pumps as specified in 2 of IS 5120
a) Pump sub-assembly,
shall be applicable.
b) Motor sub-assembly,
4 TERMINOLOGY c) Coupling,
Terminology relating to pumps as specified in 3 of d) Non-return valve,
IS 5120 shall be applicable. In addition, the following e) Discharge casing (if provided) either integral or
shall also apply: separate, and
4.1 Static Water Depth f) Cable and cable guards.
It is the depth of water level below the ground level 6.2 Material of Construction
when the pump is not in operation. There are number of recognized materials of
construction available to meet the needs of submersible
4.2 Draw-Down
pumpsets handling clear, cold water. Typical materials
It is the elevation difference between the depth of static for few components are indicated below merely for
water level and the consistent standing water level in guidance to the manufacturer and user:
tube well during pump in operation.
Sl Component Material of Construction
4.3 Submergence No. (Parts Made of Casted/Moulded/
Sheet Metal Fabricated Process)
It is the minimum height of water level after draw-
down above the suction casing. (1) (2) (3)
i) Shaft sleeve Bronze grade LTB 2, 3, 4 or 5 of
4.4 Characteristics of Clear, Cold Water IS 318 or 12 percent chromium
steel grade X 04 Cr 12, X 12 Cr 12
Clear, cold water shall mean water having the and X 20 Cr 13, X04Cr19Ni-9/10
characteristics specified below: conforming to IS 6911 or IS 6603
ii) Casing wear ring (if Bronze grade LTB 2, 3, 4 or 5 of
a) Turbidity : 50 ppm, (Silica Scale) Max provided) IS 318 or nitrile rubber or NBR
or plastic/technopolymer or
b) Chlorides : 500 ppm, Max
X04Cr19Ni-9/10 of IS 6911

1
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Sl Component Material of Construction Sl Component Material of Construction


No. (Parts Made of Casted/Moulded/ No. (Parts Made of Casted/Moulded/
Sheet Metal Fabricated Process) Sheet Metal Fabricated Process)
(1) (2) (3) (1) (2) (3)
iii) Bush Bronze grade LTB 2, 3 or 4 of  IS 318 vii) Pump shaft Stainless steel grade X 04 Cr 12,
or nitrile/cutless rubber or NBR X 12 Cr 12 or X 20 Cr 13 or
X15Cr16Ni2 of IS 6603
iv) Discharge casing/ Cast iron grade FG 200 of
Non return valve IS 210 or plastic/technopolymer or viii) Suction casing Cast iron grade FG 200/FG 260 of
housing (if provided) X04Cr19Ni-9/10 of IS 6911 IS 210 or X04Cr19Ni-9/10
v) Impeller Bronze grade LTB 2 of IS 318 or NOTE — The materials listed are to be considered as
stainless steel grade X 12 Cr 12 only typical and indicative of minimum requirements of
or X04Cr19Ni-9/10 of IS 6911 or the material properties. The use of materials having better
IS 6603 or plastic/technopolymer properties is not prejudiced by the details above provided
vi) Pump bowl/diffuser Cast iron grade FG 200 of materials for components in bearing contact with each other
IS 210 or plastic/technopolymer or do not entail galling, corrosion, magnetic induction, etc
X04Cr19Ni-9/10 of IS 6911

1A RADIAL FLOW PUMP 1B MIXED FLOW PUMP


NOTE — These figures illustrate the nomenclature of commonly used parts and do not specify any particular design feature.

Fig. 1 Nomenclature of Submersible Pumpsets in General

2
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

6.2.1 To benefit from the advancement in technology 6.2.2.2 The motor/motor portion shall be provided with
of plastics, thermoplastic materials, such as, a breathing attachment like bellows, diaphragm etc. to
polyphenylene oxide (PPO), polycarbonate, acetal, compensate the volumetric change of water inside the
nylon 66, polytetrafluoroethylene (PTFE), acrylonitrile motor due to change in the temperature.
butadiene styrene (ABS), polyester PETP, etc, may be
used for pump parts like shaft sleeve, casing, impeller 6.2.3 The motor/motor portion shall be protected from
wearing ring, bowl/diffuser, etc. Typical materials of ingress of borewell water, sand and other foreign matter
the parts and their properties are indicated below for by means of cable glands, rubber seals etc.
the guidance to the manufacturer and the user: 6.2.4 All the materials and components for the motor
shall be suitable for application in respect of corrosion
Sl Name of Material of the Moulded Part
No. the Part
resistance and mechanical performance continuously
under water.
(1) (2) (3)
i) Impeller Glass filled polyphenylene oxide1) (modified 6.2.5 The rotor of the wet type (water filled) submersible
PPO), glass filled polycarbonate1) for which motor shall be provided with suitable coating to protect
properties shall be as given below: it from corrosion under water.
Properties Modified Polycarbonate
Polyphenylene 7 DESIGN FEATURES
Oxide
Hardness M 90/L 106 M 91 7.1 Typical Design Features of Components of Pump
(Rockwell) for Guidance
Coefficient 4 × 10-5, Max 3 × 10-5, Max
of linear, 7.1.1 The pump shaft may be guided through bearings.
m/m°C Bearings may be provided in mixed flow pumps for
thermal each stage. In case of radial flow pump, bearings may
expansion be provided in suction and discharge casing, while in
Water 0.06, Max 0.29, Max case of intermediate bearings, suitable positions may
absorption, be selected in the overall span.
24 h at 23°C,
percent 7.1.2 The pump may be equipped with replaceable
Notched 80, Min 100, Min bearing and wearing ring, wherever provided.
impact
strength Izod, 7.1.3 The inlet passages of the suction casing may be
J/m designed to reduce entry losses of the inlet flow.
Specific 1.21 ± 0.03 1.35 ± 0.03
gravity 7.1.4 The strainer on the suction casing may offer the
Tensile 90, Min 90, Min
best compromise between restraining the large solids
strength at from entering the pump and retaining the suction losses
break, N/mm2 to the minimum.
Elongation at 4-6 3
break, percent
7.1.5 The outer periphery of the pump casing may have
provision for securing the cable and cable guards over
Mould 0.2-0.4 0.2-0.5
shrinkage,
the cable, so as to prevent damage to the cable.
percent
7.1.6 The construction of borewell shall conform to
Glass content, 20, Min 20, Min IS 2800 (Part 1 and Part 2). The maximum outside
percent
diameter of pumpsets corresponding to nominal diameter
ii) Bowl/ Polyphenylene oxide (modified PPO), of the tubewell is as given below: (As per IS 14536)
diffuser polycarbonate, polyacetal or polypropylene
iii) Wearing PTFE, ABS or Nylon 66 Sl Nominal Diameter Maximum Outside
ring No. of the Tubewell Diameter of
iv) Shaft sleeve Polyethylene (LD/HT), Nylon 66, PTFE, Submersible Pumpsets
polypropylene (mm) (mm)
1)
 Glass filling is extremely essential for these grades of plastics in view (1) (2) (3)
of abrasion resistance and better life to the end users.
i) 100 98
ii) 115 108
6.2.2 Gaskets, Seals and Packings
iii) 150 146
6.2.2.1 Gaskets, seals and packings used for clear, iv) 200 196
cold water pumps shall conform to the applicable v) 250 245
requirements specified in 5.2 of IS 5120. vi) 300 296

3
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

7.1.7 The pump loading shall be as per 11.1.5. be 0.75 µm Ra Max, pertaining to the bearing contact
surfaces.
7.1.8 The pump efficiency shall be as per 11.4.
8.5 Balancing
7.1.9 The prime mover electric motor suitable for
the pumps shall be of continuous duty as specified in 8.5.1 In case of 2-pole submersible pumpset, the
IS/IEC 60034-1 and as per IS 9283. impeller and rotor shall be dynamically balanced to
grade G6.3 of IS/ISO 1940-1.
7.1.10 Voltage and Frequency Variation
8.5.2 In case of 4-pole submersible pumpset, the
Submersible motor shall be capable to operate in the impeller shall be statically or dynamically balanced and
voltage and supply frequency for category “A” or rotor shall be dynamically balanced to grade G6.3 of
category “B” as per IS 9283. IS/ISO 1940-1.
7.1.10.1 Category ‘A’ 8.5.3 The plastic and sheet metal impeller need not be
The motors shall be capable of delivering rated output balanced.
with:
8.5.4 Balancing here means the balancing of the
a) The terminal voltage differing from this rated unbalanced rotating mass in the impeller and not
value by not more than ± 6 percent; balancing of the axial hydraulic thrust in the impeller.
b) The frequency differing from its rated value by not
more than ± 3 percent; and 8.6 Cable
c) Any combination of (a) and (b). 8.6.1 Flat/Round cables (3/4 core type) insulated and
sheathed with suitable polymer as per IS 694 shall be
7.1.10.2 Category ‘B’
used.
The motor shall be capable of delivering rated output
with: 8.6.2 The size of the conductor shall be adequate and
suitable for continuous use under water and in air. The
a) The terminal voltage differing from this rated
length of the cable shall be minimum 2 m externally,
value by not more + 6 percent and –15 percent;
unless otherwise specified by the customer.
b) The frequency differing from its rated value by not
more than ± 3 percent; and 8.6.3 The size of the conductor and the length of cable
c) Any combination of (a) and (b). should be suitably selected so that the voltage drop
between the control panel and the motor terminal does
7.1.11 The manufacturer shall have a system of not exceed three percent of the rated voltage.
controlling dimensional accuracy within a scheme
of fits and tolerance limits. The system shall help 8.6.4 In case a joint is required to be made between the
interchangeability and fitment at site of replacement lead cable supplied with the motor and the user’s cable,
spares during repair and maintenance. a detailed procedure to make water tight joining shall
be supplied by the motor manufacturer.
8 GENERAL REQUIREMENTS
8.6.5 If four core cable is used, the fourth core is to be
8.1 The general requirements for the pump shall used for earthing.
conform to the applicable requirements specified in 17
8.7 Direction of Rotation
of IS 5120.
8.7.1 The direction of rotation of pumpsets is designated
8.2 Casing
clockwise or anti-clockwise as observed when looking
Pump casing shall be of robust construction and shall at the pump stage from the driving end.
be tested to withstand hydrostatic pressure test as
specified in 10.3. 8.7.2 The direction of rotation shall be clearly and
securely marked by incorporating an arrow on the
8.3 Impeller pumpset.
The impeller may be of enclosed or semi-open type.
8.8 Terminal Marking
8.4 Shaft Terminal markings shall be in accordance with
IS/IEC 60034-8.
8.4.1 The shaft shall be of adequate size to transmit the
required power. 8.9 Typical Installation
8.4.2 The surface finish of the shaft or of the protecting 8.9.1 Since the motor and the pump are directly coupled,
sleeve of the pumpsets having journal bearings shall or closed coupled, the manufacturer shall indicate the

4
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

minimum size of the borehole in which the submersible of the manufacturer. A typical sketch of submersible
pumpset shall be erected and suspended freely. pumpset installation is shown in Fig. 2.
8.9.2 The pumpset shall be installed as per guidelines 8.9.3 The manufacturer shall specify the minimum
laid down in IS 14536 or as per the recommendation submergence of pump unit at duty point.

6 m min.

Fig. 2 Typical Submersible Pumpset Installation

5
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

8.9.4 Provision for Earthing with this standard provided they comply in all
respects except full load current (maximum),
8.9.4.1 Earthing of the motor shall be done as per which shall be changed in inverse proportion of the
IS 9283 in accordance with the relevant provisions voltage.
of IS 3043.
8.10.2.3 Ratings
8.9.4.2 In case of PVC pipes used as discharge pipe, a
separate non corrosive, low resistance conductor from The preferred output ratings of the motors for
motor earth terminal to control panel earth terminal submersible pumpsets shall be 1.1, 1.5, 2.2, 3, 3.7, 4.5,
shall be provided for earthing. 5.5, 7.5, 9.3, 11, 13, 15, 18.5, 22, 26, 30, 37, 45, 55, 63,
67 and 75 kW.
8.9.4.3 In case non corrosive GI pipes and clamps are
used for the purpose of earthing the motor, earthing 8.10.2.4 Types of motors
connection may be made to the discharge pipe clamp Three phase squirrel cage induction motors
and to the control panel earth terminal.
8.10.2.5 Rated speed
8.10 Submersible Motors
Preferred rated speed shall be those corresponding to
Submersible motors suitable for borewell submersible two pole and four pole motors.
pumpsets are classified based on their construction are
as follows:
9 TESTS FOR ELECTRICAL PERFORMANCE
a) Wet type water filled submersible motors; ON SUBMERSIBLE MOTOR
b) Wet type oil filled submersible motors; and
c) Resin filled submersible motors. 9.1 General

8.10.1 Single Phase Motors 9.1.1 Routine and type test on submersible motor shall
be performed as specified in 16.1and 16.2 of IS 9283.
8.10.1.1 Rated voltage and rated frequency The general requirements of the motor with regard
to site conditions, voltage and frequency, Type of
8.10.1.2 The preferred rated voltage and frequency enclosures, methods of cooling, materials, duty-rating,
shall be 240 V and 50 Hz respectively. terminal marking and earthing shall be in accordance
8.10.1.3 Motor designed for operation at voltages other with IS 9283.
than 240 V shall be considered as complying with this 9.1.2 While conducting routine and type tests on
standard provided they comply in all respects except submersible motor for electrical performance, supply
full load current (maximum), which shall be changed voltage shall be the rated voltage and frequency shall
in inverse proportion of the voltage. be within ± 3 percent of rated frequency.
8.10.1.4 Ratings 9.1.3 In case of three-phase submersible motor, the
The preferred output ratings of the motors for value of the current (amperes) shall be the average
submersible pumpsets shall be 0.37, 0.55, 0.75, 1.1, 1.5 value of currents (amperes) measured in all the three
and 2.2 kW. phases.
8.10.1.5 Types of motors 9.1.4 Performance values of 2 pole three phase motors
a) Capacitor Start Induction Run motor (CSIR); of less than 1.1 kW and exceeding 75 kW rating shall
be as declared by the manufacturer.
b) Capacitor Start and Run motor (CSR); and
c) Capacitor Start and Capacitor Run motor (CSCR). 9.1.5 However for three phase motors above 75 kW
rating, the declared value of efficiency shall not be
8.10.1.6 Rated speed lesser than 75 kW value.
Preferred rated speed shall be those corresponding to 9.1.6 Performance values of 2 pole single phase motors
two pole and four pole motors. of other ratings below 0.37 kW and exceeding 2.2 kW
shall be declared by the manufacturer.
8.10.2 Three Phase Motors
9.1.7 However for single phase motors above 2.2 kW
8.10.2.1 Rated voltage and rated frequency
rating, the declared value of efficiency shall not be
The preferred rated voltage and frequency shall be lesser than 2.2 kW value.
415 V and 50 Hz respectively.
9.1.8 Performance values of 4 pole single phase
8.10.2.2 Motor designed for operation at voltages and three phase motors shall be as declared by the
other than 415 V shall be considered as complying manufacturer.

6
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

9.1.9 However, in case of pumpset, motor need not be 9.6 Determination of Temperature Rise of Winding
tested for full load test. by Resistance Method
9.2 Insulation Resistance Test The temperature rise (t2 – t1) may be obtained from the
ratio of the resistance by the formula:
Insulation resistance tests shall be as per IS 9283.
((t2 + 235) / (t1 + 235)) = R2 / R1
9.3 High Voltage Test
where,
High voltage test shall be as per IS 9283.
ta = temperature (°C) of external cooling medium
9.4 Leakage Current Test (water), at the end of the test;
The maximum leakage current value shall be not more t2 = temperature (°C) of the winding, at the end of
than 50 mA at rated voltage at no load. The motor shall the test;
be placed on either a rubber mat or a wooden base or any R2 = resistance of the winding, at the end of the
other insulated base. A voltage equal to rated voltage test;
shall be applied to any supply line and accessible
outside metal parts of the motor. The resistance of the t1 = temperature (°C) of the winding (cold), at the
test circuit shall be 2 000 ± 50 Ω. moment of the initial resistance measurement;
and
NOTE — For safety purpose it shall be ensured during
installation that the earthing is capable of taking care of R1 = initial resistance of the winding (cold).
leakage current.
For practical purposes, the following alternative
9.5 Temperature Rise Test formula may be found convenient:

9.5.1 Temperature rise test for winding shall be carried (t2 – ta ) = (R2 – R1) / R1) * (235 + t1) + (t1 – ta )
out on sample pumpset:
9.7 Breakaway (Starting)Torque Test
a) At rated voltage and supply frequency within
± 3 percent of rated frequency, and 9.7.1 The minimum value of breakaway (starting)
b) At 85 percent of rated voltage and supply torque as percentage of rated/full load torque, with
frequency within ± 3 percent of rated frequency. the rated voltage and frequency applied across the
terminals shall be as given in the Table 1, 2, 3, 4 and 5
9.5.2 Temperature Rise Test at Rated Voltage for three phase and single phase motors for applicable
motor types/rating.
9.5.2.1 Run the pumpset at rated voltage and maximum
current in the operating head range for 2 h. Stop the 9.7.2 This test may be made at a reduced voltage, when
pumpset and measure the winding resistance and water a current at least equivalent to full load current is being
temperature within 30 s. taken by the motor.
9.5.2.2 Temperature rise computed by resistance 9.8 Speed
method shall not exceed 35°C.
9.8.1 Preferred rated speed shall be those corresponding
9.5.3 Temperature Rise Test at Reduced Voltage to two pole and four pole.
9.5.3.1 Carryout this test immediately after the test 9.8.2 The speed shall be measured as per IS 9283.
at rated voltage. Run the set at maximum current
in operating head range at rated voltage. Reduce the 9.9 Routine Test
voltage to 85 percent of rated voltage in this condition. Following shall constitute the routine test for electrical
Run the pumpset for 1 h and measure the winding performance on submersible motor shall be as per
resistance and water temperature within 30 s. IS 9283:
9.5.3.2 Temperature rise computed by resistance a) Insulation resistance test (Before high voltage test
method shall not exceed 45°C. only);
b) High voltage test;
9.5.4 During the tests the water temperature shall not
exceed 45°C. c) No load running of motor and reading of current,
voltage, power and speed; and
9.5.5 For conducting temperature rise test, the pump d) Locked rotor reading of voltage, current and
itself shall be used for loading the motor. power.
9.5.6 The temperature rise test at reduced voltage shall The requirements and values shall be in accordance
not be applicable for category ‘A’ submersible motors. with those specified in IS 9283 as may be applicable.

7
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Table 1
( Clause 11.3.1 and 11.4.2 )
Values of Performance Characteristics for 2-Pole, 415 Volt, 50 Hz Three Phase, Water Filled Submersible
Motors for Bore Size Nominal 100 mm Shall Have Maximum OD of Motor 98 mm.
Sl Motor Maximum Current Permissible Limit of Maximum Minimum Starting Torque Motor
No. Rating Current in the Operating (In the terms of Percentage Efficiency
Head Range for Checking the of Full Load Torque) Factor
Non-Overloading Requirements
kW A A Percent
(1) (2) (3) (4) (5) (6)
i) 1.1 4.0 4.3 125 56
ii) 1.5 4.8 5.1 125 60
iii) 2.2 6.9 7.4 125 63
iv) 3.0 9.0 9.6 125 63
v) 3.7 10.6 11.3 125 64
vi) 4.5 12.6 13.5 125 67
vii) 5.5 15.5 16.6 125 68

NOTES
1 Maximum current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage.
2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases.
3 Values given in Col. 4 are 1.07 times of the values given in Col. 3.
4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 1.1 kW and exceeding 5.5 kW rating
shall be as declared the manufacturer.
5 However, for three phase motors above 5.5 kW rating, the declared value of efficiency shall not be lesser than 5.5 kW value.
6 Motor efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum-overall efficiency of the pumpset.

Table 2
( Clause 11.3.1 and 11.4.2 )
Values of Performance Characteristics for 2-Pole, 415 Volt, 50 Hz Three Phase, Water Filled Submersible
Motors for Bore Size Nominal 150 mm Shall Have Maximum OD of Motor 146 mm
Sl Motor Maximum Current Permissible Limit of Maximum Minimum Starting Torque Motor
No. Rating Current in the Operating (In the terms of Percentage Efficiency
Head Range for Checking the of Full Load Torque) Factor
Non-overloading Requirements
kW A A Percent
(1) (2) (3) (4) (5) (6)
i) 1.1 3.3 3.5 125 57
ii) 1.5 4.5 4.8 125 66
iii) 2.2 6.5 6.9 125 67
iv) 3.0 8.5 9.1 125 67
v) 3.7 10.0 10.7 125 68
vi) 4.5 12.0 12.8 125 70
vii) 5.5 14.5 15.5 125 73
viii) 7.5 19.5 20.9 125 74
ix) 9.3 25.0 26.7 125 75
x) 11.0 29.0 31.0 125 76
xi) 13.0 34.0 36.4 125 77
xii) 15.0 39.0 41.7 125 78

NOTES
1 Maximum current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage.

8
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Table 2 ( Concluded )

2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases
3 Values given in Col. 4 are 1.07 times of the values given in Col. 3.
4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 1.1 kW and exceeding 15.0 kW rating
shall be as declared the manufacturer.
5 However, for three phase motors above 15.0kW rating, the declared value of efficiency shall not be lesser than 15.0kW value.
6 Motor efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum-overall efficiency of the pumpset.

Table 3
( See 11.3.1 and 11.4.2 )
Values of Performance Characteristics for 2-Pole, 415 Volt, 50 Hz Three Phase, Water Filled Submersible
Motors for Bore Size Nominal 200 mm shall have Maximum OD of Motor 196 mm
Sl Motor Maximum Current Permissible Limit of Maximum Minimum Starting Torque Motor
No. Rating Current in the Operating Head (In the terms of Percentage Efficiency
Range for Checking the Non- of Full Load Torque) Factor
overloading Requirements
kW A A Percent
(1) (2) (3) (4) (5) (6)
i) 3.0 8.5 9.1 125 69
ii) 3.7 10.0 10.7 125 70
iii) 4.5 12.0 12.8 125 72
iv) 5.5 14.5 15.5 125 75
v) 7.5 19.5 20.9 125 76
vi) 9.3 25.0 26.7 125 77
vii) 11.0 29.0 31.0 125 78
viii) 13.0 34.0 36.4 125 79
ix) 15.0 39.0 41.7 125 80
x) 18.5 48.0 51.3 125 80
xi) 22.0 57.0 61.0 125 80
xii) 26.0 66.0 70.6 125 81
xiii) 30.0 76.0 81.3 125 81
xiv) 37.0 85.0 91.0 125 82
xv) 45.0 100.0 107.0 125 82
xvi) 55.0 120.0 128.4 125 83
xvii) 63.0 135.0 144.5 125 83
xviii) 67.0 144.0 154.1 125 84
xix) 75.0 158.0 169.1 125 84
NOTES
1 Maximum current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated
voltage.
2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases
3 Values given in Col. 4 are 1.07 times of the values given in Col. 3.
4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 1.1 kW and exceeding 75.0 kW rating
shall be as declared the manufacturer.
5 However, for three phase motors above 75.0 kW rating, the declared value of efficiency shall not be lesser than 75.0 kW value.
6 Motor efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum-overall efficiency of the pumpset.

9
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Table 4
( Clause 11.3.1 and 11.4.2 )
Values of Performance Characteristics for 2-Pole, 240 Volt, 50 Hz Single Phase, Capacitor Start and
Run (CSR), Capacitor Start and Capacitor Run (CSCR), Water Filled Submersible Motors for
Bore Size Nominal 100 mm shall have Maximum OD of Motor 98 mm
Sl Motor Maximum Permissible Limit of (CSR) (CSCR) Motor
No. Rating Current Maximum Current in the Minimum Starting Minimum Starting Efficiency
Operating Head Range Torque (In the terms of Torque (In the terms of Factor
for Checking the Non- Percentage of Full Load Percentage of Full Load
overloading Requirements Torque) Torque)
kW A A Percent Percent
(1) (2) (3) (4) (5) (6) (7)
(i) 0.37 5.3 5.7 30 125 40.0
(ii) 0.55 6.2 6.6 30 125 42.0
(iii) 0.75 7.5 8.0 30 125 46.0
(iv) 1.1 10.5 11.2 30 125 49.0
(v) 1.5 13.8 14.8 30 125 52.0
(vi) 2.2 19.8 21.2 30 125 56.0

NOTES
1 Maximum current limits specified are for 240 V rated voltages. For other voltages, it shall be in inverse proportion to rated voltage.
2 Values given in Col. 4 are 1.07 times the values given in Col. 3.
3 For Motors of other ratings below 0.37 kW the performance values shall be declared by the manufacturer.
4 Motor efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset.

Table 5
( Clause 11.3.1 and 11.4.2 )
Values of Performance Characteristics for 2-Pole, 240 Volt, 50 Hz Single Phase Capacitor Start and Run
(CSR), Capacitor Start and Capacitor Run (CSCR), Oil Filled / or Encapsulated Oil Filled, Submersible
Motors for Bore Size Nominal 100 mm shall have Maximum OD of Motor 98 mm
Sl Motor Maximum Permissible Limit of (CSR) (CSCR) Motor
No. Rating Current Maximum Current in the Minimum Starting Minimum Starting Efficiency
Operating Head Range Torque (In the terms of Torque (In the terms of Factor
for Checking the Non- Percentage of Full Load Percentage of Full Load
overloading Requirements Torque) Torque)
kW A A Percent Percent
(1) (2) (3) (4) (5) (6) (7)
(i) 0.37 4.1 4.4 30 125 43.0
(ii) 0.55 5.0 5.3 30 125 45.0
(iii) 0.75 6.7 7.1 30 125 50.0
(iv) 1.1 9.5 10.1 30 125 53.0
(v) 1.5 12.5 13.3 30 125 56.0
(vi) 2.2 16.0 17.1 30 125 62.0

NOTES
1 Maximum current limits specified are for 240 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage.
2 Values given in Col. 4 are 1.07 times the values given in Col. 3.
3 For Motors of other ratings below 0.37 kW the performance values shall be declared by the manufacturer.
4 Motor efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset.
5 For 2-pole, 415 V, 50 Hz three phase, oil filled or encapsulated oil filled, submersible motors for bore size minimum 100 mm and
maximum OD of Motor 98 mm, performance values shall be as declared by the manufacturer.’

10
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

9.10 Type Test 10.2.1 Measurement of Total Head (see Fig. 3 of


Following shall constitute the type test for electrical IS 11346)
performance on submersible motor shall be as per The total head is made up of:
IS 9283: a) Vertical distance between pumping water level to
a) Insulation resistance test (Both before and after gauge centre distance, in metres (Z);
the high voltage test); b) Delivery gauge reading, in metres, in water
b) High voltage test; column (h); and
c) Measurement of stator resistance; c) Velocity head, in metres (Vd2/29).
d) No load running of motor and reading of voltage Therefore, total head H = Z + h + Vd2/29.
current, power input and speeds;
e) Reduced voltage running up test at no load to 10.2.2 Flow Measurement
check the ability of the motor to run up to full speed Measurement of flow shall conform to 3.1.1 of
on no load with 60 percent of the rated voltage IS 11346.
applied to the motor for three phase motors and
75 percent of the rated voltage applied to the 10.2.3 For current and power measurement, ammeter
motor for single phase motors; and watt meter of adequate capacity shall be used.
f) Locked rotor reading of voltage, current and 10.3 Hydrostatic Pressure Test
power and torque of motors;
Hydrostatic pressure test shall be carried out on
g) Breakaway (starting) torque; individual pressure boundary part or pump as a whole
h) Leakage current test at rated voltage at no load; in assembled condition at 1.5 times the maximum
j) Temperature rise test at rated voltage; pressure (at zero discharge) and this pressure shall be
k) Temperature rise test at reduced voltage; and maintained for 2 min and no leakage shall be observed.
m) Momentary over-load test (as per agreement 11 GUARANTEE AND TOLERANCES ON
between the manufacturer and the purchaser). PUMPSET PERFORMANCE
NOTES
1 Temperature rise test however shall be done as per 11.1 Guarantee of Performance
Clause 9.5.
2 Reduced voltage Temperature rise test shall not be applicable 11.1.1 The pumpset shall be guaranteed for their
for Category ‘A’ submersible motors. performance of the nominal volume rate of flow and
the nominal head at the guaranteed point. The overall
The requirements and values shall be in accordance efficiency of the pumpset shall be guaranteed at the
with those specified in IS 9283 as may be applicable. declared point only.
10 TEST FOR HYDRAULIC PERFORMANCE 11.1.2 The guarantee shall be deemed to have been
ON PUMP FOR SUBMERSIBLE PUMPSET met with, if the measured values of head, volume
rate of flow and overall efficiency are within the
10.1 Sampling limits indicated as per 8 of IS 11346. However,
The sampling and criteria of conformity for hydraulic after applying the tolerance, overall efficiency value
performance shall be as per IS 10572, except for lot shall not be less than that derived from Fig. 4 and
size up to 25. The sampling for lot size up to 25 shall Fig. 5.
be as given below: The pumpset shall be tested at rated conditions and
the maximum current consumption of the pumpset at
Lot Size Sample Size the operating head range shall be verified. The actual
(1) (2) verified current shall not be less than 75 percent of the
maximum declared current at the rated voltage.’
Up to 7 1
NOTE — The above clause is to ensure proper rating of
8 to 15 2 pumpset.
16 to 25 3 11.1.3 The pumpset shall be guaranteed at the nominal
duty point. The same pumpset may also be deemed to
10.2 Laboratory Tests have met the guarantee if the users required duty point
Testing procedures as given in IS 11346 shall be lies within the specified tolerance of head (± 4 percent)
followed. A typical testing arrangement for submersible and discharge (± 7 percent) of the nominal duty point
pumpset is given in Fig. 4. and also meets the non-overloading requirements.

11
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

Fig. 3 Typical Testing Arrangement for Submersible Pumpsets

12
13
NOTES
1 The efficiency in figure represents three or more stages:
a) For two stage pump, multiply efficiency given by a factor 0.98.
b) For single stage pump, multiply efficiency given by a factor 0.97.
2 The motor efficiency factor of motor ratings not given in the Table 1, 2, 3, 4 and 5 shall be declared by the manufacturer. The motor efficiency factor of motors used with pumpsets suitable for bore sizes
more than 200mm shall be as declared by the manufacturer but it shall be not less than the motor efficiency factor of motors of same rating for 200mm bore size.
3 For overall efficiency of the pumpset, multiply pump efficiency by corresponding motor efficiency factor as given in Table 1, 2, 3, 4 and 5.
4 The efficiency chart includes non-return valve losses.
5 Efficiency of the pumpsets having declared duty points beyond the efficiency lines on the either side may be declared by the manufacturer and applicable tolerance applied. Where the point lies in between
the efficiency lines, the higher value be taken as minimum efficiency.
6 For discharges below 5 litres per second, figure 5 shall be referred

Fig. 4 Minimum Pump Efficiency in Percent for (2-Pole) Submersible Pumpset


(Above 5 and Upto 62 Liters Per Second)
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -

IS 8034 : 2018
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

NOTES
1) The efficiency in figure represents three or more stages:
a) For two stage pump, multiply efficiency given by a factor 0.98.
b) For single stage pump, multiply efficiency given by a factor 0.97.
2) The motor efficiency factor of motor ratings not given in the Table 1, 2, 3, 4 and 5 shall be declared by the manufacturer. The motor
efficiency factor of motors used with pumpsets suitable for bore sizes more than 200 mm shall be as declared by the manufacturer but it
shall be not less than the motor efficiency factor of motors of same rating for 200 mm bore size.
3) For overall efficiency of the pumpset, multiply pump efficiency by corresponding motor efficiency factor as given in Table 1, 2, 3, 4
and 5.
4) The efficiency chart includes non-return valve losses.
5) Efficiency of the pumpsets having declared duty points beyond the efficiency lines on the either side may be declared by the
manufacturer and applicable tolerance applied. Where the point lies in between the efficiency lines, the higher value be taken as
minimum efficiency.
6) For discharges above 5 litres per second, Fig. 4 shall be referred

Fig. 5 Minimum Pump Efficiency in Percent for (2-Pole) Submersible Pumpset


(Up To 5 Litres Per Second)

11.1.4 Submersible motor shall not get overloaded in in column 4 of Tables 1 to 5, at + 10 percent and
the specified operating head range at rated voltage and – 25 percent of the guaranteed duty point head or ± 3 m,
supply frequency. whichever is of lesser range.
11.1.5 The pump shall be capable to give discharge 11.1.6 The tolerance shall apply to guaranteed duty
without overloading the prime mover within the point only.
permissible current limit at rated voltage and supply
frequency as specified in column 4 of Tables 1 to 5, at 11.1.7 Performance at rated voltage and supply
minimum + 10 percent and minimum – 25 percent of frequency is actual performance of the set. This is
the guaranteed duty point head. Below 20 m, the pump better than performance at rated speed, since in the
shall be capable to give discharge without overloading entire operating head range speed of motor is higher
the prime mover within the permissible current limit than rated speed, as motor is running in under loaded
at rated voltage and supply frequency as specified condition.

14
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

11.1.8 The manufacturer shall specify the minimum 11.4.2 The motor efficiency factor of motor ratings not
submergence of pump unit at duty point. given in the Table 1, 2, 3, 4 and 5 shall be as declared by
the manufacturer. The motor efficiency factor of motors
11.2 Head and Discharge used with pumpsets suitable for bore sizes more than
Pump performance shall be declared at the rated 200 mm shall be as declared by the manufacturer but
voltage and rated frequency. Following affinity laws it shall be not less than the motor efficiency factor of
shall be applied for correction of performance at rated motors of same rating for 200 mm bore size.
frequency.
11.4.3 Efficiency of the pumpsets having declared duty
a) Discharge (Q) ∝  f points beyond the efficiency lines on either side may be
b) Head (H) ∝  f  2 declared by the manufacturer and applicable tolerance
c) Power (P) ∝  f  3 applied. Where the point lies in between the efficiency
lines, the higher value is taken as minimum efficiency.
(where, f  = supply frequency)
11.4.4 The efficiency chart includes non-return valve
11.3 Current losses.

11.3.1 The rated current of motor (maximum) as given 11.5 Overall Efficiency
in the tables 1, 2, 3, 4 and 5 for three phase motors and
11.5.1 For arriving at minimum overall efficiency of
single phase motors for applicable motor rating.
the pumpset, refer notes given in Fig.4 and 5.
11.3.2 The rated current of motor (maximum) is given
11.5.2 A superior value of overall efficiency at declared
in the corresponding table for applicable motor rating
duty head per stage and discharge value may be declared
are for preferred rated voltage only. For other voltages,
by the manufacturer, and applicable tolerance shall be
it shall be in inverse proportion to the preferred rated
applied. After applying tolerances, it should not be
voltage.
lesser than minimum overall efficiency requirements.
11.3.3 Manufacturer shall declare the rated current
of the motor less than or equal to the rated current 12 GUARANTEE OF WORKMANSHIP AND
(maximum) of the motor as given in the corresponding MATERIAL
table for applicable motor rating. The pumps shall be guaranteed by the manufacturer
against the defects in material and workmanship under
11.3.4 To arrive at the permissible limit of maximum
normal use and service either for a period of at least 15
current at rated voltage in the operating head range
months from the date of dispatch or 12 months from the
for checking the non-overloading requirement in the
date of commissioning, whichever is earlier.
operating head range of the pumpset, the rated current
of motor (maximum) at rated voltage as given in 13 PERMISSIBLE INACCURACIES IN
the corresponding table for applicable motor rating MEASUREMENTS
multiply by 1.07.
13.1 In all commercial acceptance tests for agricultural
11.3.5 For other voltages, the permissible limit of
pumps, a certain tolerance shall be allowed to the
maximum current in the operating head range shall be
manufacturer on his guarantee to cover the inaccuracies
in inverse proportion to the preferred rated voltage.
of the measurement of volume rate of flow, errors of
11.3.6 In the case of lesser value declaration on the observation and unavoidable errors of the instruments
rated current of motor (maximum) by the manufacturer, employed.
7 percent plus tolerance on the declared rated current
13.2 The permissible inaccuracy in the measurement
of motor (maximum) shall be allowed for arrive the
of various quantities and all pertinent apparatus used
permissible limit of maximum current in the operating
shall be as indicated in IS 11346. However, measuring
head range for checking the Non-overloading
equipment’s with higher accuracy class may also be
requirement in the operating head range.
used.
11.4 Pump Efficiency
14 MARKING AND PARAMETERS TO BE
11.4.1 The efficiency in Fig. 4 and 5 represents for three DECLARED BY THE MANUFACTURER
or more stages of pumps
14.1 A name plate of corrosion-resistant material shall
a) For two stage pump, multiply efficiency given by
be affixed on the pumpset with the following details:
a factor 0.98; and
b) For single stage pump, multiply efficiency given a) Manufacturer’s name or trade-mark, if any;
by a factor 0.97. b) Model;

15
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

c) Serial No.; 6) Tube well capacity at predicted draw-down.


d) Number of stages; g) Description of the well:
e) Bore size, Min; 1) Installation of the pump in:
f) Head, at nominal duty point; i) open well,
g) Discharge, at nominal duty point; ii) tube well,
h) Overall efficiency; iii) open well with a boring, and
j) Motor rating (kW); iv) Others.
k) Rated speed (rpm); 2) Minimum inside diameter of the tubewell or
m) Maximum current (amp); casing pipe.
n) Rated voltage (V); 3) Total depth of open well/deep well.
p) Rated frequency (Hz); 4) Total depth of casing pipe.
q) Category of motor; 5) Static water depth.
r) Connection star, delta, star/delta (for three phase); 6) Well-developed to.... l/min at.... metre draw-
down.
s) Type of duty (whether continuous or not);
h) Site conditions:
t) Delivery size;
1) Height above mean sea level in metres, and
u) Head range for non-overloading requirements;
and 2) Details of quality of water with respect to all
the characteristics as given in 4.
v) Type of motor CSR/CSCR (for single phase).
j) Power supply:
14.2 BIS Certification Marking 1) Type of supply (single-phase/three phase)
The submersible pumpsets may also be marked with 2) Frequency (Hz)
BIS Standard Mark.
i) Voltage (V), and
14.2.1 The use of the Standard Mark is governed by ii) Variation in voltage/frequency.
the provisions of the Bureau of Indian Standards Act, k) Accessories (state whether the following items are
2016 and the Rules and Regulations made there under. required):
The details of the conditions under which the licence
for the use of the Standard Mark may be granted to 1) Sluice valve,
manufacturers or producers, may be obtained from the 2) Reflux valve,
Bureau of Indian Standards. 3) Pressure gauge,
4) Rising main pipe and delivery bend/elbow,
15 INFORMATION TO BE FURNISHED BY
THE PURCHASER 5) Type of installation stages in the entire system,
6) Water level indicator,
When enquiring or ordering pumps to this standard,
the user may furnish the following information to the 7) Voltage stabilizer,
suppliers: 8) Automatic starting and stopping device
a) Name of the purchaser, (optional),
b) Address of the purchaser, 9) Starter — Direct on the line or star-delta or
indicate starting method,
c) Installation site,
10) Voltmeter,
d) Number of pumps required,
11) Ammeter,
e) Spare parts required,
12) Single phasing preventers,
f) Pump operating conditions:
13) Water level guard, and
1) Capacity........l/min, l/s or m3/h.
14) Low voltage protector.
2) Number of poles of motor.
NOTE — Serial no. 6 to 14 may be arranged in a separate
3) Total head, alternatively, sketch of the pipe control panel.
line giving information, such as, static delivery
pipe diameter and length, distance between 16 INFORMATION TO BE FURNISHED BY
point of discharge, pipe fittings and valves THE MANUFACTURER
used, etc., may be given. If purchaser demands, the supplier shall furnish the
4) Total depth of casing pipe. following information while supplying the pumpset to
5) Static water depth. this standard.

16
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

a) Type designation of pump and submersible motor, 5) Maximum current at rated voltage and
b) Details of pump, frequency.
1) Method of lubrication (normally the parts of d) Accessories:
the submersible pumpset are lubricated by 1) Suitable starter,
the pumped liquid itself. If any other type of 2) Main switches,
lubrication is adopted, it shall be indicated;
3) Ammeter and voltmeter,
2) Minimum bore well diameter, in mm;
4) Pressure gauge,
3) Number of stages;
5) Water level indicating relays,
4) Outside diameter of the bowl, the maximum
6) Automatic starting and stopping device,
diameter of the pump fitted with non-return
valve and maximum overall diameter of the 7) Reflux valve and sluice valve, and
pumpset including the cable guard, mm; 8) Erection clamps and special spanners, if any.
5) Discharge.......l/s; e) Additional information to be furnished with the
6) Total head.........m; supply, if required.
7) Speed........rpm; 1) Performance curves:
8) Overall efficiency at duty point...... percent; a) Discharge v/s head curve,
and b) Discharge v/s overall efficiency,
9) Minimum submergence at duty point.......m. c) Discharge v/s current,
c) Details of motor: 2) Instructions for installation and maintenance,
1) Rating.....kW, and
2) Type.......... in accordance with IS 9283, 3) Weight of the pump motor together in kg and
that of cables in kg/m length.
3) Details of power supply,
4) Number of poles of motor, and

17
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

IS 8034 : 2018

ANNEX A
( Clause 2 )

LIST OF REFERRED INDIAN STANDARDS

IS No Title
IS 210 : 1993 Grey iron castings — Specification (  fourth revision)
IS 318 : 1981 Specification for leaded tin bronze ingots and castings (second revision)
IS 694 : 2010 Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and
flexible conductor for rated voltages up to and including 450/750 V code of practice
for construction and testing of tubewells/borewells
IS 2800 Code of practice for construction and testing of tubewells/borewells
Part 1 : 1991 Construction (second revision)
Part 2 : 1979 Testing (first revision)
IS 5120 : 1977 Technical requirements for rotodynamic special purpose pumps (  first revision)
IS 6603 : 2001 Stainless steel bars and flats — Specification (  first revision)
IS 6911 : 1992 Stainless steel plate, sheet and strip — Specification (  first revision)
IS 9283 : 2013 Motors for submersible pumpsets — Specification (  first revision)
IS 10572 : 1983 Methods of sampling for pumps
IS 11346 : 2002 Code of acceptance tests for agricultural and water supply pumps (  first revision)
IS 11723 : 1992 Mechanical vibrations — Balance quality requirements of rigid rotors: Part 1
Determination of permissible residual unbalance (first revision)
IS 14536 : 1998 Selection, installation, operation and maintenance of submersible pumpset — Code
of practice
IS/ISO 1940-1 : 2003 Mechanical vibration — Balance quality requirements for rotors in a constant
(Rigid) state: Part 1 Specifications and verification of balance tolerances
IS 3043 : 1987 Code of practice for earthing
IS/IEC 60034-1 : 2004 Rotating electrical machines: Part 1 Rating and performance
IS/IEC 60034-8 : 2002 Rotating electrical machines: Part 8 Terminal markings and direction of rotation

18
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].
Free Standard provided by BIS via BSB Edge Private Limited to Shibu P Velam kudi paramba -
kozhikode([email protected]) 116.68.127.62 [for non-commercial use only].

Bureau of Indian Standards

BIS is a statutory institution established under the Bureau of Indian Standards Act, 2016 to promote harmonious
development of the activities of standardization, marking and quality certification of goods and attending to
connected matters in the country.

Copyright

BIS has the copyright of all its publications. No part of these publications may be reproduced in any form without
the prior permission in writing of BIS. This does not preclude the free use, in the course of implementing the
standard, of necessary details, such as symbols and sizes, type or grade designations. Enquiries relating to
copyright be addressed to the Director (Publications), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards
should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of
‘BIS Catalogue’ and ‘Standards: Monthly Additions’.
This Indian Standard has been developed from Doc No.: MED 20 (12320).

Amendments Issued Since Publication


Amend No. Date of Issue Text Affected

BUREAU OF INDIAN STANDARDS


Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002
Telephones: 2323 0131, 2323 3375, 2323 9402 Website: www.bis.gov.in
Regional Offices: Telephones
Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg
NEW DELHI 110002 { 2323 7617
2323 3841
Eastern : 1/14 C.I.T. Scheme VII M, V.I.P. Road, Kankurgachi
KOLKATA 700054 { 2337 8499, 2337 8561
2337 8626, 2337 9120
Northern : Plot No. 4-A, Sector 27-B, Madhya Marg
CHANDIGARH 160019 { 265 0206
265 0290
Southern : C.I.T. Campus, IV Cross Road, CHENNAI 600113
{ 2254 1216, 2254 1442
2254 2519, 2254 2315
Western : Manakalaya, E9 MIDC, Marol, Andheri (East)
MUMBAI 400093 { 2832 9295, 2832 7858
2832 7891, 2832 7892
Branches : AHMEDABAD. BENGALURU. BHOPAL. BHUBANESHWAR. COIMBATORE.
DEHRADUN. DURGAPUR. FARIDABAD. GHAZIABAD. GUWAHATI.
HYDERABAD. JAIPUR. JAMMU. JAMSHEDPUR. KOCHI. LUCKNOW.
NAGPUR. PARWANOO. PATNA. PUNE. RAIPUR. RAJKOT. VISAKHAPATNAM.
Published by BIS, New Delhi

You might also like