RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
1 Product Overview
This document describes the 19-inch RAN Compute units for Ericsson Radio Systems.
– Mixed Mode
– Massive-IoT
– 5G Plug ins
– Elastic RAN
– Backhaul cascading
1.2 Purpose
RAN Processor 6647 and RAN Processor 6651 provide switching, traffic management, timing, baseband processing,
and radio interfacing. The RAN Compute units are in the 19-inch format. RAN Processor 6647 has 9 and RAN Processor
6651 has 12 Common Public Radio Interface (CPRI or eCPRI) ports respectively, enabling increased connectivity for
radio units.
1.3 Variants
– RAN Processor 6647 and RAN Processor 6651:
• Version R-state R3C requires the following (or higher) SW releases: 21.Q4.2, 22.Q1.1 and 22.Q2.1.
For information on supported configurations and capacity, see Radio Node Configurations
1.4 Overview
This section provides an overview of the 19-inch RAN Compute units.
2 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
Ge24967A
Ge24956B
The RAN Compute units are self-contained 19-inch units with an easily removable fan tray unit. Each unit can be
installed standalone in any 19-inch rack. enclosure or in an RBS. The units support both horizontal and vertical
installation.
The RAN Compute units facilitate a scalable, modular system with one or more indoor 19-inch baseband units and a
number of external radios.
For information about 19-inch baseband unit placement in an enclosure or an RBS, refer to Enclosure Description or
RBS Description.
AIR / RRU
AIR
Antenna
Optical
Optical cable Radio
cable
Power
cable
Power
RAN Processor
RD
IRU
Ge24958A
Note: Seals that have been implemented by Ericsson must not be broken or removed, as it otherwise voids warranty.
3 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
2 Function Description
The unit has the following functions:
– Timing function
– Loadable software
– IP traffic management
– Radio interface
– Backhaul handling
– External synchronization
4 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
3 Technical Data
3.1 Dimensions
Description Va l u e
Temperature(1) 0 to +55°C
Relative humidity 5–95%
Absolute humidity 1–29 g/m3
Maximum temperature change 0.5°C/min
(1) The long term average temperature is recommended to be around 30 °C or lower. Continuous operation close to upper temperature limit will
negatively impact the product long term reliability
Note: The operating environment of the unit must be a temperature-controlled enclosed location suitable for sensitive
data and telecommunication equipment, with very low levels of airborne particles. For example Network
Telecommunication Facilities or inside an Outside Plant (OSP) cabinet.
Note: The unit cannot be installed in cabinets that do not meet the environmental requirements for operation, for
example cabinets using outside air cooling or not having adequate control of particles, airborne corrosive gases,
and salt mist.
For detailed environmental requirements, see Environmental Specifications - Operational Conditions.
5 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
3.2.2 Vibration
This section describes the unit tolerance to vibrations.
The unit operates reliably during seismic activity as specified by Telcordia GR-63-CORE, EQ4 and the test method IEC
60 068-2-57 Ff.
The unit operates reliably during random and shock vibration as specified by ETSI EN 300 019-2-3.
The unit operates reliably during random vibration as specified by test method IEC 60 068-2-64 Fh.
The unit operates reliably during shock as specified by test method IEC 60 068-2-27 Ea.
Condition Va l u e
Nominal voltage −48 V DC
Operating voltage range −38.0 to −58.5 V DC(1)
Non-destructive range 0 to −60 V DC
(1) During cold startup the supply voltage must be between -46 V DC and -58.5 V DC
Fu s e a n d C i rc u i t B r e a ke r R e c o m m e n d a t i o n s
The external fuse and circuit breaker recommendation for the RAN Compute unit is shown in Table 6.
The recommendations in this section are based on peak power consumption and give no information on power
consumption during normal operation.
The recommended melting fuse type is gG-gL-gD in accordance with IEC 60269-1. Circuit breakers must comply with
at least Curve 3 tripping characteristics in accordance with IEC 60934.
Note: The maximum fuse rating shown below is for general use. Always consider local regulations and situations that
can lower the maximum fuse rating. The maximum fuse rating for a 14 AWG cable is, for example, 15 A in the
US according to NEC.
The Baseband unit itself is rated for 25 A. When installed in Ericsson Enclosures, the fuse ratings have been
dimensioned for the Enclosure environment, and can be different from what is stated in the table.
For detailed information regarding fuse limits for different installation scenarios, see power cables related
specifications in Baseband Connections.
6 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
D C P owe r M i n i m u m Fu s e Ra t i n g f o r Re l i a b l e M ax i m u m Fu s e Ra t i n g ( 3 )
O p e rat ion (2)
RAN Processor 6651 15 A 25 A
RAN Processor 6647 10 A 25 A
(2) The recommended fuse rating corresponds to peak load and depends on the configuration.
(3) This value specifies the maximum fuse rating the unit can withstand. For product safety, the maximum fuse rating must never be exceeded. To
avoid hazardous damage, general fuse dimensioning must consider all external factors, such as local regulations and cable dimensioning.
7 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
4 Hardware Architecture
This section contains an overview of the standard hardware units.
Position Na me of Un its Nu mb er of Un it s
A 19-inch RAN Compute unit 1
B Fan module 1
C Movable Brackets 2
8 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
9 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
(1) For more information about optical indicators, see Indicators, Buttons, and Switches
(2) The 19-inch RAN Compute units have a built-in 10 ms hold-up function.
(3) The unit supports power redundancy. Connect power sources to both power ports. If the power to one port goes down, a failover will occur
automatically to the other power source.
(4) The unit supports 3-wire (DC-I) power feed. It can also support 2-wire (DC-C) power feed by making a jumper connection in the power cable.
Refer to Install 19-Inch Baseband for more information about the power cable pin out, and Power Cables 2- and 3-Wire.
(5) Auto-negotiation not supported for 25G electrical interface (25GBASE-CR)
(6) Supports synchronization over the transport network
(7) IEEE802.3 clause 108
(8) Only supported in 25G link speed
(9) IEEE802.3 clause 74
(10) Baseband has two RI-port groups. For more information on the connections see Radio Node Configurations.
(11) Support connection up to 10.1 Gbps
(12) Depending on the Software Package
(13) PTP support on TN E is only valid at 1 Gbps
(14) Only available when unit is in network loader state
(15) RS-232 interface. Accessed with the LMT splitter cable.
(16) For more information about the LMT interfaces, see Connect Client.
(17) 100 Mbps electrical Ethernet interface.
(18) Compliant with 1PPS 50 Ω phase synchronization measurement interface. Accessed with an adapter.
(19) For more information about the sync test interface, see Manage Network Synchronization.
(20) The optical indicator indicates the status of the LMT B interface.
Remove the protective plugs only where cables are to be connected. Make sure that all connectors that are not
connected have protective plugs.
Each alarm can be configured to be triggered by the following two alarm conditions:
Table 9 External Alarms and Output Characteristics for RAN Processor 6647 and RAN Processor 6651
Ala rm I n p u t P or t De tails C h a ra c te r i s t i c s
Number of alarm input 8
Maximum sensed impedance for a closed loop condition Closed (less than 5 kΩ)
Minimum sensed impedance for an open loop condition Open (greater than 60 kΩ)
Maximum current sourced from port interface 10 mA
Maximum voltage sourced from port interface 18 V
10 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
– UK market requirements, Radio Equipment Regulations 2017 and Radio Equipment Directive 2014/53/EU.
EU
UK
I n te r n a t i o n a l
– IEC 62368-1
EU and UK
– EN 60 529 (IP20)
– EN 62368-1
USA
– UL 62368-1
Kanada
11 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
I n te r n a t i o n a l
– 3GPP TS37.113
EU and UK
USA
Kanada
– ICES-003
I n te r n a t i o n a l
– 3GPP TS37.141
EU and UK
6.1.5 Marking
To show compliance with legal requirements the product is marked with the following labels:
EU
– CE mark
– WEEE symbol
UK
– WEEE symbol
USA
– cETLus
12 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
• This device must accept any interference received, including interference that may cause undesired
operation.”
Kanada
– cETLus
13 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
7 Preventive Maintenance
The product is designed for a technical lifetime of 10 years (24-hour operation).
The following preventive maintenance conditions must be fulfilled to guarantee the availability:
Note: The intervals between maintenance at each unit can vary depending on local environmental conditions.
14 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
8 Spare Parts
The product adheres to the Ericsson Serviceability and Spare Part Strategy.
15 of 16 9/21/2023, 4:11 PM
RAN Compute Description https://cpi.ericsson.net/elex?LI=EN/LZN7605043*
Disclaimer The contents of this document are subject to revision without notice due to continued progress in
methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind
resulting from the use of this document.
Trademarks All trademarks mentioned herein are the property of their respective owners. These are shown in the
document Trademark Information.
16 of 16 9/21/2023, 4:11 PM