USER’S MANUAL
HYBRID SOLAR INVERTER
Infinity HLE-V
3KW~5KW
Appliances
Table of Contents
ABOUT THIS MANUAL................................................................................................1
Purpose...........................................................................................................................................1
Scope..............................................................................................................................................1
SAFETY INSTRUCTIONS............................................................................................
INTRODUCTION........................................................................................................ 2
Features..........................................................................................................................................2
Basic System Architecture.............................................................................................................2
Product Overview..........................................................................................................................3
INSTALLATION......................................................................................................... 4
Unpacking and Inspection..............................................................................................................4
Preparation.....................................................................................................................................4
Mounting the Unit..........................................................................................................................4
Battery Connection........................................................................................................................5
AC Input/ Output Connection........................................................................................................7
PV Connection...............................................................................................................................8
Final Assembly............................................................................................................................10
Communication Connection........................................................................................................10
Dry Contact Signal.......................................................................................................................10
OPERATION.............................................................................................................
11
Power ON/OFF............................................................................................................................11
Operation and Display Panel.......................................................................................................11
LCD Display Icons......................................................................................................................12
LCD Setting.................................................................................................................................14
Fault Reference Code...................................................................................................................20
Warning Indicator........................................................................................................................22
Operating Mode Description.......................................................................................................23
Display Setting.............................................................................................................................25
SPECIFICATIONS ....................................................................................................27
Purpose
This manual describes the assembly, installation, operation and troubleshooting of this unit.
Please read this manual carefully before installations and operations. Keep this manual for future
reference.
Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
(4) Inverter was damaged caused of transport shift, remissness,ect external factor.
(6) Not in accordance with the electrical power supply conditions or operate environment
caused damage.
SAFETY INSTRUCTIONS
WARNING: This chapter contains important safety and operating instructions. Read
and keep this manual for future reference.
1. Before using the unit, read all instructions and cautionary markings on the unit the batteries and
all appropriate sections of this manual.
2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable
batteries. Other types of batteries may burst, causing personal injury and damage.
3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required.
Incorrect re-assembly may result in a risk of electric shock or fire.
4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or
cleaning. Turning off the unit will not reduce this risk.
5. CAUTION --Only qualified personnel can install this device with battery.
7. For optimum operation of this inverter/charger, please follow required spec to select appropriate
cable size. It' s very important to correctly operate this inverter/charger.
8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to
drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals.
Please refer to INSTALLATION section of this manual for the details.
10. Fuses (1 piece of 200A, 58VDC for 3KW,4KW and 5KW) are provided as over-current
protection for the battery supply.
12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC
input short circuits.
13. Warning!! Only qualified service persons are able to service this device. If errors still persist
after following troubleshooting table, please send this inverter/charger back to local dealer or
INTRODUCTION
This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery
charger to offer uninterruptible power support with portable size. Its comprehensive LCD display
offers user-configurable and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different applications.
Features
Configurable input voltage range for home appliances and personal computers via LCD setting
The following illustration shows basic application for this inverter/charger. It also includes
following devices to have a complete running system:
Generator or Utility.
PV modules (option)
Consult with your system integrator for other possible system architectures depending on your
requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-
type appliances such as tube light, fan, refrigerator and air conditioner.
Product Overview
2. Status indicator
3. Charging indicator
4. Fault indicator
5. Function buttons
Downloaded by Mohsin Shahzad ([email protected])
6. Power on/off switch
lOMoARcPSD|39586884
INSTALLATION
Before installation, please inspect the unit. Be sure that nothing inside the package is
damaged. You should have received the following items inside of package:
The unit x 1
User manual x 1
Communication cable x 1
USB cable x 1
Software CD x 1
Preparation
Before connecting all wirings, please take off bottom cover by removing two screws as shown below.
Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC
over-current protector or disconnect device between battery and inverter. It may not be requested to
have a disconnect device in some applications, however, it's still requested to have over-current
protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
Ring terminal:
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use
appropriate cable for battery connection. To reduce risk of injury, please use the
1. Assemble battery ring terminal based on recommended battery cable and terminal size.
2. Connect all battery packs as units requires. It's suggested to connect at least 200Ah capacity
battery for 3KW~5KW model.
3. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure
the bolts are tightened with torque of 2-3 Nm. Make sure polarity at both the battery and the
inverter/charge is correctly connected and ring terminals are tightly screwed to the battery
terminals.
Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal and
the ring terminal. Otherwise, overheating may occur.
AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker
between inverter and AC input power source. This will ensure the inverter can be securely
disconnected during maintenance and fully protected from over current of AC input. The
recommended spec of AC breaker is32A for 3KW,40A for 4KW and 50A for 5KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT-
misconnect input and output connectors.
WARNING! It's very important for system safety and efficient operation to use appropriate cable
for AC input connection. To reduce risk of injury, please use the proper recommended cable size as
below.
2. Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor
N 3mm.
3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal
screws. Be sure to connect PE protective conductor ( ) first.
Ground (yellow-green)
N Neutral (blue)
WARNING:
Be sure to that AC power source is disconnected before attempting to hardwire it to the unit.
4. Then, insert AC output wires according to polarities indicated on terminal block and tighten
terminal screws.
Ground (yellow-green)
N Neutral (blue)
CAUTION: Important
Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may
cause utility short-circuited when these inverters are worked in parallel operation.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because
it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage
occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent
this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay
function before installation. Otherwise, this inverter/charger will trig overload fault and cut off
output to protect your appliance but sometimes it still causes internal damage to the air conditioner.
PV Connection
WARNING! It's very important for system safety and efficient operation to use appropriate cable
for PV module connection. To reduce risk of injury, please use the proper recommended cable size
as below.
PV Module Selection:
1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of
inverter.
2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
3. Max. Power Voltage (Vmpp) of PV modules should be close to best Vmp of inverter or within
Vmp range to get best performance. If one PV module can not meet this requirement, it's
necessary to have several PV modules in series connection. Refer to below table.
The PV charging efficiency is maximized while PV system voltage is close to Best Vmp.
MPPT charger
PWM charger
Final Assembly
After connecting all wirings, please put bottom cover back by screwing two screws as shown below.
Communication Connection
Please use supplied communication cable to connect to inverter and PC. Insert bundled CD into a
computer and follow on-screen instruction to install the monitoring software. For the detailed
software operation, please check user manual of software inside of CD.
There is one dry contact (3A/250VAC) available on the rear panel. It could be used to deliver signal
to external device when battery voltage reaches warning level.
Dry contact
port:
Battery voltage>Setting
value in Program 21 or
Close Open
battery charging reaches
floating stage
Output is
powered from Program Battery voltage<Setting Open Close
Power On
Battery or 01is set as value in Program 20
Solar. SBU, SUB,
Battery voltage>Setting
solar first
value in Program 21 or
Close Open
battery charging reaches
floating stage
OPERATION
Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press On/Off
switch (located on the button of the case) to turn on the unit.
The operation and display panel, shown in below chart, is on the front panel of the inverter. It
includes three indicators, four function keys and a LCD display, indicating the operating status and
input/output power information.
LED Indicator
Function Keys
ENTER Enter setting mode and Confirm the selection in setting mode go to next
selection or exit the reset mode.
Indicate input voltage, input frequency, PV voltage, battery voltage and charger
current.
Indicate output voltage, output frequency, load in VA, load in Watt and
discharging current.
Battery Information
Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode
and charging status in line mode.
<1.717V/cell
1.717V/cell~1.8V/cell
>1.883 V/cell
<1.817V/cell
1.817V/cell~1.9V/cell
>1.983 V/cell
<1.867V/cell
1.867V/cell~1.95V/cell
Load<20% 1.95V/cell~2.033V/cell
>2.033 V/cell
Load Information
Indicates overload.
Mute Operation
LCD Setting
After pressing and holding "ENTER" button for 2 seconds, the unit will enter setting
mode. Press "UP" or "DOWN" button to select setting programs. And then, press
"ENTER" or "MENU" button to confirm the selection and exit.
Setting Programs:
Appliances
(default)
UPS
voltage range GEN When the user uses the device to connect the
generator, select the generator mode.
VDE
overload occurs
in battery
mode.
GEL LEAD
14 Battery type
17 Bulk charging
voltage(C.V voltage) If self-defined is selected in program 14, this program can be set up.
Setting range is from 48.0V to 58.4V for 48Vdc model. Increment of
each click is 0.1V.
18 Floating charging
voltage If self-defined is selected in program 14, this program can be set up,
Setting range is from 48.0V to 58.4V for 48Vdc model. Increment of
each click is 0.1V.
(default)
23 Backlight control
24 Alarm control
After pressing and holding “MENU” button for 6 seconds, the unit will enter reset model. Press
“UP” and “DOWN” button to select programs. And then, press “ENTER” button to exit.
Warning Indicator
63 Battery is over-charged.
64 Low battery
67 Overload
77 Parameter error
Sell state PV energy is sold PV energy power is larger than inverter power
back to grid.
Note:
Match load state PV energy is charger PV energy power is larger than inverter power
into the battery or
Note: DC power
convertered by the
produced from your
inverter to the AC
solar array is
load
converted by the
inverter into AC
power, which is then PV energy power is smaller than inverter power
sent to your main
electrical panel to be
used by your
household appliances.
Any excess power
generated is not sold
back to the grid, but
stored in battery.
PV is off
Off-Grid state The inverter will Inverter power loads from PV energy.
provide output
power from battery
and PV power.
Display Setting
The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The
selectable information is switched as below order: battery voltage, battery current, inverter voltage,
inverter current,grid voltage, grid current, load in Watt, load in VA, grid frequency, inverter
frequency, PV voltage, PV charging power, PV charging output voltage, PV charging current.
Load in Watt
SPECIFICATIONS
186Vac±7V(VDE)
196Vac±7V(VDE)
47.5HZ±0.05HZ(VDE)
47.5HZ±0.05HZ(VDE)
51.5HZ±0.05HZ(VDE)
50.05HZ±0.05HZ(VDE)
@load<20% 44.0Vdc
@ 20%≤load<50% 42.8Vdc
@load≥50% 40.4Vdc
@load<20% 46.0Vdc
@ 20%≤load<50% 44.8Vdc
@load≥50% 42.4Vdc
@load<20% 42.0Vdc
@ 20%≤load<50% 40.8Vdc
@load≥50% 38.4Vdc
4-Step(LI)
MPPT charger
PWM charger
4-Step(LI)
Lithium battery
Safety Certification CE
TROUBLE SHOOTING
Problem LCD/LED/Buzzer Explanation / Possible What to do
cause
Unit shuts LCD/LEDs and The battery voltage is too 1. Re-charge battery.
down buzzer will be active low
2. Replace battery.
automatically for 3 seconds and
( < 1.91V/Cell)
during startup then complete off.
process.
No response No indication. 1. The battery voltage is 1. Check if batteries the wiring are
after power on. far too low. (<1.4V/Cell) connected and well.
Mains exist but Input voltage is Input protector is tripped Check if AC breaker is tripped and AC
the unit works displayed as 0 on the wiring is connected well.
in battery LCD and green LED
mode. is flashing.
When the unit LCD display and Battery is disconnected. Check if battery wires are connected
is turned on, LEDs are flashing well.
internal relay is
switched on
and off
repeatedly.
Fault code 05 Output short circuited. Check if wiring is connected well and
remove abnormal load.
Fault code 02 Internal temperature of Check whether the air flow of the unit
inverter component is is blocked or whether the ambient
over 90℃. temperature is too high.
Buzzer beeps
Fault code 03 Battery is over-charged. Return to repair center.
continuously
and red LED is The battery voltage is too Check if spec and quantity of batteries
on. high. are meet requirements.
Fault code 06/58 Output abnormal (Inverter 1. Reduce the connected load.
voltage below than
2. Return to repair center
202Vac or is higher than
253Vac)
Fault code 51 Over current or surge Restart the unit, if the error happens
again, please return to repair center.
Fault code 52 Bus voltage is too low
Fault code 56 Battery is not connected If the battery is connected well, please
well or fuse is burnt. return to repair center.
2400 91 219
2700 71 174
3000 63 155
2400 95 227
2800 81 176
3200 62 140
3600 55 125
4000 50 112
3000 76 182
3500 65 141
4000 50 112
4500 44 100
5000 40 90
Note: Backup time depends on the quality of the battery, age of battery and type of battery.
USER’S MANUAL
HYBRID SOLAR INVERTER
Infinity
HLE - V