Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

MAR2 LED

Linear LED lighting for


hazardous locations

Classifications
∞ Class I, Division 2, Groups A, B, C & D
∞ UL 844 Hazardous Locations
∞ UL 1598A Marine Outside Type
∞ UL 1598 Wet Locations
∞ UL 8750 LED Safety
∞ CSA C22.2 #250.0-08
∞ CSA C22.2 #137-M1981
∞ NEMA 4X
∞ IP66
∞ 55°C Ambient Temperature
∞ Tested to LM 79 & LM 80

availinfra.com/rig-a-lite

8500 Hansen Road,


Houston, TX 77075
(713) 943-0340
MAR2 LED
Linear LED lighting for hazardous locations

Key Features
1 Heavy-duty .094” thick extruded housing

2 Permanent safety cable attachment points


4
2
3 Two ¾” NPT conduit hubs

4 360° mounting flexibility 3


7
5 Field-replaceable LED circuit boards
and drivers with quick disconnects

6 Toolless entry via twist-lock latches


5
7 Watershed design

Additional Features Standard Materials


∞ Offset mounting bracket enables flush mounting Body:
∞ Dimmable driver 5052-H32 Aluminum (less than .4% copper content)

∞ Optional pre-wired feed-through Gaskets:


∞ Low-profile design One-piece Silicone

∞ 4 kV surge protection (10kV option available) Lens:


∞ 5-year warranty Acrylic
Hubs (2):
A361 Aluminum (less than .4% copper content)
Latches:
Stainless Steel
Hardware:
Stainless Steel

availinfra.com/rig-a-lite

8500 Hansen Road,


Houston, TX 77075
(713) 943-0340
MAR2 LED
Linear LED lighting for hazardous locations

Catalog Number Logic

MAR2 07 - L2 - 4 - U - XX
1 2 3 4 5 6

1 3 6
BASIC LUMINAIRE LAMP TYPE OPTIONS1
MAR2 LED L2 = LED TW = End Mounting/Thru Wire Cable
Class I, Division 2, Groups A, B, C & D Installations Only
UL 844 Hazardous Locations 4 F = Fuse Block2
UL 1598 Wet Locations NOMINAL FIXTURE LENGTH TM = Tempered Glass
UL 1598A Marine Outside Type 2 = Two Foot EB = Eye Bolt Only
UL 8750 LED 4 = Four Foot SP = Increased Surge Protection (10 kV)
CSA C22.2 #137 30 = 3000K CCT
CSA C22.2 #213 5 35 = 3500K CCT
55°C Ambient Temperature VOLTAGE/FREQUENCY 50 = 5000K CCT
U = 120 - 277 50/60HZ
2 A = 120V 60HZ²
LAMP CURRENT/LAMP WATTAGE 1 Mounting Hardware not included. Please see
B = 220 - 240V 50/60HZ² accessories for mounting selections.
06 = 56 Watt (2 ft.) C = 277V 60HZ²
2 Specify voltage when option F is needed. When
07 = 74 Watt (4 ft.) option F is selected, one fuse is provided for 120
and 277V. Two fuses are provided for 220-240V.
Fuse option not available for marine listed fixtures,
or for fixtures listed for use in Canada.

Catalog logic is for explaining catalog number


structure only. Not all combinations are possible;
consult factory for catalog numbers not listed
in charts.

Certification Guide
Class I, Div. 2, Supply Wire
Total Lumen Ambient
Model Length Wattage Operating Voltage CRI CCT Group Suitable Hub Size
Lumens per Watt Temperature
A, B, C & D Temp., °C

MAR206L22U 2 ft 56W 120V - 277V 50/60 Hz 5476 98 85 4062 -20°C < Tamb < 55°C T6 90°C 3/4 in. NPT
MAR207L24U 4 ft 74W 120V - 277V 50/60 Hz 7660 103 82 4071 -20°C < Tamb < 55°C T6 90°C 3/4 in. NPT

availinfra.com/rig-a-lite

8500 Hansen Road,


Houston, TX 77075
(713) 943-0340
MAR2 LED
Linear LED lighting for hazardous locations

MAR207L24U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance 80 50 10 Deg. Parl. 22.5 45 67.5 Norm
rcc
% Wall Reflectance 0 2760 2760 2760 2760 2760
50 30 10 50 30 10 50 30 10
rw
Room Cavity Ratio 5 2680 2666 2675 2676 2669
Effective Floor Cavity Reflectance 20%
RCR
25 2513 2495 2516 2522 2519
0 119 119 119 111 111 111 102 102 102
1 106 102 98 99 96 94 92 90 88 35 2261 2248 2286 2295 2285
2 93 86 81 87 82 78 81 78 75 45 1925 1921 1960 1938 1321
3 82 74 68 77 71 66 72 67 64
4 72 64 57 69 62 56 64 59 55 55 1495 1516 1511 1459 1444
5 65 56 49 61 54 49 58 52 48 65 978 1004 953 941 928
6 58 49 43 55 48 42 52 46 42
7 53 44 38 50 43 38 48 42 37 75 409 399 344 17 15
8 48 40 34 46 39 33 44 38 33 85 34 5 5 4 4
9 44 36 30 42 35 30 40 34 30
10 41 33 27 39 32 27 37 31 27 90 0 0 0 0 0

MAR206L22U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance 80 50 10 Deg. Parl. 22.5 45 67.5 Norm
rcc
% Wall Reflectance 0 2068 2068 2068 2068 2068
50 30 10 50 30 10 50 30 10
rw
Room Cavity Ratio 15 1999 1996 1995 1998 2002
Effective Floor Cavity Reflectance 20%
RCR
25 1962 1834 1867 1869 1876
0 119 119 119 111 111 111 102 102 102
1 106 102 99 99 97 94 92 90 89 35 1661 1666 1673 1669 1669
2 93 87 82 88 83 79 82 78 75 45 1396 1405 1407 1384 1379
3 82 75 69 78 72 67 73 68 65
4 73 65 58 69 66 57 65 60 56 55 1068 1087 1063 1052 1051
5 65 57 50 62 55 50 59 53 49 65 677 691 682 362 348
6 59 50 44 56 49 44 53 47 43
7 53 45 39 51 44 39 48 43 38 75 267 270 142 127 29
8 49 40 35 47 40 34 44 38 34 85 15 3 4 4 4
9 45 37 31 43 36 31 41 35 31
10 41 34 28 40 33 28 38 32 28 90 0 0 0 0 0

availinfra.com/rig-a-lite

8500 Hansen Road,


Houston, TX 77075
(713) 943-0340
MAR2 LED
Linear LED lighting for hazardous locations

Fixture Dimensions (inches)

Dimensions (inches) Shipping Volume


MAR 2 Series Boxed Weight
A B C D (Boxed Fixtures)

4 ft. Models 52.13 7.38 6.19 1.81 36 lbs. 2.0 cu. ft.
2 ft. Models 28.13 7.38 6.19 1.81 26 lbs. 1.0 cu. ft.

Accessories
Straight Mounting Kit Offset Mounting Kit
Catalog Number: Catalog Number:
53033 53032
Shipping Weight: Shipping Weight:
5 lbs. 5 lbs.

Safety Cable Straight Brackets


Catalog Number: 2 Required
10128R
Catalog Number:
Shipping Weight: 26364
1 lb
Shipping Weight:
2 lbs.

Offset Brackets
2 Required
Catalog Number:
26348
Shipping Weight:
2 lbs.

availinfra.com/rig-a-lite

8500 Hansen Road,


Houston, TX 77075
(713) 943-0340 © 2022 Avail Infrastructure Solutions 11/2022 GDI