EXCELL NHP/ T

ELECTROSURGICAL UNITS FOR


MONOPOLAR AND BIPOLAR USE
WITH 7.0” TOUCH-SCREEN

A new step AheAd


to the future

ISO 9001 IT - 1231 ISO 13485


9120.ALSA 9124.ALS2 0051
The units EXCELL NHP/T series are provided with all the technical features, and the
monopolar and bipolar currents needed to perform the most advanced electrosurgery
All models are provided with 10 currents for the monopolar cutting
Pure cut without coagulating effect.
Pure Cut
For open or laparoscopic surgery and for under liquid endoscopy (TURP, TURV).
Cut blended with a medium coagulating effect.
Blend Cut 1
For open or laparoscopic surgery and for under liquid endoscopy (TURP, TURV).
Cut blended with a very high coagulating effect.
Blend Cut 2
For open or laparoscopic surgery.
Pulsed pure cut without coagulating effect.
Pure Cut Pulsed
For open or laparoscopic surgery.
Pulsed cut blended with a medium coagulating effect.
Blend Cut Pulsed
For open or laparoscopic surgery.
“Constant voltage” delicate pure cut without coagulating effect.
Auto Pure Cut Micro
For open or laparoscopic surgery and for under liquid endoscopy (TURP, TURV).
“Constant voltage” delicate cut blended with a medium coagulating effect.
Auto Blend Cut Micro
For open or laparoscopic surgery and for under liquid endoscopy (TURP, TURV).
“Constant voltage” pure cut, without coagulating effect, for flexible endoscopy.
Auto Papillo Pure Cut
With four modes of delivery: continuous and pulsed (slow, medium, fast).
“Constant voltage” cut, blended with a medium coagulating effect, for flexible endoscopy.
Auto Polipo Blend Cut
With four modes of delivery: continuous and pulsed (slow, medium, fast).
“Constant voltage” cut with alternating phases of cutting and blended cut, for flexible endoscopy.
Auto EndoCut With four modes of delivery: 90% Coagulation and 10% Cut, 80% Coagulation and 20% Cut, 75% Coagulation and
25% Cut, 50% Coagulation and 50% Cut.
All models are provided with 5 currents for the monopolar coagulation
High voltage, contact free coagulation.
Fulg Forced Coag
For open or laparoscopic surgery, for under liquid endoscopy (TURP, TURV) and for flexible endoscopy.
Very high voltage, contact free coagulation.
Spray Coag
For open or laparoscopic surgery, for under liquid endoscopy (TURP, TURV) and for flexible endoscopy.
Pulsed Spray Coag Identical to the Spray coag current, but pulsed and more delicate.
Medium voltage, contact coagulation.
Pin Point Contact Coag
For open or laparoscopic surgery, for under liquid endoscopy (TURP, TURV) and for flexible endoscopy.
Delicate, low voltage coagulation.
Soft Micro Coag
For open or laparoscopic surgery.
The models NHP/TA-400 and NHP/TA-200 are provided with 2 currents for the Argon coagulation
Very fast and efficacious coagulation (Spray Coag current enhanced by the Argon gas).
Standard
For open or laparoscopic surgery and for flexible endoscopy.
Identical to the Standard current, but more delicate.
Pulsed
(Pulsed Spray Coag current enhanced by the Argon gas).
All models are provided with 4 currents for the bipolar cutting
Standard Bicut Cut for open or laparoscopic surgery.
Blend Bicut Cut blended with a very high coagulating effect (Coagulation = 95%) for open or laparoscopic surgery.
Cut for endoscopy in saline (TURPis, TURVis) with two modes of delivery: continuous and pulsed.
Saline Uro-Gyn Cut For urology and gynaecology.
The continuous delivery is suitable to perform the vaporization.
Cut for arthroscopy in saline with two modes of delivery: continuous and pulsed.
Saline Arthro Cut For arthroscopy.
The continuous delivery is suitable to perform the vaporization.
All models are provided with 3 currents for the bipolar coagulation and 2 currents for the bipolar vessel sealing
Very precise and delicate coagulation.
Soft Micro Bicoag
For open or laparoscopic surgery, for endoscopy in saline (TURPis, TURVis) and for flexible endoscopy.
Fast coagulation.
Forced Macro Bicoag
For open or laparoscopic surgery.
Identical to the Soft Micro Bicoag, but with Impedance sensing automatic activation/deactivation.
Auto Soft Micro Bicoag It is not suitable for the endoscopy in saline.
Activation with delay adjustable from 0 to 5 seconds and deactivation with bitonal, grave, acoustic signal.
Current to coagulate/seal vessels up to 8 mm in open and laparoscopic surgery.
Sealing
Activation with pedal and automatic Impedance sensing deactivation with bitonal, acute, acoustic signal.
Identical to the Sealing, but with Impedance sensing automatic activation/deactivation.
Auto Sealing It is not suitable for the endoscopy in saline.
Activation with delay adjustable from 0 to 5 seconds and deactivation with bitonal, grave, acoustic signal.
Technical features of all models
HF generator Meets IEC 60601-1 and IEC 60601-2-2 (Latest editions). Supply section “switching” type.
EMC compatibility Meets IEC 60601-1-2 (Latest edition).
EC Classification and approval Class IIB according to 93/42/CEE (and its revised version) – Certificate nr. 187/MDD (IMQ 0051).
ALSA quality system Meets ISO 9001 and ISO 13485 (Latest editions). Certificates 9120.ALSA and 9124.ALS2 (IMQ 0051).
Classification according to Class I, CF type with the following typical low frequency leakage currents (all cables tied together):
IEC 60601-1 On the patient: 4µA = 0,004mA / Into the enclosure: 1µA = 0,001mA / To earth: 30µA = 0,03mA.
Output circuit according to FLOATING (Isolated at high and low frequencies) and protected against the use of the defibrillator.
IEC 60601-2-2 Typical HF leakage currents measured at the unit: Monopolar currents = 90mA, Bipolar currents = 60mA.
Working frequency Monopolar and bipolar currents: 440kHz ± 5%.
Computerized MASTER/SLAVE SYSTEM
• It performs a Main Auto-check at the switching ON (repeated every 30 minutes of operation) and the continuous
Standard Auto-check during use.
Functioning control
• It stops the power activation in case of hardware/software failures, mistakes of use, an anomalous power delivery,
and it signals them by acoustic and visual Error Codes.
• It memorizes all Error Codes to help the check and the technical assistance.
Computerized self-adjustment with PER (Power Efficiency Rating > 98%) according to the impedances of tissues
(Feed-back in real time - 7000 times/sec) by two different systems:
• ADC System – Dynamic self-adjustment with constant power
Self-adjusting of
The powers have a progressive setting (Micro and Macro setting with steps from 0,1 to 10W).
output powers
Monopolar currents (from 1 to 10W), Bipolar currents (from 0,1W to 5W).
• APC System - Fully automatic control
The powers have a setting with 10 effects (the unit shows, for each effect, the maximum delivered power).
Control of the HF
By a specific computerized circuit with alarms.
leakage currents
Memorization of programs 100 programs identifiable by number and text (Surgical use or Name of the surgeon).
All models allow the following use of the monopolar and bipolar accessories:
• One/two either hand-switched or foot-switched monopolar pencils or instruments.
Two monopolar pencils can be used simultaneously according to IEC 60601-2-2.
Usable pencils or instruments • One/two bipolar instruments by foot-switch activation (When selecting the Auto Soft Micro Bicoag or the Auto
Sealing currents, an instrument is usable by the Impedance sensing automatic activation/deactivation).
The models TA-400 and TA-200 allow, when the Argon section is ON, the use also of the following:
• One hand-switched or foot-switched pencil/instrument for the Argon enhanced electro-surgery.
The unit can be used by either one or two waterproof (IPN8) twin foot-switches.
• Only with one twin foot-switch (DS/Esw or DS/Eswl, large model for the use in endoscopy) with a
Twin foot-switches Foot-selector to activate either the monopolar or the bipolar currents.
• Only with one twin foot-switch (DS/B) to activate the bipolar currents only.
• With both twin foot-switches, one to activate the monopolar currents and one to activate the bipolar ones.
NPCC System with double circuit: Contact quality monitor and Continuity monitor with four progressive alarm
lights and stop of the power delivery. The circuit operates as follows:
Control circuit of the
• It checks all kinds of neutral electrode, both “split” double area and “non split” single area.
neutral electrode
• It has two modes of use: Large electrodes for adults and Small electrodes for paediatrics and new-born.
• It allows the use of cables with both European “Ø 6,35mm” and USA “2 pins” connectors.
They meet IEC 60601-2-2 (Latest edition).
Luminous and acoustic Lights: Cutting = yellow, Coagulation = blue, Alarms and Error codes = red
signals of activation and Activation sounds: Continuous (acute for the cut and grave for the coagulation, with level adjustable from 45 to
alarm 65dB), including a bitonal sound to indicate the power deactivation when using the currents:
Auto Soft Micro Bicoag, Sealing and Auto Sealing. Alarm sound: Intermittent (High >65dB and not adjustable).
Mains supply and
100 / 230V ± 10% ~ 50/60Hz (Consumption: Max. 3,6A = 828VA, Standby 0,4A = 92VA).
consumption, Mains switch,
Bipolar switch (green), Two fuses 8A, Standby mode selectable on the touch-screen.
Fuses and Standby
Equipotential connection Standard DIN 42801 plug.
Enclosure, Cooling Metal painted case, protected against the spilling of liquids according to IEC 60601-2-2. Cooling by convection (No fan).
Software updating and
Updating by a serial port connected to a PC, calibration on-site.
calibration
Dimensions and weight (LxWxH) NHP/T-400 and T-200: 38x35x19cm - 10Kg – NHP/TA-400 and TA-200: 38x38x19cm - 10,5Kg.
Technical features of the Argon gas section (Models TA-400 and TA-200 only)
Gas (Supply) By 1 or 2 cylinders (5lt) or by centralized supply with max pressure of 4,5 atm.
Gas (Antibacterial protection) Antibacterial filter on the gas output.
Gas (Working pressure and Flow) Pressure: 2 atm. Flow: Max 15lt/min, adjustable from 1 to 15 lt/min and self-adjusted.
By the main Auto-check system of the unit and Pressure Safety System.
Gas (Pressure, Consumption) It blocks the usability of the Argon section either if the gas is absent/not sufficient or its pressure is too high, by
informing the users through alarms and Error Codes. The system includes a pressure reducer and a safety valve.
EXCELL NHP/T-400 and EXCELL NHP/TA-400 – THE CURRENTS
MONOPOLAR CUTTING
Pure Cut Blend Cut 1 Blend Cut 2 Pure Cut Blend Cut Auto Pure Auto Blend Auto Papillo Auto Polipo Auto
Pulsed Pulsed Cut Micro Cut Micro Pure Cut Blend Cut Endocut
Max Output Power 400 W 300 W 250 W 400 W 250 W 300 W 300 W 300 W 300 W 300 W
Rated load 400 Ω 400 Ω 400 Ω 400 Ω 400 Ω 300 Ω 300 Ω 300 Ω 300 Ω 300 Ω
Vpp 2550 3390 3330 2640 3330 1137 1500 1140 1490 1670
Crest factor 1,46 1,94 2,29 2 3,2 1,5 1,98 1,5 1,98
Modulation 0 17 kHz 17 kHz 3 Hz 50 Hz 0 17 kHz 0 17 kHz -
Duty Cycle 100% 95% 65% 50% 50% 100% 90% 100% 95%
Power setting Progressive with steps from 1 to 10 W 10 Effects
Power control ADC System - Dynamic self-adjusting with constant power APC System - Totally self-adjusting with constant voltage
MONOPOLAR COAGULATION
Fulg Forced Coag Spray Coag Pin Point Contact Coag Pulsed Spray Coag Soft Micro Coag

Max Output Power 150 W 200 W 300 W 200 W 280 W


Rated load 300 Ω 700 Ω 400 Ω 700 Ω 300 Ω
Vpp 4500 7750 3700 7850 3300
Crest factor 6,45 7,75 2,2 11,54 2,16
Modulation 60 kHz 30 kHz 17 kHz 3 Hz 17 kHz
Duty Cycle 18% 7% 85% 50% 75%
Power setting Progressive with steps from 1 to 10 W 10 Effects
Power control ADC System - Dynamic self-adjusting with constant power APC System - Totally self-adjusting with constant voltage
ARGON PLASMA COAGULATION (Model NHP/TA-400 only)
Spray Coag + Gas Argon Pulsed Spray Coag + Gas Argon

Max Output Power 200 W 200 W


Rated load 700 Ω 700 Ω
Vpp 7750 7850
Crest factor 7,75 11,54
Modulation 30 kHz 3 Hz
Duty Cycle 7% 50%
Power setting Progressive with steps from 1 to 10 W
Gas setting From 1 to 15 Lt/min
Power control ADC System – Dynamic self-adjusting with constant power
BIPOLAR CUTTING
Saline Uro-Gyn Cut Saline Arthro Cut Standard Bicut Blend Bicut

Max Output Power 350 W 230 W 200 W 160 W


Rated load 350 Ω 350 Ω 300 Ω 200 Ω
Vpp 1070 1070 1070 740
Crest factor 1,5 1,5 1,5 1,57
Modulation 0 0 0 17 kHz
Duty Cycle 100% 100% 100% 95%
Power setting 10 Effects Progressive with steps from 0,1 to 5 W
Power control ADC System - Dynamic self-adjusting with constant power
BIPOLAR COAGULATION AND VESSEL SEALING
Soft Micro Bicoag Auto Soft Micro Sealing Auto Sealing Forced Macro Bicoag
Bicoag
Max Output Power 140 W 140 W 320 W 320 W 200 W
Rated load 100 Ω 100 Ω 50 Ω 50 Ω 100 Ω
Vpp 460 460 780 780 550
Crest factor 1,56 1,56 2,47 2,47 1,6
Modulation 0 0 0 0 0
Duty Cycle 100% 100% 100% 100% 100%
Power setting Progressive with steps from 0,1 to 5 W 10 Effects Progressive with steps from 0,1 to 5 W
Power control APC System - Totally self-adjusting with constant voltage ADC System - Dynamic self-adjusting with constant power
EXCELL NHP/T-200 and EXCELL NHP/TA-200 – THE CURRENTS
MONOPOLAR CUTTING
Pure Cut Blend Cut 1 Blend Cut 2 Pure Cut Blend Cut Auto Pure Auto Blend Auto Papillo Auto Polipo Auto
Pulsed Pulsed Cut Micro Cut Micro Pure Cut Blend Cut Endocut
Max Output Power 200 W 200 W 200 W 200 W 200 W 200 W 200 W 200 W 200 W 200 W
Rated load 400 Ω 400 Ω 400 Ω 400 Ω 400 Ω 300 Ω 300 Ω 300 Ω 300 Ω 300 Ω
Vpp 2550 3390 3330 2640 3330 1137 1500 1140 1490 1670
Crest factor 1,46 1,94 2,29 2 3,2 1,5 1,98 1,5 1,98
Modulation 0 17 kHz 17 kHz 3 Hz 50 Hz 0 17 kHz 0 17 kHz -
Duty Cycle 100% 95% 65% 50% 50% 100% 90% 100% 95%
Power setting Progressive with steps from 1 to 10 W 10 Effects
Power control ADC System – Dynamic self-adjusting with constant power APC System - Totally self-adjusting with constant voltage
MONOPOLAR COAGULATION
Fulg Forced Coag Spray Coag Pin Point Contact Coag Pulsed Spray Coag Soft Micro Coag

Max Output Power 150 W 200 W 200 W 200 W 200 W


Rated load 300 Ω 700 Ω 400 Ω 700 Ω 300 Ω
Vpp 4500 7750 3700 7850 2875
Crest factor 6,4 7,75 2,2 11,54 2,1
Modulation 60 kHz 30 kHz 17 kHz 3 Hz 17 kHz
Duty Cycle 18% 7% 85% 50% 75%
Power setting Progressive with steps from 1 to 10 W 10 Effects
Power control ADC System - Dynamic self-adjusting with constant power APC System - Totally self-adjusting with constant voltage
ARGON PLASMA COAGULATION (Model NHP/TA-200 only)
Spray Coag + Gas Argon Pulsed Spray Coag + Gas Argon

Max Output Power 200 W 200 W


Rated load 700 Ω 700 Ω
Vpp 7750 7850
Crest factor 7,75 11,54
Modulation 30 kHz 3 Hz
Duty Cycle 7% 50%
Power setting Progressive with steps from 1 to 10 W
Gas setting From 1 to 15 Lt/min
Power control ADC System - Dynamic self-adjusting with constant power
BIPOLAR CUTTING
Saline Uro-Gyn Cut Saline Arthro Cut Standard Bicut Blend Bicut

Max Output Power 350 W 230 W 200 W 160 W


Rated load 350 Ω 350 Ω 300 Ω 200 Ω
Vpp 1070 1070 1070 740
Crest factor 1,5 1,5 1,5 1,57
Modulation 0 0 0 17 kHz
Duty Cycle 100% 100% 100% 95%
Power setting 10 Effects Progressive with steps from 0,1 to 5 W
Power control ADC System – Dynamic self-adjusting with constant power
BIPOLAR COAGULATION AND VESSEL SEALING
Soft Micro Bicoag Auto Soft Micro Sealing Auto Sealing Forced Macro Bicoag
Bicoag
Max Output Power 140 W 140 W 320 W 320 W 200 W
Rated load 100 Ω 100 Ω 50 Ω 50 Ω 100 Ω
Vpp 460 460 780 780 550
Crest factor 1,56 1,56 2,47 2,47 1,6
Modulation 0 0 0 0 0
Duty Cycle 100% 100% 100% 100% 100%
Power setting Progressive with steps from 0,1 to 5 W 10 Effects Progressive with steps from 0,1 to 5 W
Power control APC System - Totally self-adjusting with constant voltage ADC System - Dynamic self-adjusting with constant power
NHP/T-REV A - Edizione 02-2018
EXCELL NHP/T-400
with footswitch DS/Esw

EXCELL NHP/T-400
with footswitch DS/Eswl

alsa apparecchi medicali s.r.l.

Via C. Bonazzi, 16
40013 CASTEL MAGGIORE (BO) - ITALY
Tel. +39 051 70 01 01 (r.a.) Fax +39 051 70 21 82
www.alsamed.com
[email protected]