Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645

1
School of Information Science and Technology, North China University of Technology, Beijing 100144, China
2
Advanced Integrated Circuits R&D Center, Institute of Microelectronic of the Chinese Academy of Sciences, Beijing 100029, China
3
State Key Laboratory of Advanced Materials for Smart Sensing, General Research Institute for Nonferrous Metals, Beijing 101402, China
*
Authors to whom correspondence should be addressed.
Biosensors 2024, 14(10), 461; https://doi.org/10.3390/bios14100461
Submission received: 11 September 2024 / Accepted: 19 September 2024 / Published: 26 September 2024
(This article belongs to the Special Issue Biosensors Based on Transistors)

1. Errors in Figure and Table

In the original publication [1], there was a mistake in Figure 7b as published. Figure 7b contained a human error. When creating the figure, due to the similarity with the other figures, we chose the wrong one by mistake. The correct version of Figure 7 appears below.
Correspondingly, there was a mistake in Table 1. The LOD of this work should be 0.2529 ag/mL. The correct version of Table 1 appears below.

2. Text Correction

There were some textual errors related to Figure 7b in the original publication.
There was an error in the Abstract Section, “in the range of Cys-C concentration from 1 ag/mL to 10 pg/mL”, in which “10 pg/mL” is wrong.
A correction has been made to the Abstract Section as follows:
“in the range of Cys-C concentration from 1 ag/mL to 1 ng/mL”.
There was an error in the Introduction Section, “The detection limit of Cys-C solution using SiNW FET biosensor is as low as 0.43 ag/mL”, in which “0.43 ag/mL” is wrong.
A correction has been made to the Introduction Section, paragraph 4, as follows:
“The detection limit of Cys-C solution using SiNW FET biosensor is as low as 0.25 ag/mL”.
There was an error in the Results and Discussion Section, “the linear regression equation after calibration and fitting is y = −1.20982 − 0.45073 × x and R2 = 0.999509, where x is the logarithm of Cys-C concentration, and the detection limit of Cys-C was obtained through linear fitting, with LOD = 0.43341 ag/mL. The average sensitivity to Vth change is 0.41 V/dec.”, in which “y = −1.20982 − 0.45073 × x and R2 = 0.999509”, “LOD = 0.43341 ag/mL” and “Vth change is 0.41 V/dec” is wrong.
A correction has been made to Results and Discussion Section, subsection 3.3, Detection of Cys-C and Sensitivity, paragraph 2, as follows:
“the linear regression equation after calibration and fitting is y = −1.27318 − 0.42954 × x, R2 = 0.98734, where x is the logarithm of Cys-C concentration, and the detection limit of Cys-C was obtained through linear fitting, with LOD = 0.2529 ag/mL. The average sensitivity to Vth change is 0.42 V/dec”.
There was an error in the Conclusions Section, “the detection limit fitted is 0.43 ag/mL”, in which “0.43 ag/mL” is wrong.
A correction has been made to the Conclusions Section as follows:
“the detection limit fitted is 0.25 ag/mL”.
The authors apologize for any inconvenience caused and state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.

Reference

  1. Hu, J.; Li, Y.; Zhang, X.; Wang, Y.; Zhang, J.; Yan, J.; Li, J.; Zhang, Z.; Yin, H.; Wei, Q.; et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. [Google Scholar] [CrossRef] [PubMed]
Figure 7. The electrical response of the SiNW FET biosensor to different concentrations of Cys-C. (a) Transfer curves of the SiNW FET biosensor interacting with varying concentrations of Cys-C (the red frame indicates the change in the curve around the sub-threshold region and is shown enlarged), (b) the Vths of the SiNW FET biosensor in a series of Cys-C concentrations, (c) the real−time response of the Cys-C solution with different concentrations, and (d) the relationship between the steady−state drain current and the concentration of Cys-C.
Figure 7. The electrical response of the SiNW FET biosensor to different concentrations of Cys-C. (a) Transfer curves of the SiNW FET biosensor interacting with varying concentrations of Cys-C (the red frame indicates the change in the curve around the sub-threshold region and is shown enlarged), (b) the Vths of the SiNW FET biosensor in a series of Cys-C concentrations, (c) the real−time response of the Cys-C solution with different concentrations, and (d) the relationship between the steady−state drain current and the concentration of Cys-C.
Biosensors 14 00461 g001
Table 1. Biosensors and immunosensors for detection of Cys-C.
Table 1. Biosensors and immunosensors for detection of Cys-C.
MethodMaterialLinear Range (LOD)Reference
Differential pulse
Voltammetry (DPV)
Au@Fe3O40.01 pg/mL~30 ng/mL (3 fg/mL)Yang et al., 2016 [16]
Photocurrent responseTiO2 nanotubes0.72 pM~3.6 nM
(0.14 pM)
Mi et al., 2016 [17]
Square wave voltammetry (SWV)Prepared poly(thionine)-Au100 ng/mL~10 fg/mL (4.6 fg/mL)Wang et al., 2017 [40]
Cyclic voltammetry and differential pulse voltammetryMultiwalled carbon nanotube (MWCNT)0.6~6.6 ng/mL
(0.58 pg/mL)
Desai et al., 2018 [18]
Linear sweep voltammetry (LSV)AuNPs10~100 ng/mL
(6.0 ng/mL)
Lopes et al., 2019 [15]
Square wave voltammetry (SWV)Graphene oxide–ferrocene nanofilm0.1~1000 ng/mL
(0.03 ng/mL)
Erika et al., 2019 [41]
Electrochemiluminescent (ECL)Graphene
composite (G/mRub)
1.0 fg/mL~10 ng/mL
(0.38 fg/mL)
Zhao et al., 2019 [19]
Interdigitated electrode (IDE)Polypyrrole/carbon nanotube0~300 ng/mL
(28 ng/mL)
Ferreira et al., 2020 [20]
Field effect transistor (FET)Silicon nanowire1 ag/mL~1 ng/mL
(0.2529 ag/mL)
This work
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Hu, J.; Li, Y.; Zhang, X.; Wang, Y.; Zhang, J.; Yan, J.; Li, J.; Zhang, Z.; Yin, H.; Wei, Q.; et al. Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. Biosensors 2024, 14, 461. https://doi.org/10.3390/bios14100461

AMA Style

Hu J, Li Y, Zhang X, Wang Y, Zhang J, Yan J, Li J, Zhang Z, Yin H, Wei Q, et al. Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. Biosensors. 2024; 14(10):461. https://doi.org/10.3390/bios14100461

Chicago/Turabian Style

Hu, Jiawei, Yinglu Li, Xufang Zhang, Yanrong Wang, Jing Zhang, Jiang Yan, Junjie Li, Zhaohao Zhang, Huaxiang Yin, Qianhui Wei, and et al. 2024. "Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645" Biosensors 14, no. 10: 461. https://doi.org/10.3390/bios14100461

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop